1、08-11 02 83 33.13 - 1 SECTION 02 83 33.13 LEAD-BASED PAINT REMOVAL AND DISPOSAL SPEC WRITER NOTE: Delete between / _ / if not applicable to project. Also delete any other item or paragraph not applicable in the section and renumber the paragraphs. PART 1 - GENERAL 1.1 DESCRIPTION This section specif
2、ies abatement and disposal of lead-based paint (LBP) and controls needed to limit occupational and environmental exposure to lead hazards. 1.2 RELATED WORK A. Section 02 82 11, TRADITIONAL ASBESTOS ABATEMENT. B. Section 02 41 00, DEMOLITION. C. Section 09 91 00, PAINTING. 1.3 APPLICABLE PUBLICATIONS
3、 A. The publications listed below form a part of this specification to the extent referenced. The publications are referred to in the text by basic designation only. B. Code of Federal Regulations (CFR): CFR 29 Part 1910 . Occupational Safety and Health Standards CFR 29 Part 1926 . Safety and Health
4、 Regulations for Construction CFR 40 Part 148 Hazardous Waste Injection Restrictions CFR 40 Part 260 Hazardous Waste Management System: General CFR 40 Part 261 Identification and Listing of Hazardous Waste CFR 40 Part 262 Standards Applicable to Generators of Hazardous Waste CRF 40 Part 263 Standard
5、s Applicable to Transporters of Hazardous Waste CFR 40 Part 264 Standards for Owners and Operations of Hazardous Waste Treatment, Storage, and Disposal Facilities CFR 40 Part 265 Interim Status Standards for Owners and Operators of Hazardous Waste Treatment, Storage, and Disposal Facilities CFR 40 P
6、art 268 Land Disposal Restrictions CFR 49 Part 172 Hazardous Material Table, Special Provisions, Hazardous Material Communications, Emergency Response Information, and Training Requirements CFR 49 Part 178 Specifications for Packaging Provided by IHSNot for ResaleNo reproduction or networking permit
7、ted without license from IHS-,-,-08-11 02 83 33.13 - 2 C. National Fire Protection Association (NFPA): NFPA 701-2004 Methods of Fire Test for Flame-Resistant Textiles and Films D. National Institute for Occupational Safety And Health (NIOSH) NIOSH OSHA Booklet 3142 Lead in Construction E. Underwrite
8、rs Laboratories (UL) UL 586-1996 (Rev 2009) . High-Efficiency, Particulate, Air Filter Units F. American National Standards Institute Z9.2-2006 Fundamentals Governing the Design and Operation of Local Exhaust Systems Z88.6-2006 . Respiratory Protection 1.4 DEFINITIONS A. Action Level: Employee expos
9、ure, without regard to use of respirations, to an airborne concentration of lead of 30 micrograms per cubic meter of air averaged over an 8-hour period. As used in this section, ”30 micrograms per cubic meter of air“ refers to the action level. B. Area Monitoring: Sampling of lead concentrations wit
10、hin the lead control area and inside the physical boundaries which is representative of the airborne lead concentrations which may reach the breathing zone of personnel potentially exposed to lead. C. Physical Boundary: Area physically roped or partitioned off around an enclosed lead control area to
11、 limit unauthorized entry of personnel. As used in this section, “inside boundary“ shall mean the same as “outside lead control area.“ D. Certified Industrial Hygienist (CIH): As used in this section, refers to an Industrial Hygienist employed by the Contractor and is certified by the American Board
12、 of Industrial Hygiene in comprehensive practice. E. Change Rooms and Shower Facilities: Rooms within the designated physical boundary around the lead control area equipped with separate storage facilities for clean protective work clothing and equipment and for street clothes which prevent cross- c
13、ontamination. F. Competent Person: A person capable of identifying lead hazards in the work area and is authorized by the contractor to take corrective action. G. Decontamination Room: Room for removal of contaminated personal protective equipment (PPE). H. Eight-Hour Time Weighted Average (TWA): Ai
14、rborne concentration of lead averaged over an 8-hour workday to which an employee is exposed. I. High Efficiency Particulate Air (HEPA) Filter Equipment: HEPA filtered vacuuming equipment with a UL 586 filter system capable of collecting and retaining lead-contaminated paint dust. A high efficiency
15、Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-08-11 02 83 33.13 - 3 particulate filter means 99.97 percent efficient against 0.3 micron size particles. J. Lead: Metallic lead, inorganic lead compounds, and organic lead soaps. Excluded from this def
16、inition are other organic lead compounds. K. Lead Control Area: An enclosed area or structure with full containment to prevent the spread of lead dust, paint chips, or debris of lead-containing paint removal operations. The lead control area is isolated by physical boundaries to prevent unauthorized
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- VA028333132011LEADBASEDPAINTREMOVALANDDISPOSALPDF

链接地址:http://www.mydoc123.com/p-1074673.html