VA 09 23 00-2011 GYPSUM PLASTERING.pdf
《VA 09 23 00-2011 GYPSUM PLASTERING.pdf》由会员分享,可在线阅读,更多相关《VA 09 23 00-2011 GYPSUM PLASTERING.pdf(10页珍藏版)》请在麦多课文档分享上搜索。
1、10-11 09 23 00 - 1 SECTION 09 23 00 GYPSUM PLASTERING SPEC WRITER NOTE: Delete between /-/ if not applicable to project. Also delete any other item or paragraph not applicable in the section and renumber the paragraphs. PART 1 - GENERAL 1.1 DESCRIPTION This section specifies metal and gypsum lathing
2、 and gypsum plaster. 1.2 RELATED WORK A. Steel framing members for attachment of plaster bases: Section 05 40 00, COLD-FORMED METAL FRAMING, and Section 09 22 16, NON-STRUCTURAL METAL FRAMING. B. Room finish schedule: Section 09 06 00, SCHEDULE FOR FINISHESS. C. Cement plaster: Section 09 24 00, POR
3、TLAND CEMENT PLASTERING. D. Veneer plaster: Section 09 26 00, VENEER PLASTERING. E. Lead lined lath: Section 13 49 00, RADIATION PROTECTION. 1.3 TERMINOLOGY A. Definitions and description of terms shall be in accordance with ASTM C11, C841, and C842 and as specified. B. Underside of Structure Overhe
4、ad: In spaces where steel trusses or bar joists are shown, the underside of structure overhead is the underside of the floor or roof construction supported by beams, trusses, and bar joists. C. Self-furring Lath: Metal plastering bases having dimples or crimps designed to hold the plane of the back
5、of the lath 6 to 10 mm (1/4 to 3/8 inch) away from the plane of the solid backing. D. Solid Backing or Solid Bases: Concrete, masonry, sheathing, rigid insulation, and similar materials to which plaster is directly applied. E. Wet Areas: Areas of a building where cyclic or continuous exposure to ver
6、y humid or wet conditions, or in which a dew point condition may occur in the plaster. Dew point conditions occur frequently in such areas as laundries, natatoriums, cart and dish washing spaces, hydrotherapy, kitchens, bathing or shower rooms and similar areas. 1.4 SUBMITTALS A. Submit in accordanc
7、e with Section 01 33 23, SHOP DRAWINGS, PRODUCT DATA, AND SAMPLES. B. Shop Drawings: 1. Details of floating interior angle unrestrained construction. 2. Details of assembly and anchorage of lath and accessories. Provided by IHSNot for ResaleNo reproduction or networking permitted without license fro
8、m IHS-,-,-10-11 09 23 00 - 2 C. Manufacturers Literature and Data: 1. Accessories for plaster, each type. 2. Metal plaster bases, each type. 3. Fasteners. 4. Bonding compounds, including application instructions. 5. Admixtures, including mixing and application instructions. D. Manufacturers certific
9、ates: 1. Gypsum plaster. 2. Keenes cement. E. Samples: Accessories for plaster, each type, not less than 150 mm (six inches) long. SPEC WRITER NOTE: Request plaster sample where color is specified or special finish is required, and where required to match existing special finish conditions. Specify
10、a size to suit requirements, 150 by 300 mm (6 by 12 inches) minimum. Panel showing finish coat, _ by _ mm (inches). 1.5 DELIVERY, STORAGE, AND PROTECTION ASTM C841 and C842. 1.6 PROJECT CONDITIONS Maintain work areas at a minimum temperature of 13C (55F) for not less than one week prior to applicati
11、on of plaster, during application of plaster and until plaster is completely dry. 1.7 APPLICABLE PUBLICATIONS A. The publications listed below form a part of this specification to the extent referenced. The publications are referenced in the text by basic designation only. B. American Society for Te
12、sting And Materials (ASTM): A641-09 Zinc-Coated (Galvanized) Carbon Steel Wire C11-10 . Terminology Relating to Gypsum and Related Building Materials and Systems. C28-10 . Gypsum Plasters C35-01 (R2009) . Inorganic Aggregates For Use in Gypsum Plaster C61-00(R2006) Gypsum Keenes Cement C206-03(R2009
13、) . Finishing Hydrated Lime C472-99(R2009) . Physical Testing of Gypsum, Gypsum Plaster and Gypsum Concrete C631-09 Bonding Compounds for Interior Gypsum Plastering C841-03(R2008) . Installation of Interior Lathing and Furring C842-05(R2010) . Application of Interior Gypsum Plaster C847-10 Metal Lat
14、h Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-10-11 09 23 00 - 3 C1002-07 . Steel Self-Piercing Tapping Screws for the Application of Gypsum Panel Products or Metal Plaster Bases to Wood Studs or Steel Studs D3678-97(R2008) Rigid Poly (Vinyl Chlo
15、ride) (PVC) Interior-Profile Extrusions C. Commercial Item Description (CID): A-A-55615 Shield, Expansion; (Wood Screw and Log Bolt Self Threading Anchor) PART 2 - PRODUCTS SPEC WRITER NOTE: Make material requirements agree with applicable requirements specified in the referenced Applicable Publicat
16、ions. Update and specify only that which applies to the project. 2.1 PLASTERING BASES (LATH) A. Expanded Metal: ASTM C847, except as modified by ASTM C841 and this specification. B. Gypsum Lath: 1. 10 mm (3/8 inch) thick. 2. Type X for fire rated assemblies. 2.2 GYPSUM PLASTERS A. Base and Finish co
17、ats ASTM C28 and ASTM C842, except as otherwise specified. 1. Compressive strength of base coat for high-strength gypsum and Keenes cement finish coat plaster; 25 Mpa (2800 psi) when tested in accordance with ASTM C472. 2. Compressive strength of finish coat (when fully dry) of high-strength gypsum
18、plaster; 35 Mpa (5,000 psi) when tested in accordance with ASTM C472. B. Keenes Cement for Finish Coats: ASTM C61. 2.3 LIME ASTM C206, Type S. 2.4 AGGREGATES A. ASTM C35, natural sand, except grade aggregates in accordance with “TABLE 1“, except sand for Keenes Cement Finish Coat, 100 percent passin
19、g a No. 30 sieve. B. Vermiculite and perlite aggregates are not permitted, except where required for fire rated assemblies. 2.5 BONDING COMPOUND (FOR INTERIOR WORK) ASTM C631, except water re-emulsifiable compound is prohibited. Provided by IHSNot for ResaleNo reproduction or networking permitted wi
20、thout license from IHS-,-,-10-11 09 23 00 - 4 2.6 ACCESSORIES FOR GYPSUM PLASTER ASTM C841. 2.7 FASTENERS A. Tie wire, screws, clips, and other fasteners ASTM C841, except as otherwise specified. B. Fasteners for securing metal plastering bases shall have heads, or be through washers large enough to
21、 engage two strands of the metal plastering base. C. For fire rated construction type and size as used in fire rated test. D. Screws: ASTM C1002. E. Expansion Shields: CID A-A-55615, of the Type and Class applicable. SPEC WRITER NOTE: Coordinate with Section 09 30 13, CERAMIC TILING for type of sett
22、ing bed required for ceramic tile. Generally in wet areas glass fiber reinforced concrete backer board is used and is mandatory for showers. Gypsum plaster or gypsum board may be used for adhesive applied ceramic tile in areas not considered wet. Coordinate with Sections 09 06 00, SCHEDULE FOR FINIS
23、HES, Section 09 22 16, NON-STRUCTURAL METAL FRAMING and Section 09 30 13, CERAMIC TILING to clearly define substrate for ceramic tile finish. Portland cement plaster is required for walls and ceilings above ceramic wall tile in showers and similar wet areas. PART 3 EXECUTION 3.1 APPLYING LATH BASES
24、A. In accordance with ASTM C841, except as otherwise specified or shown. B. Use metal plastering bases where plaster is required on partitions, ceilings and furring /, where required for setting ceramic title in adhesive on gypsum plaster / and for light troughs, beams and other curved or irregular
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- VA0923002011GYPSUMPLASTERINGPDF