SAE J 1598-2009 Laboratory Testing of Vehicle and Industrial Heat Exchangers for Durability Under Vibration-Induced Loading《振动诱导下的载荷车辆和工业换热器耐久性的实验室测试》.pdf
《SAE J 1598-2009 Laboratory Testing of Vehicle and Industrial Heat Exchangers for Durability Under Vibration-Induced Loading《振动诱导下的载荷车辆和工业换热器耐久性的实验室测试》.pdf》由会员分享,可在线阅读,更多相关《SAE J 1598-2009 Laboratory Testing of Vehicle and Industrial Heat Exchangers for Durability Under Vibration-Induced Loading《振动诱导下的载荷车辆和工业换热器耐久性的实验室测试》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、_ SAE Technical Standards Board Rules provide that: “This report is published by SAE to advance the state of technical and engineering sciences. The use of this report is entirely voluntary, and its applicability and suitability for any particular use, including any patent infringement arising there
2、from, is the sole responsibility of the user.” SAE reviews each technical report at least every five years at which time it may be reaffirmed, revised, or cancelled. SAE invites your written comments and suggestions. Copyright 2009 SAE International All rights reserved. No part of this publication m
3、ay be reproduced, stored in a retrieval system or transmitted, in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise, without the prior written permission of SAE. TO PLACE A DOCUMENT ORDER: Tel: 877-606-7323 (inside USA and Canada) Tel: 724-776-4970 (outside USA)
4、 Fax: 724-776-0790 Email: CustomerServicesae.org SAE WEB ADDRESS: http:/www.sae.org SURFACE VEHICLE RECOMMENDED PRACTICE J1598 MAY2009 Issued 1988-07 Revised 2009-05 Superseding J1598 DEC1999 Laboratory Testing of Vehicle and Industrial Heat Exchangers for Durability Under Vibration-Induced Loading
5、RATIONALE This document has been converted to Word format and corrections have been made to spelling, punctuation, and grammar. SAE J2679, Charge Air Cooler Leakage, has been added to the list of applicable publications in section 2.1.1 and it has been specified in section 5.7 as the method of deter
6、mining leaks in charge air coolers. A suggestion to filter road cycle data has been added to section 5.3.1 to reduce test time. 1. SCOPE This SAE Recommended Practice is applicable to all liquid-to-gas, liquid-to-liquid, gas-to-gas, and gas-to-liquid heat exchangers used in vehicle and industrial co
7、oling systems. This document outlines the test to determine durability characteristics of the heat exchanger from vibration-induced loading. 1.1 Purpose This document provides a test guideline for determining the durability of a heat exchanger under specified vibration loading. 2. REFERENCES 2.1 App
8、licable Publications The following publications form a part of this specification to the extent specified herein. The latest issue of SAE publications shall apply. 2.1.1 SAE Publications Available from SAE International, 400 Commonwealth Drive, Warrendale, PA 15096-0001, Tel: 877-606-7323 (inside US
9、A and Canada) or 724-776-4970 (outside USA), www.sae.org. SAE J1542 Laboratory Testing of Vehicle and Industrial Heat Exchangers for Thermal Cycle Durability SAE J1597 Laboratory Testing of Vehicle and Industrial Heat Exchangers for Pressure-Cycle Durability SAE J2679 Charge Air Cooler Leakage Copyr
10、ight SAE International Provided by IHS under license with SAENot for ResaleNo reproduction or networking permitted without license from IHS-,-,-SAE J1598 Revised MAY2009 Page 2 of 4 3. OBJECTIVE To verify compliance with established criteria that insures durability in a specific application. This do
11、cument describes a system to induce stresses in a heat exchanger resulting from vibration loading. The process is accomplished by vibrating the unit at specified frequencies, and amplitudes or at specified frequencies and acceleration. 4. FACILITY REQUIREMENT The facility should provide the followin
12、g as required: 4.1 Vibration equipment with controls on frequency, amplitude, and acceleration (for 50 Hz and below, electrohydraulic is suggested, higher frequencies may require electrodynamic). 4.2 Test Fixture 4.2.1 Actual Installation 4.2.2 If actual installation is not available, a fixture shou
13、ld support the heat exchanger with orientation as in service or as specified. The fixture must be rigid so as not to induce any additional dynamic inputs. 4.3 Means of checking heat exchanger integrity. 4.4 Equipment to monitor motion of unit during test. 4.5 Source for pressurizing and heating test
14、 unit if required. 4.6 Additional equipment may include but not be limited to the following: a. Accelerometers b. Automatic data logging equipment c. Automatic emergency shutdown d. Cycle counters e. Digital signal analyzer f. Function generator (sine wave, random noise, square wave, ramp function,
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- SAEJ15982009LABORATORYTESTINGOFVEHICLEANDINDUSTRIALHEATEXCHANGERSFORDURABILITYUNDERVIBRATIONINDUCEDLOADING

链接地址:http://www.mydoc123.com/p-1026405.html