UL 1082 CRD-2014 UL Standard for Safety Household Electric Coffee Makers and Brewing-Type Appliances - Section Paragraph Reference New Supplement SC Subject Smart Enabled Electricd.pdf
《UL 1082 CRD-2014 UL Standard for Safety Household Electric Coffee Makers and Brewing-Type Appliances - Section Paragraph Reference New Supplement SC Subject Smart Enabled Electricd.pdf》由会员分享,可在线阅读,更多相关《UL 1082 CRD-2014 UL Standard for Safety Household Electric Coffee Makers and Brewing-Type Appliances - Section Paragraph Reference New Supplement SC Subject Smart Enabled Electricd.pdf(8页珍藏版)》请在麦多课文档分享上搜索。
1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULUNDERWRITERS LABORATORIES INC. CERTIFICATION REQUIREMENT DECISIONThis Certification Requirement Decision is prepared and published by Underwriters Laboratories Inc.(UL). It is normative for the a
2、pplicable UL Product Certification Program(s); however, it is currently notpart of the UL Standard(s) referenced below.Product Category (CCN): KNURStandard Number: UL 1082Standard Title: Standard for Household Electric Coffee Makers and Brewing-TypeAppliancesEdition Date: March 17, 2009Edition Numbe
3、r: 6Section / Paragraph Reference: New Supplement SCSubject: Smart Enabled Electric Coffee Makers and Brewing-Type AppliancesDECISION:(New Supplement)Supplement SC - Safety of Smart Enabled Household Electric Coffee Makers and Brewing-TypeAppliancesSC1 ScopeSC1.1 These requirements apply to househol
4、d electric coffee makers and brewing-type appliancesintended to receive and respond to communication signals or data relating to power billing rate or demandresponse or communication signals from a remote user interface, such as a smart phone or computer.The smart enabled control response may includ
5、e delayed start, remote stop of a function, remote start, orbrew mode.SC1.2 Appliances covered by SC1.1 are commonly identified as smart appliances or smart enabledand are intended to interact with the Smart Grid, as described by the US Energy Independence andSecurity Act of 2007, or other communica
6、tion networks not identified as Smart Grid.SC1.3 These requirements do not address the integrity of any output signal or data to the network devicesor interoperability with other devices.SC1.4 These requirements supplement those specified in this Standard.SC1.5 These requirements contemplate smart e
7、nabled technology as described by the U. S. EnergyIndependence and Security Act of 2007 that is integral with the appliance or incorporated as an accessory(wired to the appliance or wireless with a corresponding appliance receiver) on the appliance or in thesame occupancy as the appliance.SC1.6 Thes
8、e requirements encompass accessory devices to which multiple appliances may communicateand be smart enabled by providing direction for investigation of such devices in addition to therequirements of standards generally applicable to those devices.SC1.7 These requirements do not apply to communicatio
9、n network devices that control appliances viageneral purpose power on-off, building wiring devices, panelboard mounted devices or utility meters.SC1.8 These requirements apply to wired or wireless remote commands from the user by way of:UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION
10、 ORDISTRIBUTION WITHOUT PERMISSION FROM ULa) Controls only capable of communicating within line-of-sight of the appliance (e.g. infraredwireless);b) Short range controls only capable of communicating within proximity or same occupancy ofthe appliance but not necessarily within line-of-sight (e.g. sh
11、ort-wave radio frequency); orc) Long range telecommunication controls without proximity limits (e.g. WiFi, local areanetworks, wide area networks).CONSTRUCTIONSC2 GeneralSC2.1 ControlsSC2.1.1 Controls that respond to external communication signals or data shall comply with theconstruction and perfor
12、mance requirements of the Standard for Automatic Controls for Household andSimilar Use, Part 1: General Requirements, UL 60730-1, and tested as an operating control utilizing theparameters specified in Table SC1. If the control also incorporates protective functions, these controlfunctions shall be
13、evaluated to the requirements for protective controls.Exception No. 1: Not applicable to devices and circuits located in low voltage circuits where the maximumpower available does not exceed 15 W and the device or circuit does not control the load.Exception No. 2: Compliance with the Standard for So
14、lid-State Controls for Appliances, UL 244A, takinginto account criteria comparable to that specified in Table SC1 is considered to fulfill this requirement,except Endurance for automatic, self-resetting, operating Type 2, controls shall be conducted on 100,000cycles.Table SC1Operating Control Parame
15、tersInformation Operating Control RequirementOperating Ambient for control device/circuit As specified by the device manufacturer and verified duringthe Temperature Test, Section 41, of the applianceEndurance Testing for power switching devices A) 100,000 cycles for automatic, self-resetting operati
16、ng Type2 controls and 6,000 cycles for automatic, self-resettingoperating Type 1 controlsB) 6,000 cycles for manual, non-self-resetting operatingcontrolsOvervoltage Category Overvoltage Category IIPollution Degree See Note 1)Note 1) - The internal microenvironment of the enclosure shall be considere
17、d Pollution Degree 2 (that is, an environment thatnormally has only nonconductive pollution, or a temporary conductivity resulting from condensation) as specified in the Standardfor the Standard for Insulation Coordination Including Clearances and Creepage Distances for Electrical Equipment, UL 840.
18、Pollution Degree 1 is permitted at a creepage distance by encapsulation or hermetic sealing. For printed wiring boards, coatingsmay be used that satisfy the performance criteria specified in UL 840.SC2.1.4 With respect to SC2.1.1, a communication device that is not integral with the appliance contro
19、l(e.g. on a separate printed wiring board) and complying with the Standard for Information TechnologyEquipment Safety - Part 1: General Requirements, UL 60950-1 is considered to fulfill this requirement.STANDARD NUMBER: UL 1082 -2-UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDIS
20、TRIBUTION WITHOUT PERMISSION FROM ULSC2.1.5 For the purposes of application of the Standard for Automatic Controls for Household and SimilarUse, Part 1: General Requirements, UL 60730-1, Electromagnetic compatibility (EMC) emissions testingof H23 is not applicable to controls, which are integral wit
21、h the appliance or incorporated as an accessory(wired or wireless) on the appliance or in the same occupancy as the appliance.SC2.1.6 With respect to the Endurance Testing indicated in Table SC1, the control shall remainoperational and comply with the Electric Strength Test of the Standard for Autom
22、atic Controls forHousehold and Similar Use, Part 1: General Requirements, UL 60730-1 (Clause 13.2).SC2.1.7 When the control enclosure forms part of the overall appliance enclosure, the enclosure materialshall have a flammability rating in accordance with Frames and Enclosures, Section 7.SC2.2 Separa
23、tion of CircuitsSC2.2.1 The separation of communication circuits from power and control circuits shall be evaluated forrisk of electric shock in accordance with 14.SC2.2.2 With respect to SC2.2.1, separation of circuit requirements of the following standards areconsidered to fulfill this requirement
24、 the Standard for:a) Automatic Controls for Household and Similar Use, Part 1: General Requirements, UL60730-1; orb) Information Technology Equipment - Safety - Part 1: General Requirements, UL 60950-1.SC2.3 Communication and Display DevicesSC2.3.1 A communication or display device, such as a router
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- UL1082CRD2014ULSTANDARDFORSAFETYHOUSEHOLDELECTRICCOFFEEMAKERSANDBREWINGTYPEAPPLIANCESSECTIONPARAGRAPHREFERENCENEWSUPPLEMENTSCSUBJECTSMARTENABLEDELECTRICDPDF

链接地址:http://www.mydoc123.com/p-1067313.html