《UL SUBJECT 2571-2007 OUTLINE OF INVESTIGATION FOR IRRIGATION FEEDER CONTROL AND SIGNAL CABLES (Issue 1)《灌溉机械用供电、控制和信号电缆调查大纲 发布编号 1》.pdf》由会员分享,可在线阅读,更多相关《UL SUBJECT 2571-2007 OUTLINE OF INVESTIGATION FOR IRRIGATION FEEDER CONTROL AND SIGNAL CABLES (Issue 1)《灌溉机械用供电、控制和信号电缆调查大纲 发布编号 1》.pdf(10页珍藏版)》请在麦多课文档分享上搜索。
1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULDecember 5, 20071SUBJECT 2571OUTLINE OF INVESTIGATIONFORIRRIGATION FEEDER, CONTROL, AND SIGNAL CABLESISSUE NUMBER: 1DECEMBER 5, 2007Summary of TopicsThis is the First Issue of the Outline of Inve
2、stigation for Irrigation Feeder,Control, and Signal Cables. Irrigation feeder, control, and signal cablesare intended for direct burial to supply power, signals, or guidance toirrigation machines.The UL Foreword is no longer located within the UL Standard. For informationconcerning the use and appli
3、cation of the requirements contained in thisStandard, the current version of the UL Foreword is located onULStandardsInfoNet at: http:/ 2007 UNDERWRITERS LABORATORIES INC.UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULDECEMBER 5, 2007SUBJECT
4、25712No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULCONTENTSINTRODUCTION1 Scope .42 Units of Measurement .43 Components 44 Undated References 5CONSTRUCTION5 Materials and Workmanship 56 Conductors .57 Conductor Assembly 68
5、 Inner Jacket (Optional) 69 Outer Jacket .6PERFORMANCE10 General .711 Environmental Exposure Tests 711.1 Exposures 711.2 Tests on exposed samples .9MARKINGS12 General .913 Tag, Reel, or Carton Markings .1014 Date of Manufacture 10DECEMBER 5, 2007 SUBJECT 2571 3UL COPYRIGHTED MATERIAL NOT AUTHORIZED
6、FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULINTRODUCTION1 Scope1.1 This Outline covers the requirements for irrigation feeder, control, and signal cables rated 300 or 600V, 60 or 75C. The insulated-conductor sizes are 18 AWG 250 kcmil, solid or stranded copper. Thecables are in
7、tended for direct burial and are used to:a) Supply power to irrigation machines (feeder cable),b) Send power and/or signals to irrigation machines (control cable), and/orc) Supply guidance to irrigation machines (signal cable).These cables are not intended for indoor use or for any existing uses cov
8、ered by the National ElectricalCode (NEC), ANSI/NFPA 70.2 Units of Measurement2.1 In addition to being stated in the inch/pound units that are customary in the USA, each of therequirements in this outline is also stated in units that make the requirement conveniently usable incountries employing the
9、 metric system (practical SI). Equivalent although not necessarily exactlyidentical results are to be expected from applying a requirement in USA or metric terms. Equipmentcalibrated in metric units is to be used when a requirement is applied in metric terms.3 Components3.1 Except as indicated in 3.
10、2, a component (including gaskets and polymeric materials) of a productcovered by this outline of investigation shall comply with the requirements for that component.3.2 A component is not required to comply with a specific requirement that:a) Involves a feature or characteristic not required in the
11、 application of the component in theproduct covered by this outline of investigation, orb) Is superseded by a requirement in this outline of investigation.3.3 A component shall be used in accordance with its rating established for the intended conditions ofuse.3.4 Specific components are incomplete
12、in construction features or restricted in performance capabilities.Such components are intended for use only under limited conditions, such as certain temperatures notexceeding specified limits, and shall be used only under those specific conditions.DECEMBER 5, 2007SUBJECT 25714UL COPYRIGHTED MATERI
13、AL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM UL4 Undated References4.1 Any undated reference to a code or standard appearing in the requirements of this outline ofinvestigation shall be interpreted as referring to the latest edition of that code or standard.CONST
14、RUCTION5 Materials and Workmanship5.1 Only materials that are acceptable for the particular use shall be employed in a wire. Wires shall bemade and finished with the degree of uniformity and grade of workmanship that are practicable in awell-equipped factory.5.2 Each material used in a wire shall be
15、 compatible with all of the other materials used in the wire.6 Conductors6.1 Conductors shall be 18 AWG 250 kcmil, annealed solid or stranded copper, bare or coated.6.2 Insulated conductors shall be single conductor Types THW-2, THWN-2, UF, USE, XHHW-2, RHW-2,THHW, THW, THWN, RHW, XHHW; or Types TFN
16、, TFFN, RFH-2, or FFH-2 using an insulatingcompound rated for at least 60C (140F) wet and dry and comply with the Standard forThermoset-Insulated Wires and Cables, UL 44, the Standard for Fixture Wire, UL 66, the Standard forThermoplastic-Insulated Wires and Cables, UL 83, the Standard for Thermopla
17、stic-Insulated UndergroundFeeder and Branch-Circuit Cables, UL 493, or the Standard for Service-Entrance Cables, UL 854, asappropriate.6.3 Insulated conductors other than those described in 6.1 and 6.2 shall have materials in thicknessesand with temperature ratings appropriate for the specific const
18、ruction of the irrigation cable in which theyare to be used. The materials shall be evaluated for the requested temperature rating as described inLong-Term Aging in the Reference Standard for Electrical Wires, Cables, and Flexible Cords, UL 1581.Investigation of the electrical, mechanical, and physi
19、cal characteristics of these insulated conductors shallshow these conductors to be comparable to the conductors described in 6.1 and 6.2. The investigationshall include tests such as crushing, impact, abrasion, deformation, heat shock, insulation resistance, anddielectric voltage-withstand.DECEMBER
20、5, 2007 SUBJECT 2571 5UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM UL7 Conductor Assembly7.1 These cables consist of one or more insulated conductors. Conductors of different sizes may be usedin the same cable. The insulated conductors shall
21、be cabled. The length of lay is not specified. The cablesshall be provided with fillers where needed to make the finished cable round.7.2 The assembly may be enclosed in a nonmetallic braid, tape, or wrap.7.3 The assembly may be enclosed in a metallic braid, tape, or wrap. A drain wire is not requir
22、ed but maybe provided as a means of facilitating the termination of the shield.8 Inner Jacket (Optional)8.1 An inner jacket employing a flame-retardant thermoplastic or thermosetting compound and of athickness specified in Table 8.1, may be provided.Table 8.1Minimum thicknesses of inner jacketCalcul
23、ated diameter of assemblyunder inner jacketMinimum average thickness of jacket Minimum thickness at any pointInches mm Mils mm Mils mmNot over 0.700 Not over 17.8 30 0.76 24 0.61Over 0.700 but notover 1.500Over 17.8 butnot over 38.145 1.14 36 0.91Over 1.500 but notover 2.500Over 38.1 butnot over 63.
24、560 1.52 48 1.22Over 2.500 Over 63.5 80 2.03 64 1.639 Outer Jacket9.1 An outer jacket employing a thermoplastic or thermosetting compound, and of the thicknessesspecified in Table 9.1, shall be provided.Table 9.1Minimum thicknesses of outer jacketCalculated diameter of assembly underouter jacketMini
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ULSUBJECT25712007OUTLINEOFINVESTIGATIONFORIRRIGATIONFEEDERCONTROLANDSIGNALCABLESISSUE1 灌溉 机械 供电 控制 信号

链接地址:http://www.mydoc123.com/p-1069309.html