BS ISO TR 11925-1-1999 Reaction to fire tests - Ignitability of building products subjected to direct impingement of flame - Guidance on ignitability《对火焰试验的反应 直接接触火焰的建筑产品的.pdf
《BS ISO TR 11925-1-1999 Reaction to fire tests - Ignitability of building products subjected to direct impingement of flame - Guidance on ignitability《对火焰试验的反应 直接接触火焰的建筑产品的.pdf》由会员分享,可在线阅读,更多相关《BS ISO TR 11925-1-1999 Reaction to fire tests - Ignitability of building products subjected to direct impingement of flame - Guidance on ignitability《对火焰试验的反应 直接接触火焰的建筑产品的.pdf(38页珍藏版)》请在麦多课文档分享上搜索。
1、BRITISH STANDARD BS ISO TR 11925-1:1999 Reaction to fire tests Ignitability of building products subjected to direct impingement of flame Part 1: Guidance on ignitability ICS 13.220.50BSISOTR11925-1:1999 This British Standard, having been prepared under the directionof the Health and Environment Sec
2、tor Committeewas published underthe authority of the Standards Committee and comesinto effect on 15 October 1999 BSI 04-2000 ISBN 0 580 35277 3 National foreword This British Standard reproduces verbatim ISO TR 11925-1:1999 and implements it as the UK national standard. The UK participation in its p
3、reparation was entrusted by Technical Committee FSH/21, Reaction to fire tests, to Subcommittee FSH/21/2, Ignitability tests, which has the responsibility to: aid enquirers to understand the text; present to the responsible international/European committee any enquiries on the interpretation, or pro
4、posals for change, and keep the UK interests informed; monitor related international and European developments and promulgate them in the UK. A list of organizations represented on this subcommittee can be obtained on request to its secretary. Cross-references The British Standards which implement i
5、nternational publications referred to in this document may be found in the BSI Standards Catalogue under the section entitled “International Standards Correspondence Index”, or by using the “Find” facility of the BSI Standards Electronic Catalogue. A British Standard does not purport to include all
6、the necessary provisions of a contract. Users of British Standards are responsible for their correct application. Compliance with a British Standard does not of itself confer immunity from legal obligations. Summary of pages This document comprises a front cover, an inside front cover, pages i and i
7、i, theISO/TR title page, pages ii to iv, pages 1 to 28, an inside back cover and aback cover. This standard has been updated (see copyright date) and may have had amendments incorporated. This will be indicated in the amendment table on the inside front cover. Amendments issued since publication Amd
8、. No. Date CommentsBSISOTR11925-1:1999 BSI 04-2000 i Contents Page National foreword Inside front cover Foreword iii Text of ISO/TR 11925-1 1ii blankBSISOTR11925-1:1999 ii BSI 04-2000 Contents Page Foreword ii Introduction 1 1 Scope 2 2 References 2 3 Typical“real fire” ignition sources 2 3.1 Genera
9、l 2 3.2 Characteristics of flame sources 3 3.3 Characteristics of electrical sources 4 3.4 Characteristics of radiative sources 5 4 Factors affecting ignitability tests 5 4.1 General 5 4.2 Type of heat source 5 4.2.1 Gas burners 6 4.2.2 Liquid pool fires 6 4.2.3 Solid fuels 6 4.2.4 Radiative sources
10、 6 4.2.5 Electrical sources 7 4.2.6 Smouldering sources 7 4.3 Size 7 4.4 Location 7 4.5 Physical and chemical response of exposed material 8 5 Ignitability tests 8 5.1 Radiative sources 8 5.1.1 Electrical 8 5.1.2 Gaseous 9 5.2 Flame sources 10 5.2.1 Diffusion flames 10 5.2.2 Premixed flames 10 5.3 C
11、omparison of ignition sources of ISO/TC 92/SC 1 tests 11 5.3.1 Characteristics of radiative sources 11 5.3.2 Characteristics of ISO 11925 and ISO 9705 flame sources 11 6 Models for the piloted ignition of solids 12 6.1 Introduction and general review 12 6.2 Power laws and the critical irradiance for
12、 ignition 13 6.3 Thermal thickness and substrate effects 13 6.4 Variables affecting ignitability 14 6.5 Comparisons of experimental methods 14 6.5.1 Radiative sources 14 6.5.2 Flame sources 14 Annex A Guidelines for the development of ignition source for fire tests 28 Annex B Bibliography Inside bac
13、k cover Figure 1 a) Specimen support framework and radiator cone 15 Figure 1 b) Radiator cone 16 Figure 2 Cone heater 17 Figure 3 Schematic of apparatus with ignition specimen 18 Figure 4 Apparatus specified in ISO 5458-2 19 Figure 5 a) Intermediate-scale calorimeter 20 Figure 5 b) Heat shield 21 Fi
14、gure 6 Radiant panel apparatus (ISO 9239) 22 Figure 7 Burner for ignition sources E and F (ISO 11925-3) 23BSISOTR11925-1:1999 BSI 04-2000 iii Page Figure 8 Recommended sand burner (ISO 9705) 24 Figure 9 Alternative ignition source (ISO 9705) 25 Figure 10 Burner (ISO 11925-2) 26 Figure 11 Premixed bu
15、rner for sources G and H (ISO 11925-3) 27 Table 1 4 Table 2 11 Table 3 11BSISOTR11925-1:1999 iv BSI 04-2000 Foreword ISO (the International Organization for Standardization) is a worldwide federation of national standards bodies (ISO member bodies). The work of preparing International Standards is n
16、ormally carried out through ISO technical committees. Each member body interested in a subject for which a technical committee has been established has the right to be represented on that committee. International organizations, governmental and non-governmental, in liaison with ISO, also take part i
17、n the work. ISO collaborates closely with the International Electrotechnical Commission (IEC) on all matters of electrotechnical standardization. Technical Reports are drafted in accordance with the rules given in the ISO/IEC Directives, Part 3. The main task of technical committees is to prepare In
18、ternational Standards, but in exceptional circumstances, a technical committee may propose the publication of a Technical Report of one of the following types: type 1, when the required support cannot be obtained for the publication of an International Standard, despite repeated efforts; type 2, whe
19、n the subject is still under technical development or where for any other reason there is the future but not immediate possibility of an agreement on an International Standard; type 3, when a technical committee has collected data of a different kind from that which is normally published as an Inter
20、national Standard (“state of the art”, for example). Technical Reports of types 1 and 2 are subject to review within three years of publication, to decide whether they can be transformed into International Standards. Technical Reports of type 3 do not necessarily have to be reviewed until the data t
21、hey provide are considered to be no longer valid or useful. ISO/TR 11925-1, which is a Technical Report of type 3, was prepared by Technical Committee ISO/TC 92, Fire safety, Subcommittee SC 1, Reaction to fire. ISO/TR 11925 consists of the following parts, under the general title Reaction to fire t
22、ests Ignitability of building products subjected to direct impingement of flame: Part 1: Guidance on ignitability; Part 2: Single flame source test; Part 3: Multi-source test.BSISOTR11925-1:1999 BSI 04-2000 1 Introduction Ignitability of materials is of basic importance when fire hazard is analysed
23、because of two reasons: First, at the initiation of a fire some object or local area is ignited, and second, during the fire growth period ignitability is an essential factor in fire spread to the other parts of a room or compartment. In buildings the structural, lining and furnishing materials are
24、solids, which require external heating to achieve flaming combustion. The ignition condition can be characterized by the minimum surface temperature at which the flow of volatiles is sufficient for sustained flaming. However, the difference in these temperatures between materials is not large. Hence
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BSISOTR1192511999REACTIONTOFIRETESTSIGNITABILITYOFBUILDINGPRODUCTSSUBJECTEDTODIRECTIMPINGEMENTOFFLAMEGUIDANCEONIGNITABILITY

链接地址:http://www.mydoc123.com/p-397002.html