SAE J 2260-2004 Nonmetallic Fuel System Tubing with One or More Layers《一层或多层非金属燃料系统管道》.pdf
《SAE J 2260-2004 Nonmetallic Fuel System Tubing with One or More Layers《一层或多层非金属燃料系统管道》.pdf》由会员分享,可在线阅读,更多相关《SAE J 2260-2004 Nonmetallic Fuel System Tubing with One or More Layers《一层或多层非金属燃料系统管道》.pdf(36页珍藏版)》请在麦多课文档分享上搜索。
1、 SURFACE VEHICLE STANDARD Nonmetallic Fuel System Tubing with One or More Layers SAE Technical Standards Board Rules provide that: “This report is published by SAE to advance the state of technical and engineering sciences. The use of this report is entirely voluntary, and its applicability and suit
2、ability for any particular use, including any patent infringement arising therefrom, is the sole responsibility of the user.” SAE reviews each technical report at least every five years at which time it may be reaffirmed, revised, or cancelled. SAE invites your written comments and suggestions. Copy
3、right 2004 SAE International All rights reserved. No part of this publication may be reproduced, stored in a retrieval system or transmitted, in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise, without the prior written permission of SAE. TO PLACE A DOCUMENT O
4、RDER: Tel: 877-606-7323 (inside USA and Canada) Tel: 724-776-4970 (outside USA) Fax: 724-776-0790 Email: custsvcsae.org SAE WEB ADDRESS: http:/www.sae.org Issued 1996-11 Revised 2004-11 Superseding J2260 NOV1996 J2260 REV. NOV2004 1. Scope This SAE Standard presents the minimum requirements for nonm
5、etallic tubing with one or more layers manufactured for use as liquid-carrying or vapor-carrying component in fuel systems for gasoline, or alcohol blends with gasoline. Requirements in this document also apply to monowall tubing (one layer construction). When the construction has one or more layers
6、 of polymer-based compounds in the wall, the multilayer constructions are primarily for the purpose of improvement in permeation resistance to hydrocarbons found in various fuels. The tube construction can have a straight-wall configuration, a wall that is convoluted or corrugated, or a combination
7、of each. It may have an innermost layer with improved electrical conductivity for use where such a characteristic is desired. The improved electrical conductivity can apply to the entire wall construction, if the tubing is a monowall. (For elastomeric based MLT constructions, refer to SAE J30 and SA
8、E J2405). Unless otherwise agreed to by suppliers and users this document applies to tubing for any portion of the fuel system that might operate continuously at temperatures above -40 C and below 90 C and up to a maximum working gage pressure of 450kPa. The tubing can be used at the peak intermitte
9、nt temperature up to 115 C. This document can apply to systems that operate at higher pressures and/or are exposed to higher temperatures. For higher pressures, the acceptance criteria of section 7.2 must be correspondingly changed. For higher temperatures, the acceptance criteria of sections 7.2 an
10、d 7.14 remain the same, but apply at the higher temperature. The selection of higher temperatures and pressures that could be used for this document would be the decision of the end user and supplier of the specific fuel/fuel vapor system in question. There are three types of tubing covered by this
11、specification, based on the type of application for which the tubing is intended to be used: High pressure, liquid fuel line is tubing that handles liquid fuel at pressures up to 450 kPa pressure, and can handle the maximum pressure requirements identified in sections 7.1 and 7.2. These are typicall
12、y the smaller diameter tubes identified in Table A1. SAE J2260 Revised NOV2004 - 2 - Low pressure, liquid fuel line is tubing that is regularly exposed to liquid fuel, but is subjected to pressures that are under 50 kPa (e.g. fuel filler pipes). These are typically the larger diameters identified in
13、 Table A1. Fuel vapor tubing is tubing that handles fuel in vapor form or some liquid condensed from vapor, and operates at a working gauge pressure that does not exceed 20 kPa. In some cases, a distinction is made in the criteria that apply to tubing used to carry liquid fuel compared to tubing use
14、d to carry fuel vapor. These are identified separately in each section. 2. References 2.1 Applicable Publications The following publications form a part of this specification to the extent specified herein. Unless otherwise indicated, the latest issue of SAE publications shall apply. 2.1.1 SAE PUBLI
15、CATIONS Available from SAE, 400 Commonwealth Drive, Warrendale, PA 15096-0001. SAE J30Fuel and Oil Hoses (R11: Low Permeation Fuel Fill and Vent Hose and R12: Low Permeation Fuel Feed and Return Hose) SAE J1645Recommended Practice Covering Electrostatic Charge in Fuel Systems SAE J1681Gasoline, Alco
16、hol and Diesel Surrogates for Material Testing SAE J1737Recommended Practice for Measurement of Permeation Resistance by the Recirculation Technique SAE J1960Accelerated Exposure of Automotive Exterior Materials Using a Controlled Irradiance Water-Cooled Xenon-Arc Apparatus SAE J2027Standard for Pro
17、tective Covers for Gasoline Fuel Lines SAE J2044SAE Quick Connector Specifications for Liquid Fuel Systems SAE J2045Tube/Hose Assemblies SAE J2405Low Permeation Fuel Fill and Vent Tube (Elastomer Hose) SAE J2663Test Procedure to Measure Permeation of Elastomeric Hose by Reservoir Weight Loss Method
18、2.1.2 ISO PUBLICATIONS Available from ANSI, 25 West 43rd Street, New York, NY 10036-8002. ISO 527PlasticsDetermination of tensile properties ISO 4639-3Rubber tubing and hoses for fuel circuits for internal combustion engines specificationPart 3: Oxidized fuels SAE J2260 Revised NOV2004 - 3 - 2.2 Rel
19、ated Publications The following publications are for information purposes only and are not a required part of this document. 2.2.1 ASTM PUBLICATIONS Available from ASTM, 100 Barr Harbor Drive, West Conshohocken, PA 19428-2959. ASTM D 412Test Methods for Rubber Properties in Tension ASTM D 4000Classi
20、fication System for Specifying Plastic Materials ASTM D 4066Specification for Nylon Injection and Extrusion Materials 3. Installation, Assembly, and Handling Recommendation 3.1 End Fittings End fittings can be assembled to the tubing providing that they do not cause mechanical damage to the tubing t
21、hat results in decreased performance. Assemblies manufactured with tubing described in this document and end fittings must meet all of the requirements of SAE J2045. 3.2 Support and Routing When installed in a vehicle this tubing shall be routed and supported so as to: a. Prevent chafing, abrasion,
22、kinking, or other mechanical damage. b. Be protected against road hazards by installation in a protected location or by providing adequate shielding in vulnerable areas. c. Be protected from heat by proper clearance or the addition of insulation and/or heat shielding (refer to SAE J2027), for use in
23、 applications where temperatures exceed the upper limits of 115 C. 3.3 Handling Tubing ends should be protected during handling and storage to prevent internal contamination. 4. Construction Tubing shall consist of an extrudate of one or more layers within the body of the wall. The dimensions and to
24、lerances of the one or various layers shall be expressed in millimeters and the material name should be called out on the drawing. 4.1 Materials The requirements of this document apply to the tubing as a whole and not necessarily to the individual materials used in the construction of the tubing For
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- SAEJ22602004NONMETALLICFUELSYSTEMTUBINGWITHONEORMORELAYERS 一层 多层 非金属 燃料 系统 管道 PDF

链接地址:http://www.mydoc123.com/p-1026814.html