SAE AS 81587-2000 Timer Assembly Rain Repellent《FSC 6630定时器组件排雨剂 应代替2000年6月20日作废的MIL-T-81587A(AS)标准》.pdf
《SAE AS 81587-2000 Timer Assembly Rain Repellent《FSC 6630定时器组件排雨剂 应代替2000年6月20日作废的MIL-T-81587A(AS)标准》.pdf》由会员分享,可在线阅读,更多相关《SAE AS 81587-2000 Timer Assembly Rain Repellent《FSC 6630定时器组件排雨剂 应代替2000年6月20日作废的MIL-T-81587A(AS)标准》.pdf(11页珍藏版)》请在麦多课文档分享上搜索。
1、SAE-AS81587ADOPTION NOTICESAE-AS81587, “TIMER ASSEMBLY RAIN REPELLENT“, was adopted on20-JUN-00 for use by the Department of Defense (DoD). Proposedchanges by DoD activities must be submitted to the DoD AdoptingActivity: Commander, Naval Air Warfare Center, Aircraft Division,Code 414100B120-3, Highw
2、ay 547, Lakehurst, NJ 08733-5100. Copiesof this document may be purchased from the Society of AutomotiveEngineers 400 Commonwealth Drive Warrendale, Pennsylvania, UnitedStates, 15096-0001. http:/www.sae.org/_Custodians: Adopting Activity:Navy - ASNavy - ASFSC 6630DISTRIBUTION STATEMENT A: Approved f
3、or public release; distributionis unlimited.SAE Technical Standards Board Rules provide that: “This report is published by SAE to advance the state of technical and engineering sciences. The use of this report is entirelyvoluntary, and its applicability and suitability for any particular use, includ
4、ing any patent infringement arising therefrom, is the sole responsibility of the user.”SAE reviews each technical report at least every five years at which time it may be reaffirmed, revised, or cancelled. SAE invites your written comments and suggestions.Copyright 2000 Society of Automotive Enginee
5、rs, Inc.All rights reserved. Printed in U.S.A.TO PLACE A DOCUMENT ORDER: (724) 776-4970 FAX: (724) 776-0790SAE WEB ADDRESS: http:/www.sae.org400 Commonwealth Drive, Warrendale, PA 15096-0001AEROSPACE STANDARDAS81587Issued 2000-03Timer Assembly Rain RepellentFSC 6630NOTICEThis document has been taken
6、 directly from U.S. Military Specification MIL-T-81587A(AS), Notice 1 and contains only minor editorial and format changes required to bring it into conformance with the publishing requirements of SAE technical standards. The initial release of this document is intended to replace MIL-T-81587A(AS),
7、Notice 1. Any part numbers established by the original specification remain unchanged.The original Military Specification was adopted as an SAE standard under the provisions of the SAE Technical Standards Board (TSB) Rules and Regulations (TSB 001) pertaining to accelerated adoption of government sp
8、ecifications and standards. TSB rules provide for (a) the publication of portions of unrevised government specifications and standards without consensus voting at the SAE Committee level, and (b) the use of the existing government specification or standard format.Under Department of Defense policies
9、 and procedures, any qualification requirements and associated qualified products lists are mandatory for DOD contracts. Any requirement relating to qualified products lists (QPLs) has not been adopted by SAE and is not part of this SAE technical document.SAE AS81587 - 2 -1. SCOPE:This specification
10、 covers the requirements for an interval timer for controlling the duration of an electrical pulse to a solenoid valve for use in Rain Repellent systems covered by SpecificationMIL-R-81589.2. APPLICABLE DOCUMENTS:2.1 The following documents, of the issue in effect on the date of invitation for bids,
11、 form a part of this specification to the extent specified herein:SpecificationsMilitaryMIL-C-5015 Connectors, Electric, “AN” TypeMIL-E-5272 Environmental Testing, Aeronautical and Associated Equipment, General Specification forMIL-E-5400 Electrical Equipment, Airborne, General Specification forMIL-
12、E-17555 Electronic and Electrical Equipment and Associated Repair Parts, Preparation for delivery ofMIL-R-81589 Rain Repellent Fluid Application System, Aircraft WindshieldFederalPPP-T-0060 Tape, Pressure Sensitive Adhesive-Water ProofStandardsMIL-STD-105 Sampling Procedures and Tables for Inspectio
13、n by AttributesMIL-STD-129 Marking for Shipment and StorageMIL-STD-130 Identification Marking of U.S. Military PropertyMIL-STD-171 Finishing of Metal and Wood SurfacesMIL-STD-454 Standard General Requirements for Electronic EquipmentMIL-STD-461 Electromagnetic Interference Characteristics, Requireme
14、nts for EquipmentMIL-STD-704 Electric Power, Aircraft, Characteristics and Utilization ofMIL-STD-831 Test Reports, preparation ofMS-3102 Connector, Receptacle, Electric Box MountingMS-3106 Connector, Plug, Electric, StraightMS-29527 Valve, Fuel Shut Off, Solenoid Operated 28 Volts DC(Copies of speci
15、fications, standards, drawings and publications required by contractors in connection with specific procurement functions should be obtained from the procuring activity or as directed by the contracting officer.)SAE AS81587 - 3 -3. REQUIREMENTS:3.1 Preproduction:This specification makes provision fo
16、r preproduction testing.3.2 Parts and Materials:Approval for the use of non-standard parts and materials other than microelectronic devices shall be based on Category II of Specification MIL-E-5400.3.2.1 Non-Standard Semiconductors: Approval for the use of non-standard and non-preferred semiconducto
17、rs shall be in accordance with Military Standard MIL-STD-454, Requirement 30.3.2.2 Vacuum Tubes: No vacuum tubes shall be used.3.3 Design and Construction:The timer shall be a complete, self-contained unit consisting of an interval timing circuit, electro-mechanical or solid state, a connecting rece
18、ptacle and an enclosure. Design shall conform to the requirements of Specification MIL-E-5400. Workmanship shall conform to Military StandardMIL-STD-454, Requirement 9. Electromagnetic relays shall comply with Military StandardMIL-STD-454, Requirement 57.3.3.1 Weight: The total weight of the timer s
19、hall be a minimum consistent with good design and shall not exceed 0.5 pound.3.3.2 Container: The timing circuit shall be enclosed in an aluminum alloy container cylindrical in form with a maximum outside diameter of 1-3/4 inches and a maximum length of 2-5/8 inches, not including the connector. The
20、 container shall be finished in accordance with Finish Numbers 7.1.1 plus 21.3 of Military Standard MIL-STD-171, Black No. 27038. A 1/4 inch diameter hole may be provided in the container for access to the timer adjustment. The hole shall be covered with pressure sensitive, water-proof, adhesive tap
21、e, Specification PPP-T-0060, Type I, Class I and sealed with one coat of shellac.3.3.3 Operating Power: The timer shall provide the specified performance when energized from a 28 volt d.c. power source with power characteristics conforming to Military Standard MIL-STD-704 for Category B utilization
22、equipment. The electrical load for the timer operation is defined by solonoid valve, Military Standard MS-29527-1.3.3.4 Timing Circuit: The timing circuit shall provide a 28 volt d.c. pulse to a solenoid valve which conforms to Military Standard MS-29527-1. A single timed pulse shall be initiated by
23、 a 28 volt d.c. electrical pulse not longer than 0.5 second duration. The timed pulse from the timer shall be adjustable from 1.0 to 5.0 seconds. The timer adjustment shall be accessible with the timer assembled. The timer shall not be capable of automatic recycling. The timer shall be set by the co
24、ntractor to the time interval specified in the procurement document.SAE AS81587 - 4 -3.3.5 Electrical Connection: The timer shall be equipped with a receptacle conforming to Military Standard MS-3102R-14S-5P in accordance with Specification MIL-C-5015. The receptacle shall be securely attached to th
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- SAEAS815872000TIMERASSEMBLYRAINREPELLENTFSC6630 定时器 组件 排雨剂应 代替 2000 20 作废 MILT81587AAS 标准 PDF

链接地址:http://www.mydoc123.com/p-1025439.html