UL SUBJECT 2237-2015 UL Outline for Investigation MULTI-POINT INTERCONNECTION POWER CABLE ASSEMBLIES FOR INDUSTRIAL MACHINERY (Issue 4)《用于工业机械的多点互联电力电缆组件的UL调查大纲 (议题4)》.pdf
《UL SUBJECT 2237-2015 UL Outline for Investigation MULTI-POINT INTERCONNECTION POWER CABLE ASSEMBLIES FOR INDUSTRIAL MACHINERY (Issue 4)《用于工业机械的多点互联电力电缆组件的UL调查大纲 (议题4)》.pdf》由会员分享,可在线阅读,更多相关《UL SUBJECT 2237-2015 UL Outline for Investigation MULTI-POINT INTERCONNECTION POWER CABLE ASSEMBLIES FOR INDUSTRIAL MACHINERY (Issue 4)《用于工业机械的多点互联电力电缆组件的UL调查大纲 (议题4)》.pdf(66页珍藏版)》请在麦多课文档分享上搜索。
1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULAPRIL 20, 20151UL 2237Outline of Investigation for Multi-Point Interconnection Power CableAssemblies For Industrial MachineryIssue Number: 4April 20, 2015Summary of TopicsThis Fourth Issue of the
2、 Outline of Investigation for Multi-PointInterconnection Power Cable Assemblies for Industrial Machinery, UL2237, has been published and now covers power cable assemblies thatare rated 1000 V or less, when intended to be used on industrialmachinery in accordance with the National Fire Protection Ass
3、ociationElectrical Standard for Industrial Machinery, NFPA 79 that have systemvoltages up to and including 1000 V. Other editorial revisions have beenmade throughout to reflect present practice.ULs Outlines of Investigation are copyrighted by UL. Neither a printed norelectronic copy of an Outline of
4、 Investigation should be altered in any way. All ofULs Outlines of Investigation and all copyrights, ownerships, and rights regardingthose Outlines of Investigation shall remain the sole and exclusive property of UL.COPYRIGHT 2015 UNDERWRITERS LABORATORIES INC.UL COPYRIGHTED MATERIAL NOT AUTHORIZED
5、FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULAPRIL 20, 2015UL 22372No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULCONTENTSINTRODUCTION1 Scope .52 Glossary .63 Components 74 Units of Measurement .85 Ref
6、erences .8CONSTRUCTION6 Accessibility of Uninsulated Live Parts 87 Insulating Materials 107.1 Insulating materials for devices rated 600 V or less 107.2 Insulating materials for devices rated 601 1000 V .148 Live Parts 159 Grounding and Dead-Metal Parts 1510 Terminals 1611 Strain Relief and Cord Ent
7、ries 1712 Spacings 1712.1 Spacing for devices rated 600 V or less .1712.2 Spacings for devices rated 601 1000 V .1812.3 Alternate spacings clearance and creepage distances 1813 Assembly 1913.1 General .1913.2 Polarization 2013.3 Mating and interchangeability 2013.4 Terminal identification .2014 Encl
8、osure 2215 Flexible Cord, Cable or Wiring 2216 Mounting 2217 Environmental Rating .2217.1 Jacket adhesion 2218 Outdoor Use .23PERFORMANCE19 General .2320 Mold Stress-Relief Distortion Test .2421 Moisture Absorption Test 2522 Dielectric Voltage-Withstand Test 2623 Insulation Resistance Test .2724 Con
9、ductor Secureness Test 2725 Strain-Relief Test .2825.1 Cord-to-fitting test 2825.2 Feeder-tap cable systems test .2926 Overload Test .3027 Temperature Test 3128 Resistance to Arcing Test 3229 Current-Cycling and Vibration Test .3229.1 General .32APRIL 20, 2015 UL 2237 3UL COPYRIGHTED MATERIAL NOT AU
10、THORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM UL29.2 Current-cycling before vibration test 3329.3 Vibration test 3329.4 Current-cycling after vibration test 3329.5 Calculations .3430 Jacket Retention Test 3431 Polarization Test .3432 Adhesion Test .3533 Environmental Enclo
11、sure Tests .3534 Grounding (Bonding) Path Current Test .3535 Cable Pullout Test (For Pin Type or Insulation Displacement Type Terminals) .3536 Creep Test (For Pin Type or Insulation Displacement Type Terminals) 3637 Short-Circuit Withstand Test .3637.1 General .3637.2 Protective devices 3837.3 Calib
12、ration of test circuits 4237.4 Alternating-current circuits .4237.5 Available current of 10,000 A or less .4337.6 Available current more than 10,000 A .4437.7 Instrumentations for test currents above 10,000 A 4637.8 Direct current circuits .4737.9 Calibration characteristics for protective device 49
13、38 Humidity Conditioning Test .5139 Crush Test .5140 No-Load Endurance Test 5241 Impact Test (Male and Female Fittings) .5242 Abnormal Overload Test .5443 Resistance to Corrosion Test .5544 Accelerating Aging Tests 5644.1 General .5644.2 Rubber, EPDM, and TEE compounds .5644.3 PVC compounds and copo
14、lymers 5645 Insulating Materials .5745.1 Glow wire test .5745.2 Comparative tracking index test 5745.3 High-current arc resistance to ignition test .57MANUFACTURING AND PRODUCTION TESTS46 Dielectric Voltage-Withstand Test .58RATINGS47 General 60MARKINGS48 Details 6049 Environmental Enclosures .62App
15、endix AStandards for ComponentsA1APRIL 20, 2015UL 22374UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULINTRODUCTION1 Scope1.1 This outline of investigation covers multi-point interconnection power cable assemblies. They mayconsist of power cab
16、le assemblies, male and female power cable fittings, panel-mounted powercable/conductor fittings and feeder-tap power cable fittings used with industrial machinery in accordancewith the National Fire Protection Association Electrical Standard for Industrial Machinery, NFPA 79 thathave system voltage
17、s up to and including 1000 V.1.2 These interconnection power cable assemblies may be used in an industrial environment to distributethe power to branch circuits, including motor branch circuits, of industrial machinery.1.3 Devices covered under this outline of investigation are only intended for ind
18、oor use, unless otherwiseidentified.1.4 The power cable assemblies covered under this outline of investigation are rated 1000 V or less, andare intended to be used on industrial machinery in accordance with the National Fire ProtectionAssociation Electrical Standard for Industrial Machinery, NFPA 79
19、 that have system voltages up to andincluding 600 V. Each power cable assemblies and fittings are rated in volts and amperes. The electricalratings are marked, on each device or on a flag label affixed to each individual power cable assembly.1.5 The cable assembly fittings and panel-mount fittings a
20、re intended to be installed in accordance withthe manufacturers installation instructions. The cable assembly fittings are intended to be assembled ormolded on flexible cord. The power cable assemblies and mating fittings are not intended to be used asa substitute for the fixed wiring of the buildin
21、g structure. The power cable assemblies and mating fittingsmay be connected to the fixed wiring of the building structure; using a feeder tap fitting or male/femalecable fitting.1.6 Power cable assemblies and fittings covered under this outline of investigation are not intended tomake or interrupt c
22、urrent under load conditions. These power cable assemblies and fittings have beeninvestigated to their marked short-circuit current rating. Power cable assemblies and fittings may specifya maximum ampere rating, type of overcurrent protective device, or both. Unless otherwise marked, thepower cable
23、assemblies and fittings are intended to be supplied from an overcurrent protective device ofthe maximum ampere rating permitted by the Relationship Between Conductor Size and Maximum Ratingor Setting of Short-Circuit Protective Device for Power Circuits Table, Table 7.2.10.4, of the National FirePro
24、tection Association Electrical Standard for Industrial Machinery, NFPA 79.1.7 This outline of investigation does not cover male-to-male cable assemblies or multi-outlet fittings.1.8 These devices are intended for use only with the manufacturers same line of products covered underthis outline of inve
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ULSUBJECT22372015ULOUTLINEFORINVESTIGATIONMULTIPOINTINTERCONNECTIONPOWERCABLEASSEMBLIESFORINDUSTRIALMACHINERYISSUE4

链接地址:http://www.mydoc123.com/p-1069246.html