SANS 10120-3 HA-1990 Code of practice for use with standardized specifications for civil engineering construction and contract documents Part 3 Guidance for design Section HA Struc.pdf
《SANS 10120-3 HA-1990 Code of practice for use with standardized specifications for civil engineering construction and contract documents Part 3 Guidance for design Section HA Struc.pdf》由会员分享,可在线阅读,更多相关《SANS 10120-3 HA-1990 Code of practice for use with standardized specifications for civil engineering construction and contract documents Part 3 Guidance for design Section HA Struc.pdf(7页珍藏版)》请在麦多课文档分享上搜索。
1、 Collection of SANS standards in electronic format (PDF) 1. Copyright This standard is available to staff members of companies that have subscribed to the complete collection of SANS standards in accordance with a formal copyright agreement. This document may reside on a CENTRAL FILE SERVER or INTRA
2、NET SYSTEM only. Unless specific permission has been granted, this document MAY NOT be sent or given to staff members from other companies or organizations. Doing so would constitute a VIOLATION of SABS copyright rules. 2. Indemnity The South African Bureau of Standards accepts no liability for any
3、damage whatsoever than may result from the use of this material or the information contain therein, irrespective of the cause and quantum thereof. SABS 0120 : Part L Section HA-1990 Structural steelwork (sundry items) PART 3 : GUIDANCE FOR DESIGN SECTION HA CONTENTS Page Number Clause PRE-TENDER CON
4、SIDERATIONS . Investigations Administration . Documentation . General requirements . DESIGN REQUIREMENTS General Minor Structures . Handrailing Systems Selection Tubular handrail stanchions Open Grid Flooring . General Floorplate Flooring Materials Loading Floor strength . Floor stiffeners . Floorpl
5、ate joints Removable floorplates Built-in Items . APPLICABILITY OF OTHER CODES . TEST PROCEDUKES QUALITY CONTROL AND OTHER CONSIDERATIONS . DRAW 1 NGS Drawing HA.3.1 . Typical Handrail Dimensions . First Revision August 1990 Thi s section of tile code supersedes SABS 0120 : Part 3 : Section HA-1984
6、Approved by the COUNCIL OF THE SOUTH AFRICAN BUREAU OF STANDARDS SABS 0120 : Part 3 Section HA-,1990 Strv :tural stee; work (sundry i terns) SABS 1200 HA : STRUCTURAL STEELWORK (SUNDRY ITEMS) NOTE: The clause nurnber(s) given at the beginning or af,Ler the heading of a cl ause islare, unless otherwi
7、se stated, the number(s) of the relevant clause(s) of SABS 1200 HA. PRE-TENDER CONSIDERATIONS INVESTIGATIONS. No specific recommendations. ADMINISTRATION. No specific recommendations. DOCUMENTATION Genra-?e!iremenJs. Except where ructural steelwork constitutes a minor portion f f 3 a conrac.E Wwfiic
8、h SABS 1200 A forms part of the contract document, SABS 1200 AH) in the contract document in preference to either SABS 1200 AIyC:Fde SABS 1200 AA). DESIGN REQUIREMENTS GENERAL. In addition to the recommendations given below, and to those given in Section 12 of the South African Institute of Steel Co
9、nsructions Handbook Metal Flooring, Stairways, Ladders, Platf rms and Handraillng , take into account the recommendations given in Section H47 that have a bearing on the design of the work to be executed in accordance with SABS 1200 HA and apply those details, with the appropriate alteration to the
10、details, to the project in hand. MINOR STRUCTURES (Subclause 3.1). Be conservative in the design of members for structures to be fabricated from commercial quality steel and use a yield stress of not more than 225 MPa . Note particularly the recommendations given in Subclauses 2.2.4 and 3.2.1.2 of S
11、ection H of Part 5 of the code. HANDRAILING SYSTEMS (Subclause 5.2.6) Selection. Except in the case of stainless steel, which may be less than the fa1 loiiTig, the minimum wall thickness of tubular handrails and tubular kneerai l s should be 2,5 mm . Choose a system with slip joints (ferrules) to el
12、iminate site welding. Handrail ing components shall not be welded after having been galvanized. The accepted height from the underside of the stanchion baseplate to the centre of the handrail is 1,O m . A two-rail system is the norm for industrial applications. For domestic use, a balustrade with op
13、ening sizes in accordance with the National Building Regulations is recommended, having due regard for the safety of small children. Stair angles to the horizontal lie between 20“ and 50“. Ramps are less than 20“ and ladders are in excess of 50“. Except for stainless steel or other corrosion-resista
14、nt materials, the minimum wall thickness of tubular stanchions should be 2,5 mm . Ensure that the system offers the hand a free, continuous and smooth passage on the top rail with no obstructions that require the removal of the hand from the handrai l . The handrail system is only as strong as the f
15、oundation to which the stanchion is bolted, e.g. bolting the stanchion to brickwork or inferior concrete or kickplates can be hazardous. In general, handrailing stanchions should not be bolted to kickplates that are welded to flooring. In a highly corrosive environment, select a corrosion-resi stant
16、 material such as stain1 ess steel . Galvanizing usually suffices for outdoors or medium corrosive areas such as coastal areas. The use of tubular stanchions in a corrosive environ- ment can lead to internal corrosion, which cannot easily be detected. Internal corrosion might reach the stage where t
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- SANS101203HA1990CODEOFPRACTICEFORUSEWITHSTANDARDIZEDSPECIFICATIONSFORCIVILENGINEERINGCONSTRUCTIONANDCONTRACTDOCUMENTSPART3GUIDANCEFORDESIGNSECTIONHASTRUCPDF

链接地址:http://www.mydoc123.com/p-1028526.html