BS PD IEC TR 61869-100-2017 Instrument transformers Guidance for application of current transformers in power system protection《仪表互感器 保护电力系统的电流互感器应用指南 》.pdf
《BS PD IEC TR 61869-100-2017 Instrument transformers Guidance for application of current transformers in power system protection《仪表互感器 保护电力系统的电流互感器应用指南 》.pdf》由会员分享,可在线阅读,更多相关《BS PD IEC TR 61869-100-2017 Instrument transformers Guidance for application of current transformers in power system protection《仪表互感器 保护电力系统的电流互感器应用指南 》.pdf(140页珍藏版)》请在麦多课文档分享上搜索。
1、Instrument transformers Part 100: Guidance for application of current transformers in power system protection PD IEC/TR 61869-100:2017 BSI Standards Publication WB11885_BSI_StandardCovs_2013_AW.indd 1 15/05/2013 15:06National foreword This Published Document is the UK implementation of IEC/TR 61869-
2、 100:2017. The UK participation in its preparation was entrusted to Technical Committee PEL/38, Instrument transformers. A list of organizations represented on this committee can be obtained on request to its secretary. This publication does not purport to include all the necessary provisions of a c
3、ontract. Users are responsible for its correct application. The British Standards Institution 2017. Published by BSI Standards Limited 2017 ISBN 978 0 580 84959 6 ICS 17.220.20 Compliance with a British Standard cannot confer immunity from legal obligations. This Published Document was published und
4、er the authority of the Standards Policy and Strategy Committee on 28 February 2017. Amendments/corrigenda issued since publication Date Text affected PUBLISHED DOCUMENT PD IEC/TR 61869-100:2017 IEC TR 61869-100 Edition 1.0 2017-01 TECHNICAL REPORT Instrument transformers Part 100: Guidance for appl
5、ication of current transformers in power system protection INTERNATIONAL ELECTROTECHNICAL COMMISSION ICS 17.220.20 ISBN 978-2-8322-3808-0 Registered trademark of the International Electrotechnical Commission Warning! Make sure that you obtained this publication from an authorized distributor. colour
6、 inside PD IEC/TR 61869-100:2017 2 IEC TR 61869-100:2017 IEC 2017 CONTENTS FOREWORD . 7 INTRODUCTION . 9 1 Scope 10 2 Normative references 10 3 Terms and definitions and abbreviations 10 3.1 Terms and definitions 10 3.2 Index of abbreviations . 12 4 Responsibilities in the current transformer design
7、 process. 14 4.1 History 14 4.2 Subdivision of the current transformer design process 14 5 Basic theoretical equations for transient designing 15 5.1 Electrical circuit 15 5.1.1 General . 15 5.1.2 Current transformer . 18 5.2 Transient behaviour 20 5.2.1 General . 20 5.2.2 Fault inception angle . 22
8、 5.2.3 Differential equation 23 6 Duty cycles 25 6.1 Duty cycle C O . 25 6.1.1 General . 25 6.1.2 Fault inception angle . 27 6.1.3 Transient factor K tfand transient dimensioning factor K td. 28 6.1.4 Reduction of asymmetry by definition of the minimum current inception angle . 50 6.2 Duty cycle C O
9、 C O 53 6.2.1 General . 53 6.2.2 Case A:No saturation occurs until t . 54 6.2.3 Case B:Saturation occurs between t aland t . 56 6.3 Summary 58 7 Determination of the transient dimensioning factor K tdby numerical calculation 61 7.1 General . 61 7.2 Basic circuit 61 7.3 Algorithm 62 7.4 Calculation m
10、ethod . 63 7.5 Reference examples . 64 8 Core saturation and remanence . 69 8.1 Saturation definition for common practice . 69 8.1.1 General . 69 8.1.2 Definition of the saturation flux in the preceding standard IEC 60044-1 69 8.1.3 Definition of the saturation flux in IEC 61869-2 71 8.1.4 Approach
11、“5 % Factor 5” . 72 8.2 Gapped cores versus non-gapped cores . 73 8.3 Possible causes of remanence 75 9 Practical recommendations 79 9.1 Accuracy hazard in case various PR class definitions for the same core . 79 PD IEC/TR 61869-100:2017IEC TR 61869-100:2017 IEC 2017 3 9.2 Limitation of the phase di
12、splacement and of the secondary loop time constant T sby the transient dimensioning factor K tdfor TPY cores 79 10 Relations between the various types of classes . 80 10.1 Overview. 80 10.2 Calculation of e.m.f. at limiting conditions . 80 10.3 Calculation of the exciting (or magnetizing) current at
13、 limiting conditions 81 10.4 Examples 81 10.5 Minimum requirements for class specification . 82 10.6 Replacing a non-gapped core by a gapped core 82 11 Protection functions and correct CT specification 83 11.1 General . 83 11.2 General application recommendations 83 11.2.1 Protection functions and a
14、ppropriate classes . 83 11.2.2 Correct CT designing in the past and today . 85 11.3 Overcurrent protection: ANSI code: (50/51/50N/51N/67/67N); IEC symbol: I . 87 11.3.1 Exposition 87 11.3.2 Recommendation . 89 11.3.3 Example 89 11.4 Distance protection: ANSI codes: 21/21N, IEC code: Z 89 11.4.1 Expo
15、sition 89 11.4.2 Recommendations . 91 11.4.3 Examples. 91 11.5 Differential protection 98 11.5.1 Exposition 98 11.5.2 General recommendations . 99 11.5.3 Transformer differential protection (87T) 99 11.5.4 Busbar protection: Ansi codes (87B) 104 11.5.5 Line differential protection: ANSI codes (87L)
16、(Low impedance) 107 11.5.6 High impedance differential protection . 109 Annex A (informative) Duty cycle C O software code. 128 Annex B (informative) Software code for numerical calculation of K td130 Bibliography 135 Figure 1 Definition of the fault inception angle . 12 Figure 2 Components of prote
17、ction circuit 16 Figure 3 Entire electrical circuit 17 Figure 4 Primary short circuit current . 18 Figure 5 Non-linear flux of L ct19 Figure 6 Linearized magnetizing inductance of a current transformer . 20 Figure 7 Simulated short circuit behaviour with non-linear model . 21 Figure 8 Three-phase sh
18、ort circuit behaviour . 23 Figure 9 Composition of flux 24 Figure 10 Short circuit current for two different fault inception angles 26 Figure 11 maxas the curve of the highest flux values 26 Figure 12 Primary current curves for the 4 cases for 50 Hz and = 70 . 27 Figure 13 Four significant cases of
19、short circuit currents with impact on magnetic saturation of current transformers . 28 PD IEC/TR 61869-100:2017 4 IEC TR 61869-100:2017 IEC 2017 Figure 14 Relevant time ranges for calculation of transient factor 31 Figure 15 Occurrence of the first flux peak depending on T p, at 50 Hz . 32 Figure 16
20、 Worst-case angle tf,max as function of T pand t al. 33 Figure 17 Worst-case fault inception angle tf,maxas function of T pand t al. 34 Figure 18 K tf,maxcalculated with worst-case fault inception angle max34 Figure 19 Polar diagram with K tf,maxand tf,max. 35 Figure 20 Determination of K tfin time
21、range 1 . 40 Figure 21 Primary current curves for 50Hz, T p= 1 ms, max = 166 for t al= 2 ms . 41 Figure 22 worst-case fault inception angles for 50Hz, T p= 50 ms and T s= 61 ms . 42 Figure 23 transient factor for different time ranges . 43 Figure 24 K tfin all time ranges for T s= 61 ms at 50 Hz wit
22、h t alas parameter 44 Figure 25 Zoom of Figure 24 44 Figure 26 Primary current for a short primary time constant . 45 Figure 27 K tfvalues for a short primary time constant 46 Figure 28 Short circuit currents for various fault inception angles . 47 Figure 29 Transient factors for various fault incep
23、tion angles (example) 48 Figure 30 Worst-case fault inception angles for each time step (example for 50 Hz) 48 Figure 31 Primary current for two different fault inception angles (example for 16,67 Hz) 49 Figure 32 Transient factors for various fault inception angles (example for 16,67 Hz) 50 Figure
24、33 Worst-case fault inception angles for every time step (example for 16,67 Hz) 50 Figure 34 Fault occurrence according to Warrington 51 Figure 35 estimated distribution of faults over several years 52 Figure 36 Transient factor K tfcalculated with various fault inception angles 53 Figure 37 Flux co
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BSPDIECTR618691002017INSTRUMENTTRANSFORMERSGUIDANCEFORAPPLICATIONOFCURRENTTRANSFORMERSINPOWERSYSTEMPROTECTION

链接地址:http://www.mydoc123.com/p-397678.html