SAE J 3074-2017 Lumbar Flexion Test Procedure for the Hybrid III 50th Male Dummy.pdf
《SAE J 3074-2017 Lumbar Flexion Test Procedure for the Hybrid III 50th Male Dummy.pdf》由会员分享,可在线阅读,更多相关《SAE J 3074-2017 Lumbar Flexion Test Procedure for the Hybrid III 50th Male Dummy.pdf(8页珍藏版)》请在麦多课文档分享上搜索。
1、_ SAE Technical Standards Board Rules provide that: “This report is published by SAE to advance the state of technical and engineering sciences. The use of this report is entirely voluntary, and its applicability and suitability for any particular use, including any patent infringement arising there
2、from, is the sole responsibility of the user.” SAE reviews each technical report at least every five years at which time it may be revised, reaffirmed, stabilized, or cancelled. SAE invites your written comments and suggestions. Copyright 2017 SAE International All rights reserved. No part of this p
3、ublication may be reproduced, stored in a retrieval system or transmitted, in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise, without the prior written permission of SAE. TO PLACE A DOCUMENT ORDER: Tel: 877-606-7323 (inside USA and Canada) Tel: +1 724-776-497
4、0 (outside USA) Fax: 724-776-0790 Email: CustomerServicesae.org SAE WEB ADDRESS: http:/www.sae.org SAE values your input. To provide feedback on this Technical Report, please visit http:/standards.sae.org/J3074_201702 SURFACE VEHICLE RECOMMENDED PRACTICE J3074 FEB2017 Issued 2017-02 Lumbar Flexion T
5、est Procedure for the Hybrid III 50thMale Dummy RATIONALE A bend test was designed to provide a force vs. angle requirement to accompany the existing durometer specification of the Hybrid III 50thrubber lumbar. TABLE OF CONTENTS 1. SCOPE 2 1.1 Purpose . 2 2. REFERENCES 2 2.1 Applicable Documents 2 2
6、.1.1 SAE Publications . 2 2.2 Related Publication . 2 2.2.1 Federal Publication . 2 3. CERTIFICATION PROCEDURES 2 3.1 Equipment Required . 2 3.2 Instrumentation Specifications 6 3.3 Test Preparation 7 3.4 Test Procedure 7 3.5 Performance Specifications 8 4. NOTES 8 4.1 Revision Indicator 8 FIGURE 1
7、NECK BRACKET REPLACEMENT 3 FIGURE 2 78051-179 SPINE BOX. 4 FIGURE 3 78051-362 SPINE BOX MOUNTING PLATE . 4 FIGURE 4 ANGLE REFERENCE PLANE 5 FIGURE 5 LUMBAR FLEXION TEST EQUIPMENT 5 FIGURE 6 HOLD POSITION FOR 30 MINUTES . 6 FIGURE 7 PULL DOWN ANGLE 52.5 WHEN SPINE IS 45 . 6 FIGURE 8 LUMBAR FLEXION TE
8、ST DEFINITION . 8 TABLE 1 PERFORMANCE CRITERIA 8 SAE INTERNATIONAL J3074 FEB2017 Page 2 of 8 1. SCOPE This procedure establishes a recommended practice for performing a Lumbar Flexion test to the Hybrid III 50th Male Anthropomorphic Test Device (ATD or crash dummy). This test was created to satisfy
9、the demand from industry to have a certification test which characterizes the lumbar without interaction of other dummy components. In the past, there have not been any tests to evaluate the performance of Hybrid III 50thlumbar. 1.1 Purpose The intent of this recommended practice is to develop a lum
10、bar flexion test procedure for the H-III50M dummy with test corridors for initial angle and force at 22.1, 32.1, and 42.1 angles. The test will utilize standard H-III family torso flexion test equipment. 2. REFERENCES 2.1 Applicable Documents The following publications form a part of this specificat
11、ion to the extent specified herein. Unless otherwise indicated, the latest issue of SAE publications shall apply. 2.1.1 SAE Publications Available from SAE International, 400 Commonwealth Drive, Warrendale, PA 15096-0001, Tel: 877-606-7323 (inside USA and Canada) or +1 724-776-4970 (outside USA), ww
12、w.sae.org. SAE J211/1 Instrumentation for Impact Test - Part 1 - Electronic Instrumentation SAE J2856 Users Manual for the 50th Percentile Male Hybrid III Dummy 2.2 Related Publication The following publication is provided for information purposes only and are not a required part of this SAE Technic
13、al Report. 2.2.1 Federal Publication Copies of these documents are available online at http:/www.ecfr.gov. Motor Vehicle Regulation No. 572 Test Dummies SpecificationsAnthropomorphic Test Dummy for Applicable Test Procedures 3. CERTIFICATION PROCEDURES 3.1 Equipment Required a. Lower Torso Assembly
14、78051-070 (Without abdomen). b. Lumbar Spine 78051-66. c. Neck Bracket Replacement Figure 1 describes the generic shape, mass, and the pull point dimensions. SAE INTERNATIONAL J3074 FEB2017 Page 3 of 8 LUMBAR FLEXION PULL POINT Figure 1 - Neck bracket replacement SAE INTERNATIONAL J3074 FEB2017 Page
15、 4 of 8 d. Spine Box Assembly 78051-179 - Shown in Figure 2 without ballast mass insert. Figure 2 - 78051-179 Spine box e. Spine Box Mounting Plate Adapter 78051-362 - Shown in Figure 3 mounted between spine box and lumbar. Figure 3 - 78051-362 Spine box mounting plate f. Leg Assemblies 86-5001-001
16、(left); 86-5001-002 (right); lower legs and feet may be used, but not required. g. Pelvic Adapter The type of pelvic adapter is not critical, as long as it securely fastens to the pelvic instrumentation cover mounting holes and holds the entire assembly firmly with the back of the instrumentation co
17、ver mounting surface vertical (1) and maintains the pull relationships found in Figure 7. h. Angle Measurement Device To measure the back of the spine box angle at the instrument cavity. The design of this bracket is not critical, as long as it references the back of the instrumentation cavity. This
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- SAEJ30742017LUMBARFLEXIONTESTPROCEDUREFORTHEHYBRIDIII50THMALEDUMMYPDF

链接地址:http://www.mydoc123.com/p-1027802.html