SAE J 3043-2014 Ambulance Equipment Mount Device or Systems《救护仪器安装设备或系统》.pdf
《SAE J 3043-2014 Ambulance Equipment Mount Device or Systems《救护仪器安装设备或系统》.pdf》由会员分享,可在线阅读,更多相关《SAE J 3043-2014 Ambulance Equipment Mount Device or Systems《救护仪器安装设备或系统》.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、_SAE Technical Standards Board Rules provide that: “This report is published by SAE to advance the state of technical and engineering sciences. The use of this report is entirely voluntary, and its applicability and suitability for any particular use, including any patent infringement arising theref
2、rom, is the sole responsibility of the user.”SAE reviews each technical report at least every five years at which time it may be revised, reaffirmed, stabilized, or cancelled. SAE invites your written comments and suggestions.Copyright 2014 SAE InternationalAll rights reserved. No part of this publi
3、cation may be reproduced, stored in a retrieval system or transmitted, in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise, without the prior written permission of SAE.TO PLACE A DOCUMENT ORDER: Tel: 877-606-7323 (inside USA and Canada)Tel: +1 724-776-4970 (out
4、side USA)Fax: 724-776-0790Email: CustomerServicesae.orgSAE WEB ADDRESS: http:/www.sae.orgSAE values your input. To provide feedbackon this Technical Report, please visithttp:/www.sae.org/technical/standards/J3043_201407SURFACE VEHICLERECOMMENDED PRACTICEJ3043 JUL2014Issued 2014-07Ambulance Equipment
5、 Mount Device or SystemsRATIONALEThis SAE Recommended Practice was developed by members of the SAE Truck Crashworthiness Committee in support of the ambulance industrys need to apply science to the design and testing of the equipment mount devices or systems used in the ambulance patient compartment
6、. The Recommended Practice was validated collaboratively by industry and government partners through extensive testing funded and managed by the National Institute for Occupational Safety and Health, the Department of Homeland Security and the Ambulance Manufacturers Division of the NTEA. Input load
7、ing for the dynamic testing was generated using the vehicle specific crash pulses described in SAE J2917 and SAE J2956, respectively. An independent analysis of the testing methodology and resulting data was performed by government and private members of the automotive testing community.1. SCOPEThis
8、 SAE Recommended Practice describes the dynamic and static testing procedures required to evaluate the integrity of an equipment mount device or system when exposed to a frontal or side impact (i.e., a crash impact). Its purpose is to provide equipment manufacturers, ambulance builders, and end-user
9、s with testing procedures and, where appropriate, acceptance criteria that, to a great extent, ensure equipment mount devices or systems meet the same performance criteria across the industry. Prospective equipment mount manufacturers or vendors have the option of performing either dynamic testing o
10、r static testing. Descriptions of the test set-up, test instrumentation, photographic/video coverage, testfixture, and performance metrics are included.2. REFERENCESThe following publications form a part of this specification to the extent specified herein. Unless otherwise indicated, thelatest issu
11、e of SAE publications shall apply.2.1 Applicable DocumentsAvailable from SAE International, 400 Commonwealth Drive, Warrendale, PA 15096-0001, Tel: 877-806-7323 (inside USA and Canada) or 724-776-4970 (outside USA), www.sae.org.SAE J211-1 Instrumentation for Impact Test - Part 1: Electronic Instrume
12、ntationSAE J211-2 Instrumentation for Impact Test - Part 2: Photographic InstrumentationSAE J2917 Occupant Restraint and Equipment Mounting Integrity - Frontal Impact System-Level Ambulance Patient CompartmentSAE J2956 Occupant Restraint and Equipment Mounting Integrity - Side Impact System-Level Am
13、bulance Patient CompartmentSAE INTERNATIONAL J3043 Issued JUL2014 Page 2 of 62.2 Related PublicationsThe following publications are provided for information purposes only and are not a required part of this SAE Technical Report.Center for Advanced Product Evaluation (CAPE) Report CTR06963 NIOSH Dyna
14、mic-Static Factor, March 22, 20133. DEFINITIONS3.1 “Dynamic Amplification Factor”: The dynamic amplification factor is a multiplier used to convert the peak dynamic load to an equivalent static load.3.2 “Equipment Mounting Device or System”: A retention system that utilizes a temporary or permanent
15、means offixation, which may have fixed or adjustable positions. Also includes all hardware provided for holding the intended device(s).3.3 “Fracture” means cracking or tearing of the equipment mount system.3.4 “Load Bearing” means any component of the equipment mounting device or system, hardware an
16、d fixtures, or litter-mounted device or system that is required to maintain the equipment in a secured position.3.5 “Load Path” means a series of load bearing components.3.6 “Mounting Hardware”: Fasteners and other associated components that are used to affix an equipment mounting device or system t
17、o the interior of an ambulance or to a litter.3.7 The “Peak Acceleration” is the maximum “g” loading for the applicable pulse corridor as described in either SAE J2917 or SAE J2956.3.8 “Test Analog/Device”: A rigid inert structure that represents the physical dimensions, weight and center of gravity
18、 in all axes of the equipment for which the mounting device or system was designed to restrain. It provides connection points to attach to the intended mounting device or system that match those found on the actual piece of equipment to be mounted in the equipment mounting device or system.3.9 The “
19、Quasi Static Applied Load (QSAL)” is the load to be applied in the static test of an equipment mounting device or system in lieu of a dynamic test. The QSAL is defined mathematically as the Equipment Weight times the Peak Acceleration times the Dynamic Amplification Factor4. DYNAMIC TEST REQUIREMENT
20、SEquipment mounting device or system shall be tested using the pulse corridors defined in SAE J2917, Occupant Restraint and Equipment Mounting Integrity Frontal Impact System-Level Ambulance Patient Compartment and/or SAE J2956, Occupant Restraint and Equipment Mounting Integrity Side Impact System-
21、Level Ambulance Patient Compartment. The equipment mounting device or system will then be evaluated in accordance with section 8. 5. DYNAMIC TEST CONDITIONSThe following conditions apply:5.1 Due to the large number of mounting locations for each mounting device or system, a rigid sled test fixture s
22、hall beused. For example, a horizontal surface would represent a countertop or floor mount while a vertical surface would represent a wall.5.2 These tests are considered destructive therefore, deformation and fracture shall be expected and consideredacceptable within the criteria of Section 8. At th
23、e option of the manufacturer, a new production equipment mounting device or system may be used in each test attitude.SAE INTERNATIONAL J3043 Issued JUL2014 Page 3 of 66. DYNAMIC TEST PROCEDURESThe equipment mounting device or system manufacturer is responsible for determining all recommended product
24、 or product mount orientations relative to the patient compartment of the ambulance. In lieu of testing all orientations, theequipment mount device or system manufacturer may determine the worst case orientation to be tested where other orientations can be shown sufficient by comparative analysis. I
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- SAEJ30432014AMBULANCEEQUIPMENTMOUNTDEVICEORSYSTEMS 救护 仪器 安装 设备 系统 PDF

链接地址:http://www.mydoc123.com/p-1027779.html