《BS PD CLC TR 50473-2007 Recommendations for dimensional co-ordination between enclosures and built-in devices for rail fixing for household and similar installations《家用和类似.pdf》由会员分享,可在线阅读,更多相关《BS PD CLC TR 50473-2007 Recommendations for dimensional co-ordination between enclosures and built-in devices for rail fixing for household and similar installations《家用和类似.pdf(12页珍藏版)》请在麦多课文档分享上搜索。
1、PUBLISHED DOCUMENT PD CLC/TR 50473:2007 Recommendations for dimensional co-ordination between enclosures and built-in devices for rail fixing for household and similar installations ICS 29.060.10 PD CLC/TR 50473:2007 This Published Document was published under the authority of the Standards Policy a
2、nd Strategy Committee on 29 June 2007 BSI 2007 ISBN 978 0 580 52988 7 National foreword This Published Document was published by BSI. It is the UK implementation of CLC/TR 50473:2007. It supersedes PD 6590:1996 which is withdrawn. The UK participation in its preparation was entrusted by Technical Co
3、mmittee PEL/23, Electrical accessories, to Subcommittee PEL/23/1, Circuit breakers and similar equipment for household use. A list of organizations represented on this committee can be obtained on request to its secretary. This publication does not purport to include all the necessary provisions of
4、a contract. Users are responsible for its correct application. Amendments issued since publication Amd. No. Date Comments TECHNICAL REPORT CLC/TR 50473 RAPPORT TECHNIQUE TECHNISCHER BERICHT May 2007 CENELEC European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electr
5、otechnique Europisches Komitee fr Elektrotechnische Normung Central Secretariat: rue de Stassart 35, B - 1050 Brussels 2007 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members. Ref. No. CLC/TR 50473:2007 E ICS 29.060.10 Supersedes R023-001:1995Eng
6、lish version Recommendations for dimensional co-ordination between enclosures and built-in devices for rail fixing for household and similar installations This Technical Report was approved by CENELEC on 2006-01-21. CENELEC members are the national electrotechnical committees of Austria, Belgium, Bu
7、lgaria, Cyprus, the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom. Foreword Report R
8、023-001:1995 was prepared by the Technical Committee CENELEC TC 23E, Circuit breakers and similar devices for household and similar applications. It has been drawn up on the basis of the decisions taken by TC 23E at their 9 thmeeting on 8 thand 9 thNovember 1994, where the document CLC/TC23E(Sec)38
9、and the relevant comments of the National Committees were examined. This Report was approved by CENELEC on 1995-03-06. Following BT decision D124/C048 and TC 23E advice, an updated version of R023-001:1995 was circulated for voting for conversion into a Technical Report in accordance with the Intern
10、al Regulations, Part 2, Subclause 11.4.3.3 and was approved by CENELEC as CLC/TR 50473 on 2006-01-21. This Technical Report supersedes R023-001:1995. CLC/TR 50473:2007 2 1 Scope The purpose of this report is to give recommendations of the co-ordination of dimensions between enclosures and built-in d
11、evices for rail fixing for household or similar installations by listing the principal overall and related mounting dimensions, the rated current of a single device not exceeding 125 A. Examples of these devices are: MCBs, RCDs switches, fuse-systems, indicating lamps, relays, socket- outlets, timin
12、g switches, etc. Compliance with this document does not preclude the need for compliance with other relevant specifications. This document needs not apply to type tested and partially type tested assemblies which are covered by other specifications. The means of fixing envisaged in this document are
13、 mounting rails. Other possible means of fixing may be used but are not covered by these recommendations. NOTE The only criterion chosen in this document for co-ordination of dimensions has been the geometry of the devices. When selecting the enclosure, other criteria should be taken into account, e
14、.g. the rated current of the devices. 2 Normative references EN 60715:2001, Dimensions of low-voltage switchgear and controlgear - Standardized mounting on rails for mechanical support of electrical devices in switchgear and controlgear installations (IEC 60715:1981 + A1:1995) 3 Definitions For the
15、purpose of this Technical Report the following definitions apply: 3.1 module (m) a basic single block 3.2 device a modular block that is not intended to be split into independent units 4 Mounting rails The mounting rails used shall be of the 35 mm “Top hat” type according to EN 60715 or an equivalen
16、t mounting means, obtained e.g. by moulding or pressing. NOTE Other types of mounting rails may be used but are not necessarily covered by these recommendations. Recommendations for dimensional co-ordination of devices designed to be fixed on two mounting rails are under consideration. Examples are
17、given in Annex A. 5 Dimensions of devices relevant to mounting The principal dimensions necessary to co-ordinate the built-in devices with the enclosures are given in Figure 1. CLC/TR 50473:2007 3 5.1 Width “l” The width of a device shall be l = n (m 0 5 , 0 + ) mm where n = 0,5 or 1 or 1,5 or 2 or
18、2,5 or 3 or 3,5 or 4 m = 12,5 or 17,5 mm NOTE The preferred value for future designs is m = 17,5 mm. 5.2 Height of a given device “h” h 1and h 2of a given device (see Figure 1a) need not to be equal. h 1maxor h 2max , whichever is the greater, shall be chosen from the series 45 55 75 100 125 mm. NOT
19、E 1 The maximum height (h 1+ h 2 ) must not exceed twice the values chosen. NOTE 2 The means for fixing or removing the device to and from the rail are not taken into account. 5.3 Height of front projection “d” (see Figure 1a) Up to and including a value h 1or h 2 whichever is the greater of 45 mm t
20、he height d of the front projections shall be 45 0,5 mm. For values of h 1or h 2greater than 45 mm the front projection “d” shall have one of the following values: 45 mm and 80 mm, with a tolerance of 0,5 mm. NOTE The preferred value for future designs is d = 45 mm. 5.4 Depth dimensions q 1 , q 2and
21、 q 3(see Figure 1a) The depth dimensions are given in Table 1. Table 1 Depth dimensions q 1maxmm q 2minmm q 3max bmm 55 60 70 44 a50 c92,5 70 55 57 92,5 80 64 66 100 76 84 100 aPreferred value. bWhere more than one value of q 3maxis shown for a value of q 1maxand q 2min ; the appropriate value is a
22、function of the design “family” of the device. cPreferred value of q 2min = 52 mm. CLC/TR 50473:2007 4 6 Distance Y between parallel mounting rails (see Figure 1b) The distance Y between centre lines of parallel rails shall be Y = X 25 mm where X = 4 or 5 or 6 or The tolerance shall not exceed 0,5 m
23、m for Y 125 mm (X 5) and 1,0 mm for Y 125 (X 5). For boards or panels with 3 or more rows the cumulative tolerance shall not exceed 2 mm. NOTE 1 Multiplier 4 is intended for boards or panels containing rows made up exclusively of accessories, indicator lights, fuses, etc. For rows containing switchi
24、ng devices the minimum value is 5. NOTE 2 The distance from the highest and lowest rail to the top or bottom face respectively of the board is not considered. NOTE 3 It is the responsibility of the manufacturer of the board to choose the appropriate Y-value(s). NOTE 4 In a given board values of Y di
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BSPDCLCTR504732007RECOMMENDATIONSFORDIMENSIONALCOORDINATIONBETWEENENCLOSURESANDBUILTINDEVICESFORRAILFIXINGFORHOUSEHOLDANDSIMILARINSTALLATIONS

链接地址:http://www.mydoc123.com/p-397569.html