IEEE 2010-2012 en Recommended Practice for Neurofeedback Systems《神经反馈系统用IEEE推荐性操作规程》.pdf
《IEEE 2010-2012 en Recommended Practice for Neurofeedback Systems《神经反馈系统用IEEE推荐性操作规程》.pdf》由会员分享,可在线阅读,更多相关《IEEE 2010-2012 en Recommended Practice for Neurofeedback Systems《神经反馈系统用IEEE推荐性操作规程》.pdf(35页珍藏版)》请在麦多课文档分享上搜索。
1、IEEE Recommended Practice for Neurofeedback SystemsSponsored by the Standards Committee IEEE 3 Park Avenue New York, NY 10016-5997 USA 29 June 2012 IEEE Engineering in Medicine and Biology SocietyIEEE Std 2010-2012IEEE Std 2010-2012 IEEE Recommended Practice for Neurofeedback Systems Sponsor Standar
2、ds Committee of the IEEE Engineering in Medicine and Biology Society Approved 14 May 2012 IEEE-SA Standards Board Abstract: A detailed set of documentation requirements is proposed. The detailed requirements for the documentation of neurofeedback instruments and software to provide quality and avail
3、ability of information to users are specified. Keywords: biofeedback, biofeedback assessment, biofeedback equipment, biofeedback instrumentation, biofeedback software, biofeedback training ,(neurofeedback, neurofeedback assessment, neurofeedback equipment, neurofeedback instrumentation, neurofeedbac
4、k software, neurofeedback training xThe Institute of Electrical and Electronics Engineers, Inc. 3 Park Avenue, New York, NY 10016-5997, USA Copyright 2012 by The Institute of Electrical and Electronics Engineers, Inc. All rights reserved. Published 29 June 2012. Printed in the United States of Ameri
5、ca. IEEE is a registered trademark in the U.S. Patent +1 978 750 8400. Permission to photocopy portions of any individual standard for educational classroom use can also be obtained through the Copyright Clearance Center. Notice to users Laws and regulations Users of IEEE Standards documents should
6、consult all applicable laws and regulations. Compliance with the provisions of any IEEE Standards document does not imply compliance to any applicable regulatory requirements. Implementers of the standard are responsible for observing or referring to the applicable regulatory requirements. IEEE does
7、 not, by the publication of its standards, intend to urge action that is not in compliance with applicable laws, and these documents may not be construed as doing so. Copyrights This document is copyrighted by the IEEE. It is made available for a wide variety of both public and private uses. These i
8、nclude both use, by reference, in laws and regulations, and use in private self-regulation, standardization, and the promotion of engineering practices and methods. By making this document available for use and adoption by public authorities and private users, the IEEE does not waive any rights in c
9、opyright to this document. Updating of IEEE documents Users of IEEE Standards documents should be aware that these documents may be superseded at any time by the issuance of new editions or may be amended from time to time through the issuance of amendments, corrigenda, or errata. An official IEEE d
10、ocument at any point in time consists of the current edition of the document together with any amendments, corrigenda, or errata then in effect. In order to determine whether a given document is the current edition and whether it has been amended through the issuance of amendments, corrigenda, or er
11、rata, visit the IEEE-SA Website at http:/standards.ieee.org/index.html or contact the IEEE at the address listed previously. For more information about the IEEE Standards Association or the IEEE standards development process, visit IEEE-SA Website at http:/standards.ieee.org/index.html. Errata Errat
12、a, if any, for this and all other standards can be accessed at the following URL: http:/standards.ieee.org/findstds/errata/index.html. Users are encouraged to check this URL for errata periodically. Patents Attention is called to the possibility that implementation of this standard may require use o
13、f subject matter covered by patent rights. By publication of this standard, no position is taken by the IEEE with respect to the existence or validity of any patent rights in connection therewith. If a patent holder or patent applicant has filed a statement of assurance via an Accepted Letter of Ass
14、urance, then the statement is listed on the IEEE-SA Website at http:/standards.ieee.org/about/sasb/patcom/patents.html. Letters of Assurance may indicate whether the Submitter is willing or unwilling to grant licenses under patent rights without compensation or under reasonable rates, with reasonabl
15、e terms and conditions that are demonstrably free of any unfair discrimination to applicants desiring to obtain such licenses. Copyright 2012 IEEE. All rights reserved. ivCopyright 2012 IEEE. All rights reserved. vEssential Patent Claims may exist for which a Letter of Assurance has not been receive
16、d. The IEEE is not responsible for identifying Essential Patent Claims for which a license may be required, for conducting inquiries into the legal validity or scope of Patents Claims, or determining whether any licensing terms or conditions provided in connection with submission of a Letter of Assu
17、rance, if any, or in any licensing agreements are reasonable or non-discriminatory. Users of this standard are expressly advised that determination of the validity of any patent rights, and the risk of infringement of such rights, is entirely their own responsibility. Further information may be obta
18、ined from the IEEE Standards Association. Copyright 2012 IEEE. All rights reserved. viParticipants At the time this recommended practice was completed, the Neurofeedback (EEG Biofeedback) Systems Working Group had the following membership: Thomas Collura, Chair Howard Lightstone, Vice Chair Sara Agu
19、el Michael Hoffman Cynthia Kerson Alan Pope Marc Saab Klaus Schellhorn Nancy Wigton The following members of the entity balloting committee voted on this recommended practice. Balloters may have voted for approval, disapproval, or abstention. Association for Applied Psychophysiology and Biofeedback
20、(AAPB) BrainMaster Technologies, Inc. EEG Education referring to operant conditioning process. amplifier: A device that draws power from a source other than the input signal and produces as an output an enlarged reproduction of the essential features of its input (Graf B5). analog to digital convert
21、er (A/D): A device that changes an analog signal to a digital signal of corresponding magnitude through discretization (Laplante B11). artifact: Any distortion of the electroencephalography signal from any physiologic source other than the brain or any non-physiologic source that may interfere with
22、the interpretation of the signal. average value (P-P): The “average value” traditionally used in neurofeedback is actually the “equivalent peak-to-peak” voltage value assuming that the signal being measured is a sine wave. The normal method of calculation is to sum the absolute voltage values of eac
23、h signal sample, divide by the number of samples, and 2 2 to get the peak-to-peak equivalent. baseline: Status of brain activity when not engaged in a feedback/operant conditioning process. characterization: The extraction of significant features from the EEG waveforms. client: Person who is receivi
24、ng neurofeedback (i.e., is connected to a neurofeedback system); person from whom electroencephalography signal is being acquired. clinician: Person responsible for ordering (prescribing) as well as interpreting and making clinical decisions about neurofeedback; oversees the neurofeedback session. T
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- IEEE20102012ENRECOMMENDEDPRACTICEFORNEUROFEEDBACKSYSTEMS 神经 反馈 系统 IEEE 推荐 操作规程 PDF

链接地址:http://www.mydoc123.com/p-1248569.html