T-11 Air Permeability Investigation.ppt
《T-11 Air Permeability Investigation.ppt》由会员分享,可在线阅读,更多相关《T-11 Air Permeability Investigation.ppt(25页珍藏版)》请在麦多课文档分享上搜索。
1、T-11 Air Permeability Investigation,Eric Blissmer 26 August 2011,Disclaimer,We will NOT identify any specific details of which supplier(s) that are involved with this investigationWe will NOT address specific root cause and corrective actions taken by any supplier(s)We will NOT engage in any discuss
2、ions related to proprietary process or information,Outline,Problem Statement Background Information Root Cause Investigation Measurement Systems Analysis Raw material results Final canopy (MIL-DTL-6645) results Conclusions,Problem Statement,While inspecting finished canopies in accordance with MIL-D
3、TL-6645 per contract requirements, approximately 10% of T-11 main and T-11 reserve canopies built in May, June and July of 2011 were found out of tolerance for air permeability,MIL-DTL-6645 (T-11 Mod) Air Perm. Inspection,Yellow = Center sectionX = Inspection points (single reading),Background Infor
4、mation,Investigation started with industry notification of suspect lots of material based upon high air permeability readings at a prime contractor on finished T-11 canopiesIncreased sampling was initiated on completed canopies and out of tolerance canopies were identifiedSome out of tolerance canop
5、ies used materials from lots not originally suspect Led to investigation of all canopies and components built with PIA-C-44378 Type IV and Type VI,Root Cause Investigation,Worked closely with Government and Supplier(s) on identifying the root causeProcess anomalies were identified which correlated w
6、ith the high readings (4.0 cfm to 7.0 cfm) being found at Airborne SystemsCorrective actions have been implemented but have yet to be verifiedBut the data revealed there are additional causes of variation,Inspection Results,Inspection of over 500 T-11 systems identified over 10% Main and 10% reserve
7、s out of toleranceCombination of high readings and high averages,Typical Causes of Variation,Standard variation process in control Typical spread or scatter of observations as seen by a process under controlSpecial cause variation -out of control Unusual occurrences that are not normally part of the
8、 processMeasurement variation Repeatability = same part same operator Reproducibility = same part different operators,Out of control,Different Variation in Air Permeability,Notice the single out of control point on this canopy Avg = 3.43 and resulting CpK = .15Now re-run without the single high read
9、ing resulting in very little difference, New Avg = 3.38 and New CpK = .24Proves there is another issue on top of the special causes!,Measurement System Analysis,Measurement accounts for only 2.96% (target 10%) But measurement variation SD = 0.23 which consumes a large % of the tolerance,Variation of
10、 Raw (on roll) goods,Data = single reading every 20 yards directly taken off the rollResults Average = 1.99 Std Dev = 0.46 Estimates 1.4% of material with readings over 3.0 cfm,Government - Before June 2011 - Avg =2.10 cfm Std dev = .43 Data - After June 2011 - Avg = 2.41 cfm Std dev = .53,Variation
11、 of Finished Canopy,Same lot of material (Lot 6) Ten canopies per MIL-DTL-6645Results Average = 2.64 Std Dev = .31 Process CpK = 1.01 indicates marginally capable,Study Summary,Average increase over 0.5 cfm from manufacturing T-11Since June, increase in average 0.31 cfmIf we estimate the out of tole
12、rance yardage based upon 2.41 cfm and known variation = 10.1%With this variation need average to be near 1.4 cfm,Conclusions,Several causes for out of tolerance issues Special cause related to processing Standard variation too high if overall averages close to specification upper limits Possible tha
13、t air permeability increases slightly more than anticipated (needs further investigation) Due to either T-11 configuration Or manufacturing process Or sampling process on T-11 Or changes in manufacturing processes since MIL-DTL-6645 created Inspection process also creates additional variability,Need
14、 to continue to evaluate tolerance allowances between raw material and final canopy specifications,BACK UP SLIDES,Fabric air permeability is a measure of how much air flows through the canopy fabric Air flows through the fabric when there is a higher pressure on one side (inside the canopy) compared
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。