UL 634 CRD-2013 UL Standard for Safety Connectors and Switches for Use with Burglar-Alarm Systems - Section Paragraph Reference Sections 19 2 and 64 Subject Operating Gap C All Swi.pdf
《UL 634 CRD-2013 UL Standard for Safety Connectors and Switches for Use with Burglar-Alarm Systems - Section Paragraph Reference Sections 19 2 and 64 Subject Operating Gap C All Swi.pdf》由会员分享,可在线阅读,更多相关《UL 634 CRD-2013 UL Standard for Safety Connectors and Switches for Use with Burglar-Alarm Systems - Section Paragraph Reference Sections 19 2 and 64 Subject Operating Gap C All Swi.pdf(2页珍藏版)》请在麦多课文档分享上搜索。
1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULUNDERWRITERS LABORATORIES INC. CERTIFICATION REQUIREMENT DECISIONThis Certification Requirement Decision is prepared and published by Underwriters Laboratories Inc.(UL). It is normative for the a
2、pplicable UL Product Certification Program(s); however, it is currently notpart of the UL Standard(s) referenced below.Product Category (CCN): AMQV, AMQV2Standard Number: UL 634Standard Title: Standard for Connectors and Switches for Use with Burglar-AlarmEdition Date: October 12, 2007Edition Number
3、: 9Section / Paragraph Reference: Sections 19.2 and 64Subject: Operating Gap All SwitchesDECISION:All UL 634 switches must meet the minimum operating gap of 1/8 inch (3.2 mm) specified in section 19in addition to the specific requirements of sections 49 65 for Level 1 and Level 2 switches. Clarifyin
4、gstatements are shown in strike through and underlined text.19 Operation Test19.1 General19.2 Magnetically actuated switches19.2.1 Magnetically actuated switches intended for installation on magnetic materials shall operate asintended with a gap of 1/8 inch (3.2 mm) or more between the magnet and th
5、e switch housings when bothhousings are mounted on a 1/4 inch (6.4 mm) thick mild steel plate as intended in service.19.2.1.1 Level 1 and Level 2 high security switches shall have an operational gap of 1/8 in. (3.2 mm) inaddition to complying with the applicable requirements specified in Sections 49
6、 65.19.2.2 As the maximum acceptable gap of separation is based upon the parameters of field installation,the gap of separation of unmounted samples of each magnetically actuated switch construction is to bemeasured on nonmagnetic material for informational purposes. The gap of separation is the dis
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- UL634CRD2013ULSTANDARDFORSAFETYCONNECTORSANDSWITCHESFORUSEWITHBURGLARALARMSYSTEMSSECTIONPARAGRAPHREFERENCESECTIONS192AND64SUBJECTOPERATINGGAPCALLSWIPDF

链接地址:http://www.mydoc123.com/p-1068779.html