《SAE AS 8021-1981 Minimum Performance Standards for Direction Instrument Non-Magnetic (Gyroscopically Stabilized)《(陀螺平衡的)非磁方向仪的最低性能标准R(1991)》.pdf》由会员分享,可在线阅读,更多相关《SAE AS 8021-1981 Minimum Performance Standards for Direction Instrument Non-Magnetic (Gyroscopically Stabilized)《(陀螺平衡的)非磁方向仪的最低性能标准R(1991)》.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、SAE AS*:802L BL 83573LtO 003L1LLt5 Lt M however, the heading error involved through the gimbal system need not be corrected. 3.10 Dial Markings: 3.10.1 Graduations: The indicators shall be provided with degree graduations at intervals not to exceed five (5) degrees, with major graduations every ten
2、(10) degrees and with numerals at intervals not greater than 30 degrees, except that the O, 90, 180, and 270 degrees positions may be marked N, E, S, and W, respectively. 3.10.2 Visibility: Index and dial markings shall be visible from any point within the upper half of a frustum of a cone, the side
3、 of which makes an angle of at least 30 degrees with the perpendicular to the dial and the small diameter of which is the aperture of the instrument case. At least two numerals shall be simultaneously visible. 3,11 Caging Provisions: Unless the gyro assembly has restricted freedom of operation in th
4、e pitch and roll axes, a means shall be provided for caging and/or releveling the gyro. shall be provided to indicate when the gyro is caged, except when it is not possible to leave the gyro in the caged condition, A means 3.12 Course S.etting Provisions: A means shall be provided for manually setti
5、ng the directional in- dicator to any heading desired. Copyright SAE International Provided by IHS under license with SAENot for ResaleNo reproduction or networking permitted without license from IHS-,-SAE AS*021 81 M 83573L)O 003Lt147 8 U -3- I AS SO21 4. MINIMUM PERFORMANCE REQUIREMENTS UNDER STAN
6、DARD TEST CONDITIONS : 4.1 4.2 4.3 Starting: normal power is applied for both air and electric operated instruments. 50 percent of rated vacuum or pressure for air operated instruments and 80 percent of rated voltage for eIectrically operated instruments, the gyro rotor shail start and continue to r
7、otate. If the instrument incorporates a gyro speed monitoring device which provides a positive indicatioi when the gyro speed is below that necessary to meet instrument performance, the starting time may exceed three minutes, but shall not be greater than five minutes. Rated instrument performance r
8、otor speed shall be achieved wit4iin three minutes after By application of Roll, Pitch and Yaw: oscillate in roll, pitch and yaw, with a total amplitude of 3 degrees about each axis, at a frequency of 5 to 7 oscillations per minute while reversing the direction of rotation every 6 revolutions. the d
9、ial reading shall be noted. movement. At the end of a ten minute period the oscillation shall be stopped, the platform realigned to its starting position, and the instrument dial reading noted. of the dial in either direction during the ten minute test period shall not exceed 4 degrees. This test sh
10、all be run four times with the instrument case rotated 90 with respect to the outer gimbal between each test. The instrument shall be mounted on a test .platform which is adjusted to With the platform level, and the gyro operating at equilibrium speed and uncaged The platform shall then be started i
11、n its roll, pitch and yaw The amount of drift Heading Stablity: the vertical and the reading noted. The turn table shall be rotated one complete revolution about its axis at 360 (230) degrees per minute and the drift of the dial shall not exceed two degrees. The instrument shall be mounted on a turn
12、 table, tilted 54 (21) degrees from The test shall be repeated rotating the turn table in the opposite direction. 5. MINIMUM PERFORMANCE REQUIREMENTS UNDER ENVIRONMENTAL CONDITIONS : Unless otherwise specified herein , the procedures applicable to a determination of the performance of directional in
13、struments under environmental conditions are set forth in Radio Technical Com- mission for Aeronautics (RTCA) mcument No. DO- 160, entitled “Environmental Conditions and Test Procedures for Airborne Electronic/Electrical Equipment. and hstrumentstt, dated February 1975. Performance tests specified a
14、fter subjection to test environments may be made after exposure to several environmental conditions. The order of tests shail be in accordance with paragraph 3.2, page 4, of DO-160. for use in determining the performance of directional instruments under standard and extreme environmental conditions.
15、 Alternate approved test procedures that provide equivalent results may be used. Will comply with the requirements of this paragraph, shall be tested in accordance with the manufacturers recommendations. The test .procedures specified or referenced are satisfactory As many instruments as deemed nece
16、ssary to demonstrate that all instruments 5.1 Performance Standard for Use During Environmental Tests: shall be used when performance testing during an environmental test is required: The foilowing performance standard (a) There shall be no more than five degrees drift in either direction during a t
17、en minute . period. Roll, pitch, and yaw motion is not required for this test. 5.2 Temperature - Altitude - Humidity : (a) Low-Temperature - The instrument shall be subjected to the tests of DO-160, para- graph 4.4. During the test, the instrument shall operate electrically and mechanically and the
18、requirements of paragraph 5.1 of this Standard shall be met. test, the requirements of paragraph 4.0 of this Standard shall be met at standard conditions. Foilowing the 1 Copyright SAE International Provided by IHS under license with SAENot for ResaleNo reproduction or networking permitted without l
19、icense from IHS-,-SAE AS*B02L BI = 8357340 0034L48 T = I AS 8021 I -4- I (b) High Temperature - The instrument shall be subjected to the tests of DO-160, paragraph 4.5.1 and 4.5.2. operateelectrically and mechanically and there shall be no evidence of materials such as potting and sealing compounds
20、exuding or dripping from the instrument, When subjected to the tests of paragraph 4.5.2, the instrument shall operate electrically and mechanically and the requirements of paragraph 5.1 of this Standard shaU be met. Following the test, the requirements of paragarph 4.0 of this Standardshali be met a
21、t standard conditions. During the test, paragraph 4.5.1, the instrument shall (c) Altitude - The instrument shall be subjected to the tests of DO-160, paragraphs 4.6.1, 4.6.2, and 4.6.3. During the test, paragraph 4.6.1, the instrument shaU operate electrically and mechanically and the requirements
22、of paragraph 5.1 of this Standard shall be met. After being subjected to the tests of paragraph 4.6.2, the requirements of paragraph 4. O of this Standard shall be met at standard conditions, and after being subjected to the tests of paragraph 4.6.3, the requirements of paragraph 4.0 shall be met. (
23、d) Humidity - The instrument shall be subjected to the tests of DO-160, paragraph 6.0. After the instrument is subjected to the appropriate tests of paragraph 6.0, it shall meet the requirements of paragraph 4.0 of this Standard at standard conditions. 5.3 5.4 5.5 Shock: The instrument shall be subj
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- SAEAS80211981MINIMUMPERFORMANCESTANDARDSFORDIRECTIONINSTRUMENTNONMAGNETICGYROSCOPICALLYSTABILIZED 陀螺

链接地址:http://www.mydoc123.com/p-1025371.html