BS ISO 8600-5-2005 Optics and photonics - Medical endoscopes and endotherapy devices - Determination of optical resolution of rigid endoscopes with optics《光学和光子学 医用内窥镜和内疗器.pdf
《BS ISO 8600-5-2005 Optics and photonics - Medical endoscopes and endotherapy devices - Determination of optical resolution of rigid endoscopes with optics《光学和光子学 医用内窥镜和内疗器.pdf》由会员分享,可在线阅读,更多相关《BS ISO 8600-5-2005 Optics and photonics - Medical endoscopes and endotherapy devices - Determination of optical resolution of rigid endoscopes with optics《光学和光子学 医用内窥镜和内疗器.pdf(10页珍藏版)》请在麦多课文档分享上搜索。
1、BRITISH STANDARD BS ISO 8600-5:2005 Optics and photonics Medical endoscopes and endotherapy devices Part 5: Determination of optical resolution of rigid endoscopes with optics ICS 11.040.55; 37.020 BS ISO 8600-5:2005 This British Standard was published under the authority of the Standards Policy and
2、 Strategy Committee on 1 August 2005 BSI 1 August 2005 ISBN 0 580 46432 6 National foreword This British Standard reproduces verbatim ISO 8600-5:2005 and implements it as the UK national standard. The UK participation in its preparation was entrusted to Technical Committee LBI/33, Microscopes, which
3、 has the responsibility to: aid enquirers to understand the text; present to the responsible international/European committee any enquiries on the interpretation, or proposals for change, and keep UK interests informed; monitor related international and European developments and promulgate them in t
4、he UK. A list of organizations represented on this committee can be obtained on request to its secretary. Cross-references The British Standards which implement international publications referred to in this document may be found in the BSI Catalogue under the section entitled “International Standar
5、ds Correspondence Index”, or by using the “Search” facility of the BSI Electronic Catalogue or of British Standards Online. This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application. Compliance with a British Standard d
6、oes not of itself confer immunity from legal obligations. Summary of pages This document comprises a front cover, an inside front cover, the ISO title page, pages ii and iii, a blank page, pages 1 to 3 and a back cover. The BSI copyright notice displayed in this document indicates when the document
7、was last issued. Amendments issued since publication Amd. No. Date CommentsReference number ISO 8600-5:2005(E) INTERNATIONAL STANDARD ISO 8600-5 First edition 2005-03-15 Optics and photonics Medical endoscopes and endotherapy devices Part 5: Determination of optical resolution of rigid endoscopes wi
8、th optics Optique et photonique Endoscopes mdicaux et dispositifs dendothrapie Partie 5: Dtermination de la rsolution optique des endoscopes optiques rigides BS ISO 8600-5:2005iiiii Foreword ISO (the International Organization for Standardization) is a worldwide federation of national standards bodi
9、es (ISO member bodies). The work of preparing International Standards is normally carried out through ISO technical committees. Each member body interested in a subject for which a technical committee has been established has the right to be represented on that committee. International organizations
10、, governmental and non-governmental, in liaison with ISO, also take part in the work. ISO collaborates closely with the International Electrotechnical Commission (IEC) on all matters of electrotechnical standardization. International Standards are drafted in accordance with the rules given in the IS
11、O/IEC Directives, Part 2. The main task of technical committees is to prepare International Standards. Draft International Standards adopted by the technical committees are circulated to the member bodies for voting. Publication as an International Standard requires approval by at least 75 % of the
12、member bodies casting a vote. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. ISO shall not be held responsible for identifying any or all such patent rights. ISO 8600-5 was prepared by Technical Committee ISO/TC 172, Optics and p
13、hotonics, Subcommittee SC 5, Microscopes and endoscopes. ISO 8600 consists of the following parts, under the general title Optics and photonics Medical endoscopes and endotherapy devices: Part 1: General requirements Part 2: Particular requirements for rigid bronchoscopes Part 3: Determination of fi
14、eld of view and direction of view of endoscopes with optics Part 4: Determination of maximum width of insertion portion Part 5: Determination of optical resolution of rigid endoscopes with optics Part 6: Vocabulary BS ISO 8600-5:2005blank 1 Optics and photonics Medical endoscopes and endotherapy dev
15、ices Part 5: Determination of optical resolution of rigid endoscopes with optics 1 Scope This part of ISO 8600 specifies a test method for determining the optical resolution of endoscopes for type testing. It is applicable to rigid endoscopes with optics designed for use in the practice of medicine
16、for type testing. It is not applicable to endoscopes having a fibre-optic or opto-electronic imaging system. 2 Terms and definitions For the purposes of this document, the following terms and definitions apply. 2.1 working distance d distance between object and distal end of endoscope NOTE For the p
17、urposes of the test specified in this part of ISO 8600, the “object” will be the resolution target specified in 3.1.1. 2.2 optical resolution r(d) maximum number of line pairs per millimetre which can be just perceived at a given working distance d of the endoscope 2.3 angular resolution smallest an
18、gle whose vertex is at the distal window surface of the endoscope at which a line pair at a given working distance d can just be identified; it is calculated as follows: 1 arctan drd 2.4 maximum image height 2.4.1 maximum image height circular field of view radius of the field circle BS ISO 8600-5:2
19、005BS ISO 8600-5:2005 2 2.4.2 maximum image height non-circular field of view radius of a circle which circumscribes the maximum field of view EXAMPLE If the field of view is rectangular, the maximum image height is half of the diagonal. 2.5 on-axis resolution resolution at the centre of the image (
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BSISO860052005OPTICSANDPHOTONICSMEDICALENDOSCOPESANDENDOTHERAPYDEVICESDETERMINATIONOFOPTICALRESOLUTIONOFRIGIDENDOSCOPESWITHOPTICS

链接地址:http://www.mydoc123.com/p-395890.html