1、PALLADIUM, GOLD AND POTASSIUM INSILICA CATALYST BY ICP-AESUOP Method 916-93SCOPEThis method is for determining palladium, gold and potassium in fresh silica catalyst by InductivelyCoupled Plasma-Atomic Emission Spectrometry (ICP-AES). The method is suitable for the concentrationranges of 0.2 to 1 ma
2、ss-% palladium, 0.1 to 0.5 mass-% gold and 1 to 5 mass-% potassium. Catalystscontaining more than 1% alumina cannot be analyzed by this method.OUTLINE OF METHODA representative sample of fresh whole pill catalyst is obtained and ground according to UOP Method918. A portion of the ground sample is fu
3、med with hydrofluoric and sulfuric acids and the residue isdissolved in hydrochloric and nitric acids. Scandium is added as an internal standard. The sample solution isaspirated into a computer controlled ICP-AES along with a matrix-matched standard. Concentrations aredetermined by comparison of the
4、 sample emission ratios to the computer-generated standard calibrationcurves. Results are reported on a volatile-free basis at 700C, following duplicate loss on ignition (LOI)determinations by UOP Method 909.APPARATUSReferences to catalog numbers and suppliers are included as a convenience to the me
5、thod user. Othersuppliers may be used.Balance, electronic, readability 0.1-mg, 200-g capacityBalance, electronic, top-loading, readability 0.01-g, 2100-g capacityBeaker, borosilicate glass, 400-mLBeakers, Teflon (TFE), 250-mL, Fisher Scientific, Cat. No. 02-593-5BBottle, narrow mouth, round, amber g
6、lass, 237-mL, with molded plastic conical polyethylene lined cap,Fisher Scientific, Cat. No. 03-320-6CBottle, polyethylene, right-to-know safety wash, distilled water, 500-mL, Fisher Scientific, Cat. No. 03-409-11EIT IS THE USERS RESPONSIBILITY TO ESTABLISH APPROPRIATE PRECAUTIONARY PRACTICES AND TO
7、DETERMINE THE APPLICABILITY OF REGULATORY LIMITATIONS PRIOR TO USE. EFFECTIVE HEALTH ANDSAFETY PRACTICES ARE TO BE FOLLOWED WHEN UTILIZING THIS PROCEDURE. FAILURE TO UTILIZE THISPROCEDURE IN THE MANNER PRESCRIBED HEREIN CAN BE HAZARDOUS. MATERIAL SAFETY DATA SHEETS(MSDS) OR EXPERIMENTAL MATERIAL SAF
8、ETY DATA SHEETS (EMSDS) FOR ALL OF THE MATERIALS USED INTHIS PROCEDURE SHOULD BE REVIEWED FOR SELECTION OF THE APPROPRIATE PERSONAL PROTECTIONEQUIPMENT (PPE). COPYRIGHT 1993 UOP LLCALL RIGHTS RESERVEDUOP Methods are available through ASTM International, 100 Barr Harbor Drive, PO Box C700, West Consh
9、ohocken PA 19428-2959,United States. The Methods may be obtained through the ASTM website, www.astm.org, or by contacting Customer Service atserviceastm.org, 610.832.9555 FAX, or 610.832.9585 PHONE.2 of 10916-93Buret, weighing, 10-mL, Kimble No. 17200-F10, Scientific Products, Cat. No. B9366-10Cylin
10、der, graduated, borosilicate glass, Class A, 1000-mL, Fisher Scientific, Cat. No. 08-553DCylinder, graduated, polypropylene, 25-mL, Fisher Scientific, Cat. No. 08-572-6BFlask, Kjeldahl, 100-mL, Fisher Scientific, Cat. No. 10-110CFlasks, volumetric, Class A, 100- and 1000-mL, Fisher Scientific, Cat.
11、Nos. 10-210-5C and -5G,respectivelyFunnel, filter, 58 angle bowl, short stem, 75-mm diameter, Fisher Scientific, Cat. No. 10-322EHot plate-stirrer, digital, Dataplate, 9-positions, Scientific Products, Cat. No. H2185-6Inductively Coupled Plasma-Atomic Emission Spectrometer, computer controlled, havi
12、ng a bandpass of0.010 nm (FWHM) or better, and covering the wavelength range specified in Table 1. The instrumentmust have the ability to use internal standards and perform background corrections, and must measurethe internal standard response concurrently with each element response. A Perkin-Elmer
13、Plasma 2000spectrometer with a corrosion resistant sample introduction system, or its equivalent, is required.Petri dish, Fisher Scientific, Cat. No. 08-747FPipetter, motorized, digital, Rainin, Cat. No. EP-10mL, with portable power pack, Cat. No. 6100-080,rapid charge stand, Cat. No. 6101-049 and p
14、ipet tips, Cat. No. RC-10mLPipetter, repeater, 5-, 10- and 25-mL, Fisher Scientific, Cat. Nos. 13-683-10B, -10C and -10F,respectivelyRegulator, argon, two-stage, high purity, Matheson Gas Products, Model 3104-580Regulator, nitrogen, two-stage, high purity, Matheson Gas Products, Model 3104-580Scoop,
15、 weighing, 20-g capacity, nickel alloy, Fisher Scientific, Cat. No. 01-914-38Spatula, Scoopula, 150-mm, Fisher Scientific, Cat. No. 14-357Stirring bars, magnetic, borosilicate glass, 6-mm OD x 21-mm, and 9.55-mm OD x 25.4-mm, ScientificProducts, Cat. Nos. S8313-31 and -33, respectivelyStirring bars,
16、 magnetic, Teflon, 38-mm, Fisher Scientific, Cat. No. 14-511-64Thermometer, surface, with temperature probe, Omega Engineering, Cat. Nos. HH81 and 88108K,respectivelyTongs, beakerWatch glass, Pyro-quartz, triple-rib, 90-mm diameter, rim to center (curvature) height approximately 25mm, Pyromatics, Ca
17、t. No. PI-7206REAGENTS AND MATERIALSAll reagents shall conform to the specifications established by the Committee on Analytical Reagents ofthe American Chemical Society, when such specifications are available, unless otherwise specified.References to water mean deionized or distilled water, except w
18、here noted.References to catalog numbers and suppliers are included as a convenience to the method user. Othersuppliers may be used.Acetone, 99.5% minimum purity3 of 10916-93Argon, 99.995% minimum purity, ICP feed gasGold wire, 0.25-mm diameter, high purity, 99.998%, Aesar, Cat. No. 10967Hydrochlori
19、c acid, concentrated, 37%Hydrochloric acid, 1:1. Add 500 mL of concentrated hydrochloric acid, measured in a graduatedcylinder, to an equal volume of water in a volumetric flask and mix.Hydrofluoric acid, concentrated, 48-51%Hydrogen peroxide, concentrated, 30%Nitric acid, concentrated, 70%Nitrogen,
20、 99.99% minimum purity, water/oil free, ICP optics purge gasPalladium wire, 0.25-mm diameter, high purity, 99.997%, Aesar, Cat. No. 10962Potassium standard, custom grade standard, 10-mg/mL, Inorganic Ventures, Inc., Cat. No. CGK10-5.The relative density information on the label is needed for prepara
21、tion of the Reference Standard on amass basis.Scandium standard, custom grade standard, 1000-g/mL, Inorganic Ventures, Inc., Cat. No. CGSC1-5Sulfuric acid, concentrated, 98%Sulfuric acid, 1:1. Carefully, and with ice-cooling, pour 500 mL of concentrated sulfuric acid into 500mL of water, mix and all
22、ow to cool. The mixture may be stored indefinitely in a well stoppered bottleor flask.PROCEDUREAll subsequent steps involving handling and heating of concentrated acids or acid solutions must beperformed in a fume hood.Preparation of Calibration StandardsPalladium Standard Solution (1-mg/g)1. Weigh
23、1.0 g of 99.997% palladium wire to the nearest 0.1 mg.2. Transfer the palladium wire into a 100-mL Kjeldahl flask and add a small borosilicate glass magneticstir bar.3. Add 25 mL of hydrochloric acid and 10 mL of nitric acid to the flask. Place the flask in a 400-mLbeaker. Treatment of the palladium
24、 is conducted at ambient temperature until evolution of chlorine has subsided. If allowed to sit overnight, the palladium may dissolve without heating.4. Place the flask and beaker on a stirring hot plate and heat to a gentle boil while stirring slowly.5. Maintain the solution volume at approximatel
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- UOP9161993PALLADIUMGOLDANDPOTASSIUMINSILICACATALYSTBYICPAESPDF

链接地址:http://www.mydoc123.com/p-1074565.html