SAE J 1796-2012 Spectral Transmission Test《光谱传输试验》.pdf
《SAE J 1796-2012 Spectral Transmission Test《光谱传输试验》.pdf》由会员分享,可在线阅读,更多相关《SAE J 1796-2012 Spectral Transmission Test《光谱传输试验》.pdf(8页珍藏版)》请在麦多课文档分享上搜索。
1、_ SAE Technical Standards Board Rules provide that: “This report is published by SAE to advance the state of technical and engineering sciences. The use of this report is entirely voluntary, and its applicability and suitability for any particular use, including any patent infringement arising there
2、from, is the sole responsibility of the user.” SAE reviews each technical report at least every five years at which time it may be revised, reaffirmed, stabilized, or cancelled. SAE invites your written comments and suggestions. Copyright 2012 SAE International All rights reserved. No part of this p
3、ublication may be reproduced, stored in a retrieval system or transmitted, in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise, without the prior written permission of SAE. TO PLACE A DOCUMENT ORDER: Tel: 877-606-7323 (inside USA and Canada) Tel: +1 724-776-497
4、0 (outside USA) Fax: 724-776-0790 Email: CustomerServicesae.org SAE WEB ADDRESS: http:/www.sae.org SAE values your input. To provide feedback on this Technical Report, please visit http:/www.sae.org/technical/standards/J1796_201212 SURFACE VEHICLE STANDARD J1796 DEC2012 Issued 1995-05 Revised 2012-1
5、2Superseding J1796 MAY2005 Spectral Transmission Test RATIONALE This document is being written to standardize calculations and communications involving spectral transmission data from safety-glazing materials for road vehicles. This revised document now conforms with the computational convention “A“
6、 in ISO 13837. 1. SCOPE The scope of this SAE performance standard is to define the test method by which the direct solar and visible transmittance of safety glazing materials for road vehicles shall be measured. Adherence to this performance standard will facilitate writing, use and referencing of
7、reports by government, industry and other organizations. 1.1 Purpose The purpose of this performance standard is to determine the direct solar and visible and color transmittance of safety glazing materials for road vehicles. 1.2 Application The performance standard applies to monolithic or laminate
8、d, clear or tinted samples of safety glazing materials. Essentially flat sections of glazing parts may be used in this test as well as flat samples of the same materials. 2. REFERENCES 2.1 Applicable Documents The following publications form a part of this specification to the extent specified herei
9、n. Unless otherwise indicated, the latest issue of SAE publications shall apply. 2.1.1 ISO Publications Available from American National Standards Institute, 25 West 43rd Street, New York, NY 10036-8002, Tel: 212-642-4900, www.ansi.org. ISO 13837:2008 Road vehicles - Safety glazing materials - Metho
10、d for the determination of solar transmittance ISO 9845-1:1992(E) Solar Energy - Reference solar spectral irradiance at the ground at different receiving conditions - Part 1: Direct normal and hemispherical solar irradiance for air mass 1.5 - Table 1 - Spectral solar irradiance (column 5) SAE J1796
11、Revised DEC2012 Page 2 of 82.1.2 CIE Publications Available from CIE Central Bureau, Kegelgasse 27, A-1030 Vienna, AUSTRIA CIE Publication No. 85 Technical Report - Solar Spectral Irradiance CIE Publication 15:2004 Colorimetry, 3rd ed. 2.1.3 ASTM Publications Available from ASTM International, 100 B
12、arr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959, Tel: 610-832-9585, www.astm.org ASTM E308 (96) Standard Test Method for Computing the Colors of Objects by Using the CIE System ASTM E380-93 Practice for the use of the International System of Units (SI) (the Modernized Metric System
13、) 3. DEFINITIONS 3.1 STANDARDIZE To adjust an instrument output to correspond to a previously established calibration using one or more homogeneous specimens or reference materials. 3.2 TRANSMITTANCE The ratio of transmitted flux to incident flux, under specified geometric and spectral conditions. 3
14、.3 AIR MASS The ratio of the mass of atmosphere in the actual observer-sun path to the mass that would exist if the observer were at sea level, at standard barometric pressure, and the sun were directly overhead. 3.4 SOLAR UV TRANSMITTANCE (TUV) The transmittance weighted, interval by interval, deri
15、ved from modified ISO 9845-1, Table 1, column 5, Eg79i. (with air mass = 1.5 global)1distribution from 300 through 400 nanometers (nm) at 5 nm intervals (Table 1). 3.5 SOLAR DIRECT TRANSMITTANCE (TDS) The transmittance weighted, interval by interval, derived from modified ISO 9845-1, Table 1, column
16、 5, Eg79g76(with air mass = 1.5 global)2 distribution from 300 through 2500 (nm) at 5, 10, 50 nm intervals (Table 2). 3.6 VISIBLE LUMINOUS TRANSMITTANCE (LTA) Illuminant A spectral power distribution (2856 K correlated color temperature) multiplied by the spectral luminous efficiency function for ph
17、otopic vision (V(g79). The transmittance weighted, interval by interval, according to ASTM E308 (90), 7.1.1 and 7.2.1 (Abridged Calculation Procedure) and Table 5.1, column (y). This is nearly equivalent to CIE Publication No. 15:2004, (Table 1.1, A) times (Table 2.1, y(g79) distribution from 380 th
18、rough 780 (nm) at 10 nm intervals. NOTE: V(g79) = y(g79) (See Note 3, page 20 of CIE Publication15:2004). See Section 4.2.3.4 below. 1The TUVin modified ISO 9845-1 Table 1, column 5 is equivalent to the TUVin ISO 13837, Table 1, Eg79i. 2The TDSin modified ISO 9845-1 Table 1, column 5 is equivalent t
19、o the TDSin ISO 13837, Table 2, Eg79i. SAE J1796 Revised DEC2012 Page 3 of 83.7 COLOR TRANSMITTANCE (X, Y, Z) Illuminant D65spectral power distribution (6500 K correlated color temperature) multiplied by the CIE 1964 supplementary standard colorimetric observer (see ASTM E308 (96). The transmittance
20、 is weighted, interval by interval, according to ASTM E308 (96), Table 5.19. This is equivalent to CIE Publication No. 15:2004 (Table 1.1, D65) times (Table 2.2, x10(g79), y10(g79), z10(g79) distribution from 380 through 780 (nm) at 10 nm intervals. See Section 4.2.3.5 below. 4. TEST METHOD 4.1 Appa
21、ratus - Measuring Instrument This method requires spectral transmittance data to be obtained from samples of glazing materials using a scanning spectrophotometer. This instrument, preferably equipped with an integrating sphere, must be capable of measuring transmittance over that part of the electro
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- SAEJ17962012SPECTRALTRANSMISSIONTEST 光谱 传输 试验 PDF

链接地址:http://www.mydoc123.com/p-1026545.html