BS ISO IEC 29109-9-2011 Information technology Conformance testing methodology for biometric data interchange formats defined in ISO IEC 19794 Vascular image data《信息技术 ISO.pdf
《BS ISO IEC 29109-9-2011 Information technology Conformance testing methodology for biometric data interchange formats defined in ISO IEC 19794 Vascular image data《信息技术 ISO.pdf》由会员分享,可在线阅读,更多相关《BS ISO IEC 29109-9-2011 Information technology Conformance testing methodology for biometric data interchange formats defined in ISO IEC 19794 Vascular image data《信息技术 ISO.pdf(18页珍藏版)》请在麦多课文档分享上搜索。
1、raising standards worldwide NO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAW BSI Standards Publication BS ISO/IEC 29109-9:2011 Information technology Conformance testing methodology for biometric data interchange formats defined in ISO/IEC 19794 Part 9: Vascular image dataBS IS
2、O/IEC 29109-9:2011 BRITISH STANDARD National foreword This British Standard is the UK implementation of ISO/IEC 29109-9:2011. The UK participation in its preparation was entrusted to Technical Committee IST/44, Biometrics. A list of organizations represented on this committee can be obtained on requ
3、est to its secretary. This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application. BSI 2011 ISBN 978 0 580 68470 8 ICS 35.040 Compliance with a British Standard cannot confer immunity from legal obligations. This British
4、Standard was published under the authority of the Standards Policy and Strategy Committee on 31 July 2011. Amendments issued since publication Date Text affectedBS ISO/IEC 29109-9:2011Reference number ISO/IEC 29109-9:2011(E) ISO/IEC 2011INTERNATIONAL STANDARD ISO/IEC 29109-9 First edition 2011-07-15
5、 Information technology Conformance testing methodology for biometric data interchange formats defined in ISO/IEC 19794 Part 9: Vascular image data Technologies de linformation Mthodologie dessai de conformit pour les formats dinterchange de donnes biomtriques dfinis dans lISO/CEI 19794 Partie 9: Do
6、nnes dimages vasculaires BS ISO/IEC 29109-9:2011 ISO/IEC 29109-9:2011(E) COPYRIGHT PROTECTED DOCUMENT ISO/IEC 2011 All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying
7、and microfilm, without permission in writing from either ISO at the address below or ISOs member body in the country of the requester. ISO copyright office Case postale 56 CH-1211 Geneva 20 Tel. + 41 22 749 01 11 Fax + 41 22 749 09 47 E-mail copyrightiso.org Web www.iso.org Published in Switzerland
8、ii ISO/IEC 2011 All rights reservedBS ISO/IEC 29109-9:2011 ISO/IEC 29109-9:2011(E) ISO/IEC 2011 All rights reserved iiiForeword ISO (the International Organization for Standardization) and IEC (the International Electrotechnical Commission) form the specialized system for worldwide standardization.
9、National bodies that are members of ISO or IEC participate in the development of International Standards through technical committees established by the respective organization to deal with particular fields of technical activity. ISO and IEC technical committees collaborate in fields of mutual inte
10、rest. Other international organizations, governmental and non-governmental, in liaison with ISO and IEC, also take part in the work. In the field of information technology, ISO and IEC have established a joint technical committee, ISO/IEC JTC 1. International Standards are drafted in accordance with
11、 the rules given in the ISO/IEC Directives, Part 2. The main task of the joint technical committee is to prepare International Standards. Draft International Standards adopted by the joint technical committee are circulated to national bodies for voting. Publication as an International Standard requ
12、ires approval by at least 75 % of the national bodies casting a vote. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. ISO and IEC shall not be held responsible for identifying any or all such patent rights. ISO/IEC 29109-9 was pre
13、pared by Joint Technical Committee ISO/IEC JTC 1, Information technology, Subcommittee SC 37, Biometrics. ISO/IEC 29109 consists of the following parts, under the general title Information technology Conformance testing methodology for biometric data interchange formats defined in ISO/IEC 19794: Par
14、t 1: Generalized conformance testing methodology Part 2: Finger minutiae data Part 4: Finger image data Part 5: Face image data Part 6: Iris image data Part 7: Signature/sign time series data Part 8: Finger pattern skeletal data Part 9: Vascular image data Part 10: Hand geometry silhouette data The
15、following parts are under preparation: Part 14: DNA data Finger pattern spectral data, signature/sign processed dynamic data and voice data will form the subjects of future parts. BS ISO/IEC 29109-9:2011 ISO/IEC 29109-9:2011(E) iv ISO/IEC 2011 All rights reservedIntroduction ISO/IEC 19794-9:2007 spe
16、cifies a data record interchange format for exchange of human vascular image data among systems within a Common Biometric Exchange Formats Framework (CBEFF) data structure. The data stored in a vascular data record often contains the metadata storing the subject-specific and image- specific, as well
17、 as the technology being used. This part of ISO/IEC 29109 establishes tests for checking the correctness of the binary record. When vascular image data is transmitted among systems, it can be interfered with by noise due to the transmission line. The received data might be incorrect during the excha
18、nge process. Therefore, there is a need to conduct conformance tests of commercial products to determine whether the data conform to ISO/IEC 19794-9:2007 before using the data for other purposes. Vascular biometric technology is emerging or is under development by many research organizations. The va
19、scular image resources are also being used by many vendors, who have utilized the vascular technology as a recognition or verification method in their systems. Currently, however, there is no standardized method for conducting conformance tests of vascular image data that supports ISO/IEC 19794-9:20
20、07 during the exchange of vascular image data among systems. Application developers and implementers of different organizations can interpret ISO/IEC 19794-9:2007 in different manners. Therefore, a standardized conformance testing methodology is necessary for achieving interoperability among impleme
21、ntations. This part of ISO/IEC 29109 supports those applications that require use of vascular image data according to ISO/IEC 19794-9:2007. It defines a testing methodology to ensure conformance of a vendors application or service to ISO/IEC 19794-9:2007. Thus, it is intended to: establish elements
22、of the conformance testing methodology framework that are specific to the vascular image-based data record requirements of ISO/IEC 19794-9:2007 conformance testing; define requirements and guidelines for specifying conformance test suites and related test methods for measuring conformity of products
23、 and services to the vascular image data record requirements of ISO/IEC 19794-9:2007; and define testing and reporting procedures to be followed before, during, and after conformance testing. This part of ISO/IEC 29109 is applicable to the development and use of conformity test method specifications
24、, conformity test suites for ISO/IEC 19794-9:2007 records, and conformance testing programs for ISO/IEC 19794-9:2007 conformant products. It is intended primarily for use by testing organizations, but can be applied by developers and users of test method specifications and test method implementation
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BSISOIEC2910992011INFORMATIONTECHNOLOGYCONFORMANCETESTINGMETHODOLOGYFORBIOMETRICDATAINTERCHANGEFORMATSDEFINEDINISOIEC19794VASCULARIMAGEDATA

链接地址:http://www.mydoc123.com/p-396715.html