SAE J 249-1988 Mechanical Stop Lamp Switch.pdf
《SAE J 249-1988 Mechanical Stop Lamp Switch.pdf》由会员分享,可在线阅读,更多相关《SAE J 249-1988 Mechanical Stop Lamp Switch.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、SAE Technical Standards Board Rules provide that: “This report is published by SAE to advance the state of technical and engineering sciences. The use of this report is entirelyvoluntary, and its applicability and suitability for any particular use, including any patent infringement arising therefro
2、m, is the sole responsibility of the user.”SAE reviews each technical report at least every five years at which time it may be reaffirmed, revised, or cancelled. SAE invites your written comments and suggestions.QUESTIONS REGARDING THIS DOCUMENT: (412) 772-8512 FAX: (412) 776-0243TO PLACE A DOCUMENT
3、 ORDER; (412) 776-4970 FAX: (412) 776-0790http:www.sae.orgCopyright 1988 Society of Automotive Engineers, Inc.All rights reserved. Printed in U.S.A.SURFACEVEHICLE400 Commonwealth Drive, Warrendale, PA 15096-0001STANDARDSubmitted for recognition as an American National StandardJ249REV.JUN88Issued 197
4、2-02Revised 1988-06Superseding J249 FEB72(R) MECHANICAL STOP LAMP SWITCHForewordThis Document has not changed other than to put it into the new SAE Technical Standards BoardFormat.1. ScopeThe mechanical stop lamp switch is an operator activated mechanical device intended primarily tocontrol the func
5、tioning of the stop lamp and high mounted stop lamp circuits. Secondarily, the device maycontrol the functioning of various accessories, such as disengaging cruise control, with operator actuation ofbrake pedal.1.1 PurposeThis standard defines the test conditions, procedures, and performance specifi
6、cations for 6-, 12-,and 24-V manually actuated mechanical stop lamp switches.2. ReferencesThere are no referenced publications specified herein.3. Test Requirements3.1 Test Equipment and Instrumentation3.1.1 POWER SUPPLYThe power supply shall comply with the following specifications:a. Output Curren
7、tCapable of supplying the continuous and in-rush currents of the design load(reference paragraph 3.2.1.1).b. Regulation:DynamicThe output voltage at the supply shall not deviate more than 1.0 V from zero to maximumload (including in-rush current) and should recover 63% of its maximum excursion withi
8、n 100 ms.StaticThe output voltage at the supply shall not deviate more than 2% with changes in static loadfrom zero to maximum (not including in-rush current), and means shall be provided to compensate forstatic input line voltage variations.c. Ripple VoltageMaximum 300 mV peak-to-peak.SAE J249 Revi
9、sed JUN88-2-3.1.2 VOLTMETER0 30 V maximum full scale deflection, accuracy 1/2%.NOTEA digital meter having at least 3-1/2 digit readout with an accuracy of 1% plus one digit isrecommended for millivolt readings.)3.1.3 AMMETERCapable of carrying full system load current, accuracy 3%.3.2 Test Procedure
10、sEnvironmental conditions have been selected for this standard to help assure satisfactoryoperation under general customer use conditions. It is essential to duplicate specific environmental conditionsunder which the device is expected to function.3.2.1 ELECTRICAL LOADS3.2.1.1 The design load applie
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- SAEJ2491988MECHANICALSTOPLAMPSWITCHPDF