SAE J 1076-1990 Backup Lamp Switch Standard《倒车灯开关 标准 1990年3月》.pdf
《SAE J 1076-1990 Backup Lamp Switch Standard《倒车灯开关 标准 1990年3月》.pdf》由会员分享,可在线阅读,更多相关《SAE J 1076-1990 Backup Lamp Switch Standard《倒车灯开关 标准 1990年3月》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、SAE Technical Standards Board Rules provide that: “This report is published by SAE to advance the state of technical and engineering sciences. The use of this report is entirelyvoluntary, and its applicability and suitability for any particular use, including any patent infringement arising therefro
2、m, is the sole responsibility of the user.”SAE reviews each technical report at least every five years at which time it may be reaffirmed, revised, or cancelled. SAE invites your written comments and suggestions.QUESTIONS REGARDING THIS DOCUMENT: (724) 772-8512 FAX: (724) 776-0243TO PLACE A DOCUMENT
3、 ORDER; (724) 776-4970 FAX: (724) 776-0790SAE WEB ADDRESS http:/www.sae.orgCopyright 1990 Society of Automotive Engineers, Inc.All rights reserved. Printed in U.S.A.SURFACEVEHICLE400 Commonwealth Drive, Warrendale, PA 15096-0001STANDARDSubmitted for recognition as an American National StandardJ1076R
4、EV.MAR90Issued 1974-02Revised 1990-03-16Superseding J1076 FEB74(R) BACKUP LAMP SWITCH1. ScopeThis standard defines the test conditions, procedures and performance specification for 6, 12, and 24V backup lamp switches which are intended for use in motor vehicles.2. ReferencesThere are no referenced p
5、ublications specified herein.3. DefinitionsThe backup lamp switch is an operator activated device intended primarily to control the functionof the backup lamps. There are three types:3.1 Type “A“A transmission mounted backup lamp switch is that device which is mounted in or on thetransmission and ac
6、tuated by a moving part within the transmission that energizes the backup lamps when thetransmission is shifted into reverse.3.2 Type “B“A backup lamp switch performing the same function as Type “A“, except that it is operated by amechanism external of the transmission but not mounted in the passeng
7、er compartment.3.3 Type “C“A backup lamp switch performing the same function as Type “A“ but mounted in the passengercompartment and actuated by movement of the shift mechanism or linkage.4. Test4.1 Test Equipment and Instrumentation4.1.1 POWER SUPPLYThe power supply shall comply with the following
8、specifications:a. Output current - capable of supplying the continuous and inrush currents of the design load .b. Regulation:1. Dynamic: The output voltage at the supply shall not deviate more than 1.0 V from zero to maximumload (including inrush current) and should recover 63% of its maximum excurs
9、ion within 100 ms.2. Static: The output voltage at the supply shall not deviate more than 2% with changes in static loadfrom zero to maximum (not including inrush current), and means shall be provided to compensatefor static input line variations.c. Ripple Voltage - maximum 300 mV peak to peak.4.1.2
10、 VOLTMETER0 30 V maximum full scale deflection, accuracy 1/2%.SAE J1076 Revised MAR90-2-NOTEA digital meter having at least a 3-1/2 digit readout with an accuracy of 1% plus 1 digit isrecommended for mV readings.4.1.3 AMMETERCapable of carrying full system load current, accuracy 3%.4.2 Test Procedur
11、esEnvironmental conditions have been selected for this document to help assure satisfactoryoperation under general customer use conditions. It is essential to duplicate specific environmental conditionsunder which the device is expected to function.4.2.1 ELECTRICAL LOADS4.2.1.1 The design load appli
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- SAEJ10761990BACKUPLAMPSWITCHSTANDARD 车灯 开关 标准 1990 PDF

链接地址:http://www.mydoc123.com/p-1026100.html