UL 60730-2-2 (ND)-2004 National Differences For UL 60730-2-2 Standard for Automatic Electrical Controls for Household and Similar Use Part 2 Particular Requirements for Thermal Motv.pdf
《UL 60730-2-2 (ND)-2004 National Differences For UL 60730-2-2 Standard for Automatic Electrical Controls for Household and Similar Use Part 2 Particular Requirements for Thermal Motv.pdf》由会员分享,可在线阅读,更多相关《UL 60730-2-2 (ND)-2004 National Differences For UL 60730-2-2 Standard for Automatic Electrical Controls for Household and Similar Use Part 2 Particular Requirements for Thermal Motv.pdf(12页珍藏版)》请在麦多课文档分享上搜索。
1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULNational Differences ForUL 60730-2-2Standard for Automatic Electrical Controls for Household and Similar Use; Part 2: ParticularRequirements for Thermal Motor ProtectorsUL COPYRIGHTED MATERIAL NO
2、T AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULNational Differences ForUL 60730-2-2Standard for Automatic Electrical Controls for Household and Similar Use; Part 2: ParticularRequirements for Thermal Motor ProtectorsEdition: 2Edition Date: May 19, 2004These revisions
3、to UL 60730-2-2 are being issued to revise the endurance test and addrequirements covering deviation and drift to provide a performance/reliability bench mark forthermal motor protectors when tested to the manufacturers declared electrical and thermalrating.This document provides a single listing of
4、 the National Differences included in the UL adoption ofthe corresponding IEC standard.All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, ortransmitted in any form by any means, electronic, mechanical photocopying, recording, or otherwisewithout prior p
5、ermission of UL.UL provides this standards document as is without warranty of any kind, either expressed or implied,including but not limited to, the implied warranties of merchantability or fitness for any purpose.In no event will UL be liable for any special, incidental, consequential, indirect or
6、 similar damages,including loss of profits, lost savings, loss of data, or any other damages arising out of the use of or theinability to use this standards document, even if UL or an authorized UL representative has been advisedof the possibility of such damage. In no event shall ULs liability for
7、any damage ever exceed the pricepaid for this standards document, regardless of the form of the claim.Users of the electronic versions of ULs Standards for Safety agree to defend, indemnify, and hold ULharmless from and against any loss, expense, liability, damage, claim, or judgment (including reas
8、onableattorneys fees) resulting from any error or deviation introduced while purchaser is storing an electronicStandard on the purchasers computer system.Copyright 2014 Underwriters Laboratories Inc.MARCH 7, 2014NATIONAL DIFFERENCES FOR UL UL 60730-2-22UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURT
9、HER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULPrefaceThis document provides a single listing of the technical National Differences included in the UL adoptionof the corresponding IEC standard.In its IEC-based standards, UL uses the notations indicated below to identify national differenc
10、e type, andthese types are additionally noted in this document. The standard may not use all types of thesedeviations.D1 - These are deviations which are based on basic safety principles and requirements, elimination ofwhich would compromise safety for U.S. consumers and users of products.D2 - These
11、 are deviations based on safety practices. These are deviations for IEC requirements that maybe acceptable, but adopting the IEC requirements would require considerable retesting or redesign on themanufacturers part.DC - These are deviations based on the component standards and will not be deleted u
12、ntil a particularcomponent standard is harmonized with the IEC component standard.DE - These are deviations based on editorial comments or corrections.DR - These are deviations based on the national regulatory requirements.Each national difference contains a description of what the national differen
13、ce entails. Typically one of thefollowing words is used to explain how the text of the national difference is to be applied to the base IECtext:Addition / Add - An addition entails adding a complete new numbered clause, subclause, table,figure, or annex. Addition is not meant to include adding selec
14、t words to the base IEC text.Deletion / Delete - A deletion entails complete deletion of an entire numbered clause, subclause,table, figure, or annex without any replacement text.Modification / Modify - A modification is an altering of the existing base IEC text such as theaddition, replacement or d
15、eletion of certain words or the replacement of an entire clause,subclause, table, figure, or annex of the base IEC text.MARCH 7, 2014 NATIONAL DIFFERENCES FOR UL UL 60730-2-2 3UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULNational Difference
16、s1.1DV DE Modification of 1.1 to by adding the following note after the third paragraph:Thermal motor protectors that are off-winding (not integrated with the motor winding) to the motor are coveredunder the scope of this part 2 and may be considered incorporated controls with respective to the requ
17、irementsof this standard.1.1DV.2 Deleted March 7, 2014.1.1.101DV D2 Addition:1.1.101DV.1 In the U.S.A, this standard applies to thermal motor protectors designed forhousehold, commercial, or industrial use.1.1.102DV D2 Addition:1.1.102DV.1 This standard does not apply to a motor protector the contac
18、ts of whichcontrol a relay coil in a motor starter.1.1.102DV.2 A thermal cutoff shall comply with the requirements in the Standard forThermal-Links Requirements and Application Guide, UL 60691, in addition to therequirements of this standard.2.6.101DV D2 Modification by adding the following notes:NO
19、TE 1 Type 3 action applies to in-winding, integrated thermal motor protectors.NOTE 2 Type 2 action applies to off-winding, incorporated thermal motor protectors.4.3.2DV D2 Modification of 4.3.2:4.3.2DV.1 The requirements in 4.3.2 are applicable.5DV D2 Modification of clause 5:5DV.1 This clause of th
20、e Part 1 is applicable.6.4.2DV D2 Replacement of 6.4.2 with the following:6.4.2DV.1 This clause of the Part 1 is applicable to thermal motor protectors declared tobe incorporated with deviation, drift and endurance values in Table 7.2.6.4.2.101DV D2 Addition: Type 3 action.MARCH 7, 2014NATIONAL DIFF
21、ERENCES FOR UL UL 60730-2-24UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM UL6.4.3.3DV D2 Modification to 6.4.3.3:6.4.3.3DV.1 Void.6.11DV D2 Modification of 6.11 by replacing it with the following:6.11DV.1 This clause of the Part 1 is applicabl
22、e for controls declared to be incorporatedwith endurance values in Table 7.2.Table 7DV D2 Modification of Table 7.2 with the following eight national differences:DV.1 Insert row 7, with the first column being “7”, the second column being “The type ofload controlled7)”, the third column being “17, 6.
23、2”, and the fourth column being “X”.DV.2 Insert row 27, with the first column being “27”, the second column being “Number ofautomatic cycles (A) for each AUTOMATIC ACTION)”, the third column being “6.11DV.1,17.8”, and the fourth column being “X”.”.DV.3 Insert row 37, with the first column being “37”
24、, the second column being “Minimumand/or maximum rates of change of ACTIVATING QUANTITY, or minimum and/or maximumcycling rates for a SENSING CONTROL4)”, the third column being “15, 17”, and the fourthcolumn being “X”.DV.4 Insert row 39, with the first column being “39”, the second column being “Typ
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- UL6073022ND2004NATIONALDIFFERENCESFORUL6073022STANDARDFORAUTOMATICELECTRICALCONTROLSFORHOUSEHOLDANDSIMILARUSEPART2PARTICULARREQUIREMENTSFORTHERMALMOTVPDF

链接地址:http://www.mydoc123.com/p-1068484.html