UL 921 CRD-2017 UL Standard for Safety Commercial Dishwashers - Section Paragraph Reference Supplement SA Subject Commercial Dishwashers provided with a Heat Pump (Edition 7 March .pdf
《UL 921 CRD-2017 UL Standard for Safety Commercial Dishwashers - Section Paragraph Reference Supplement SA Subject Commercial Dishwashers provided with a Heat Pump (Edition 7 March .pdf》由会员分享,可在线阅读,更多相关《UL 921 CRD-2017 UL Standard for Safety Commercial Dishwashers - Section Paragraph Reference Supplement SA Subject Commercial Dishwashers provided with a Heat Pump (Edition 7 March .pdf(2页珍藏版)》请在麦多课文档分享上搜索。
1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULUNDERWRITERS LABORATORIES INC. CERTIFICATION REQUIREMENT DECISIONThis Certification Requirement Decision is prepared by UL LLC. It is normative for the applicable ULProduct Certification Program(
2、s); however, it is currently not part of the UL Standard(s) referencedbelow.Product Category (CCN): DMGR/DMGR7Standard Number: UL 921Standard Title: Standard for Commercial DishwashersEdition Date: March 23, 2016Edition Number: 7Section / Paragraph Reference: Supplement SASubject: Commercial Dishwas
3、hers provided with a Heat PumpDECISION:SUPPLEMENT SA - COMMERCIAL DISHWASHERS SELF-CONTAINED CONDENSING SYSTEMSINTRODUCTIONSA1 ScopeSA1.1 These requirements cover commercial, freestanding dishwashers which incorporate aself-contained condensing system to capture heat and water vapors, thereby reduci
4、ng the residual heatgain to the premises. These dishwashers are sometimes referred to as “ventless dishwashers”. Theserequirements also cover dishwashers provided with a heat pump. These requirements add to theapplicable requirements in the body of this Standard.SA3A Commercial Dishwashers provided
5、with a heat pumpSA3A.1 A dishwasher provided with a heat pump shall comply with the applicable requirements of CSAC22.2 No. 236 and UL 1995, utilizing the additional guidance as specified below:a) The testing shall be conducted as specified in Table SA3;b) Flammable refrigerants shall not be employe
6、d for commercial dishwashers;c) Refrigerant motor compressors shall comply with:1) CSA C22.2 No. 140.2 or CAN/CSA-C22.2 No. 60335-2-34; and2) UL 984 or UL 60335-2-34.d) Refrigerant containing parts shall comply with Clause 34 of UL 1995/CSA C22.2 No. 236;e) Refrigerant marking and amount shall compl
7、y with Clause 44.3(j) of UL 1995/CSA C22.2 No.236; andf) The Manufacturing and Production tests pressure tests for leakage and strength, shall beconducted in accordance with Clause 85 of UL 1995/CSA C22.2 No.236.UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT P
8、ERMISSION FROM ULTable SA3 - Test conditions for heat pump commercial dishwasher(See Clause SA3)CSA C22.2 No. 236 / UL 1995 Test Test ConditionsInput Test Conducted in conjunction with UL921/CSA C22.2 No. 168,Clause 7.21Starting Test Conducted in conjunction with UL921/CSA C22.2 No. 168,Clause 7.31H
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- UL921CRD2017ULSTANDARDFORSAFETYCOMMERCIALDISHWASHERSSECTIONPARAGRAPHREFERENCESUPPLEMENTSASUBJECTCOMMERCIALDISHWASHERSPROVIDEDWITHAHEATPUMPEDITION7MARCHPDF

链接地址:http://www.mydoc123.com/p-1069056.html