UL SUBJECT 2187-2006 OUTLINE OF INVESTIGATION FOR DEODORIZERS OZONE GENERATOR TYPE (Issue 2)《臭氧发生器型除臭剂调查大纲 发布编号 2》.pdf
《UL SUBJECT 2187-2006 OUTLINE OF INVESTIGATION FOR DEODORIZERS OZONE GENERATOR TYPE (Issue 2)《臭氧发生器型除臭剂调查大纲 发布编号 2》.pdf》由会员分享,可在线阅读,更多相关《UL SUBJECT 2187-2006 OUTLINE OF INVESTIGATION FOR DEODORIZERS OZONE GENERATOR TYPE (Issue 2)《臭氧发生器型除臭剂调查大纲 发布编号 2》.pdf(10页珍藏版)》请在麦多课文档分享上搜索。
1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULDecember 21, 20061SUBJECT 2187OUTLINE OF INVESTIGATIONFORDEODORIZERS, OZONE GENERATOR TYPEIssue Number: 2DECEMBER 21, 2006Summary of TopicsThis new issue of SU 2187 is being issued through ULs el
2、ectronicpublishing system to ensure format uniformity between the PDF andHTML versions of the document. No substantive changes have beenincorporated in the document.The UL Foreword is no longer located within the UL Standard. For informationconcerning the use and application of the requirements cont
3、ained in thisStandard, the current version of the UL Foreword is located onULStandardsInfoNet at: http:/ 2006 UNDERWRITERS LABORATORIES INC.UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULDECEMBER 21, 2006SUBJECT 21872No Text on This PageUL CO
4、PYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULCONTENTSINTRODUCTION1 Scope .42 General 42.1 Units of measurement .42.2 Terminology .42.3 Undated references .5CONSTRUCTION3 Timers .5PERFORMANCE4 Ozone Test 5MARKINGS AND INSTALLATION INSTRUCTIONS5 I
5、nformational Markings .66 Cautionary Markings 77 Installation and Operating Instructions .7DECEMBER 21, 2006 SUBJECT 2187 3UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULINTRODUCTION1 Scope1.1 These requirements apply to commercial deodorizin
6、g equipment intended to remove odors by the useof ozone generation in hotel rooms while the area is unoccupied.1.2 The equipment is intended for operation in accordance with the manufacturers instructions by trainedservice personnel only.1.3 The equipment shall comply with the applicable requirement
7、s in the Standard for Electrostatic AirCleaners, UL 867, in addition to the requirements contained in this outline.1.4 A product that contains features, characteristics, components, materials, or systems new or differentfrom those covered by the requirements in this outline, and that involves a risk
8、 of fire, electric shock, orinjury to persons shall be evaluated using the appropriate additional component and end-productrequirements as determined necessary to maintain the acceptable level of safety as originally anticipatedby the intent of this outline. A product whose features, characteristics
9、, components, materials, or systemsconflict with specific provisions of this outline cannot be judged to comply with this outline. Whereconsidered appropriate, revision of requirements shall be proposed and adopted in conformance with themethods employed for development, revision, and implementation
10、 of this outline.2 General2.1 Units of measurement2.1.1 If a value for measurement is followed by a value in other units in parentheses, the second valuemay be only approximate. The first stated value is the requirement.2.2 Terminology2.2.1 The terms equipment, unit, and device as used in these requ
11、irements refer to all ozone,generator type, commercial deodorizers or any part thereof covered by these requirements unlessspecifically noted otherwise.DECEMBER 21, 2006SUBJECT 21874UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM UL2.3 Undated r
12、eferences2.3.1 Any undated reference to a code or standard appearing in the requirements of this outline shall beinterpreted as referring to the latest edition of that code or standard.CONSTRUCTION3 Timers3.1 A timer shall be employed in the equipment and shall have a maximum on time of 60 minutes,
13、andshall not be overridden by a manual switch or the like.3.2 Upon completion of the timer on period, the equipment shall be rendered inoperable until the timeris manually reset.PERFORMANCE4 Ozone Test4.1 A portable unit for commercial use in unoccupied areas shall not produce a concentration of ozo
14、neexceeding 0.8 parts per million by volume during a maximum 60 minute operation period. During theozone decay period immediately following the unit operation period, while the unit is de-energized, theozone decay level shall not exceed 0.3 parts per million by volume after 30 minutes and shall not
15、exceeda time-weighted average of 0.1 parts per million over the next 8 hours, and shall not exceed 0.05 partsper million by volume thereafter when tested as described in 4.2 4.9.4.2 The test is to be conducted in a room having a volume of 3600 4250 cubic feet (97.3 115.0 m3)with a minimum side dimen
16、sion of 15 feet (4.5 m) and a maximum height dimension of 10 feet (30 m)without openings. The test room conditions are to be representative of a typical use hotel room (roomsize, carpeted floor, wall papered walls, bedding, curtains, fabric covered chair, bathroom, towels, closet).4.3 During the tes
17、t, the test room is to be maintained at a temperature of 77 4F (25 2C) and a relativehumidity of 50 5 percent. Prior to the start of this test, the ozone background level is to be measuredwith the unit off. The background level average shall be calculated and subtracted from the maximumozone measure
18、ment during the test.4.4 The unit is to be located in the test room as recommended by the manufacturers instructions.4.5 The ozone monitor sampling tube is to be located 2 inches (50 mm) from the air outlet of the unit andis to point directly into the air stream.4.6 Ozone concentrations are to be mo
19、nitored for 24 hours and recorded. The monitoring time may bereduced if stabilization or ultimate conditions occur prior to 24 hours.4.7 The smoke generated from four (4) smoked cigarettes shall be introduced into the room prior to thetest.DECEMBER 21, 2006 SUBJECT 2187 5UL COPYRIGHTED MATERIAL NOT
20、AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM UL4.8 The ventilation system to the room is to be closed off to prevent external air exchanges. The entrydoor of the room is to be sealed with tape during the test.4.9 If the device can be energized with any of its fans not f
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ULSUBJECT21872006OUTLINEOFINVESTIGATIONFORDEODORIZERSOZONEGENERATORTYPEISSUE2 臭氧发生器 除臭剂 调查 大纲 发布 编号 PDF

链接地址:http://www.mydoc123.com/p-1069242.html