BS PD CLC TR 62541-2-2010 OPC Unified Architecture nPart 2 Security model《OPC统一架构 第2部分 安全模型》.pdf
《BS PD CLC TR 62541-2-2010 OPC Unified Architecture nPart 2 Security model《OPC统一架构 第2部分 安全模型》.pdf》由会员分享,可在线阅读,更多相关《BS PD CLC TR 62541-2-2010 OPC Unified Architecture nPart 2 Security model《OPC统一架构 第2部分 安全模型》.pdf(36页珍藏版)》请在麦多课文档分享上搜索。
1、raising standards worldwide NO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAW BSI Standards Publication OPC Unified Architecture Part 2: Security model PD CLC/TR 62541-2:2010National foreword This Published Document is the UK implementation of CLC/TR 62541-2:2010. It is identica
2、l to IEC/TR 62541-2:2010. The UK participation in its preparation was entrusted to Technical Committee AMT/7, Industrial communications: process measurement and control, including fieldbus. A list of organizations represented on this committee can be obtained on request to its secretary. This public
3、ation does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application. BSI 2010 ISBN 978 0 580 64158 9 ICS 25.040.40; 35.100.01; 35.200; 35.240.50 Compliance with a British Standard cannot confer immunity from legal obligations. This Publishe
4、d Document was published under the authority of the Standards Policy and Strategy Committee on 3 2010. Amendments/corrigendum issued since publication Date Text affected PUBLISHED DOCUMENT PD CLC/TR 62541-2:2010 1 October TECHNICAL REPORT CLC/TR 62541-2 RAPPORT TECHNIQUE TECHNISCHER BERICHT August 2
5、010 CENELEC European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Management Centre: Avenue Marnix 17, B - 1000 Brussels 2010 CENELEC - All rights of exploitation in any form and by any means reserved
6、worldwide for CENELEC members. Ref. No. CLC/TR 62541-2:2010 E ICS 25.040.40; 35.100.01 English version OPC unified architecture - Part 2: Security model (IEC/TR 62541-2:2010) Architecture unifie OPC - Partie 2: Modle de scurit (CEI/TR 62541-2:2010) OPC Unified Architecture - Teil 2: Modell fr die IT
7、-Sicherheit (IEC/TR 62541-2:2010) This Technical Report was approved by CENELEC on 2010-06-25. CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Irelan
8、d, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom. CLC/TR 62541-2:2010 - 2 - Foreword The text of the Technical Report IEC/TR 62541-2:2010, prepared by SC 65E, Devices and integrat
9、ion in enterprise systems, of IEC TC 65, Industrial-process measurement, control and automation, was submitted to vote and was approved by CENELEC as CLC/TR 62541-2 on 2010-06-25. Annex ZA has been added by CENELEC. _ Endorsement notice The text of the Technical Report IEC/TR 62541-2:2010 was approv
10、ed by CENELEC as a Technical Report without any modification. In the official version, for Bibliography, the following notes have to be added for the standards indicated: IEC 62541-3 NOTE Harmonized as EN 62541-3. IEC 62541-4 NOTE Harmonized as EN 62541-4. IEC 62541-5 NOTE Harmonized as EN 62541-5.
11、IEC 62541-6 NOTE Harmonized as EN 62541-6. _ PD CLC/TR 62541-2:2010 - 3 - CLC/TR 62541-2:2010 Annex ZA (normative) Normative references to international publications with their corresponding European publications The following referenced documents are indispensable for the application of this docume
12、nt. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. NOTE When an international publication has been modified by common modifications, indicated by (mod), the relevant EN/HD applies. Public
13、ation Year Title EN/HD Year IEC/TR 62541-1 2010 OPC unified architecture - Part 1: Overview and concepts CLC/TR 62541-1 2010 IEC 62541 Series OPC unified architecture EN 62541 Series PD CLC/TR 62541-2:2010 2 TR 62541-2 IEC:2010(E) CONTENTS INTRODUCTION.6 1 Scope.7 2 Normative references .7 3 Terms,
14、definitions, abbreviations and conventions7 3.1 Terms and definitions 7 3.2 Abbreviations and symbols11 3.3 Conventions concerning security model figures .11 4 OPC UA Security architecture 11 4.1 OPC UA security environment .11 4.2 Security objectives 12 4.2.1 General .12 4.2.2 Authentication .13 4.
15、2.3 Authorization .13 4.2.4 Confidentiality .13 4.2.5 Integrity.13 4.2.6 Auditability 13 4.2.7 Availability.13 4.3 Security threats to OPC UA systems .13 4.3.1 General .13 4.3.2 Message flooding 13 4.3.3 Eavesdropping 14 4.3.4 Message spoofing .14 4.3.5 Message alteration 14 4.3.6 Message replay .14
16、 4.3.7 Malformed messages.15 4.3.8 Server profiling15 4.3.9 Session hijacking.15 4.3.10 Rogue server.15 4.3.11 Compromising user credentials15 4.4 OPC UA relationship to site security16 4.5 OPC UA security architecture16 4.6 Security policies 18 4.7 Security profiles 18 4.8 User authorization .19 4.
17、9 User authentication .19 4.10 Application authentication .19 4.11 OPC UA security related services19 4.12 Auditing.20 4.12.1 General .20 4.12.2 Single client and server .21 4.12.3 Aggregating server 21 4.12.4 Aggregation through a non-auditing server 22 4.12.5 Aggregating server with service distri
18、bution.23 5 Security reconciliation 24 5.1 Reconciliation of threats with OPC UA security mechanisms .24 PD CLC/TR 62541-2:2010TR 62541-2 IEC:2010(E) 5 5.1.1 General .24 5.1.2 Message flooding 24 5.1.3 Eavesdropping 25 5.1.4 Message spoofing .25 5.1.5 Message alteration 25 5.1.6 Message replay .25 5
19、.1.7 Malformed messages.26 5.1.8 Server profiling26 5.1.9 Session hijacking.26 5.1.10 Rogue server.26 5.1.11 Compromising user credentials26 5.2 Reconciliation of objectives with OPC UA security mechanisms 26 5.2.1 General .26 5.2.2 Authentication .27 5.2.3 Authorization .27 5.2.4 Confidentiality .2
20、7 5.2.5 Integrity.27 5.2.6 Auditability 28 5.2.7 Availability.28 6 Implementation considerations .28 6.1 General .28 6.2 Appropriate timeouts .28 6.3 Strict message processing.28 6.4 Random number generation 29 6.5 Special and reserved packets29 6.6 Rate limiting and flow control 29 Bibliography30 F
21、igure 1 OPC UA network model .12 Figure 2 OPC UA security architecture.17 Figure 3 Simple servers .21 Figure 4 Aggregating servers.22 Figure 5 Aggregation with a non-auditing server 23 Figure 6 Aggregate server with service distribution 24 PD CLC/TR 62541-2:2010 6 TR 62541-2 IEC:2010(E) INTRODUCTION
22、 This technical report introduces security concepts for OPC Unified Architecture as specified by IEC 62541. This technical report and specification are a result of an analysis and design process to develop a standard interface to facilitate the development of applications by multiple vendors that in
23、ter-operate seamlessly together. PD CLC/TR 62541-2:2010TR 62541-2 IEC:2010(E) 7 OPC UNIFIED ARCHITECTURE Part 2: Security Model 1 Scope This part of IEC 62541 describes the OPC Unified Architecture (OPC UA) security model. It describes the security threats of the physical, hardware and software envi
24、ronments in which OPC UA is expected to run. It describes how OPC UA relies upon other standards for security. It gives an overview of the security features that are specified in other parts of the OPC UA specification. It references services, mappings, and profiles that are specified normatively in
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BSPDCLCTR6254122010OPCUNIFIEDARCHITECTURENPART2SECURITYMODELOPC 统一 架构 部分 安全 模型 PDF

链接地址:http://www.mydoc123.com/p-397603.html