1、_ SAE Technical Standards Board Rules provide that: “This report is published by SAE to advance the state of technical and engineering sciences. The use of this report is entirely voluntary, and its applicability and suitability for any particular use, including any patent infringement arising there
2、from, is the sole responsibility of the user.” SAE reviews each technical report at least every five years at which time it may be revised, reaffirmed, stabilized, or cancelled. SAE invites your written comments and suggestions. Copyright 2013 SAE International All rights reserved. No part of this p
3、ublication may be reproduced, stored in a retrieval system or transmitted, in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise, without the prior written permission of SAE. TO PLACE A DOCUMENT ORDER: Tel: 877-606-7323 (inside USA and Canada) Tel: +1 724-776-497
4、0 (outside USA) Fax: 724-776-0790 Email: CustomerServicesae.org SAE WEB ADDRESS: http:/www.sae.org SAE values your input. To provide feedback on this Technical Report, please visit http:/www.sae.org/technical/standards/AIR1392A AEROSPACE INFORMATION REPORT AIR1392 REV. A Issued 1977-10 Revised 1998-
5、12 Reaffirmed 2013-12 Superseding AIR1392 Oxygen System Maintenance Guide RATIONALE AIR1392A has been reaffirmed to comply with the SAE five-year review policy. FOREWORDChanges in this revision are format/editorial only.1. SCOPE:This document is intended to give general instructions and directions f
6、or personnel performing maintenance and modification work on Oxygen Systems.2. REFERENCES:2.1 FAA/DOT Specifications and Documents Applicable to Aircraft Oxygen Systems:Advisory Circular 43.13-2 Oxygen System Installation2.2 SAE Documents Applicable to Aircraft Oxygen Systems:2.2.1 Aerospace Standar
7、ds (AS):AS861 Minimum General Standards for Oxygen Systems2.2.2 Aerospace Information Reports (AIR):AIR822 Oxygen Systems for General Aviation AircraftAIR825A Oxygen Equipment for AircraftAIR1059 Transfilling and Maintenance of Oxygen CylindersAIR1176 Oxygen System and Component Cleaning and Packagi
8、ngAIR1223 Installation of Liquid Oxygen Systems in Civil Aircraft3. SAFETY:The use of oxygen and oxygen systems involves a certain degree of hazard. With the proper design, installation, and maintenance, this hazard can be reduced to an acceptable level.Oxygen in gaseous or liquid form is chemically
9、 stable and nonflammable. However, combustible materials ignite more rapidly and the intensity of a fire increases tremendously in an oxygen-rich atmosphere.A major factor in oxygen systems is cleanliness. This is most important in fabrication, installation, and maintenance of equipment. From the in
10、stallation standpoint, the hazards of contamination should be minimized, if not completely eliminated, by choosing proper locations for the equipment and by adequate precautions and shielding where choice of location is limited.4. INSTALLATION:Care should be taken in the installation of the oxygen s
11、ystem. Protect all lines and fittings from any unnecessary abuse or scratches during installation. Low pressure aluminum alloy plumbing lines are likely to become damaged; therefore, installation and location should be so accomplished as to prevent oxygen equipment or plumbing from subjection to vib
12、ration, abrasion, or damage during other maintenance operations. All oxygen system lines, after installation, should be carefully inspected for damage and leakage. Leak testing can be accomplished by introducing the oxygen pressure into the system and examining connections by the use of a leak detec
13、tion solution specifically approved for oxygen service. Before any oxygen system component is removed or any connection is loosened, oxygen system pressure should first be dissipated.5. EQUIPMENT HANDLING:All oxygen equipment should be handled with care to avoid association with hydrocarbons such as
14、 fuels and lubricants which are ever present where aircraft are serviced and/or maintained. Because most oxygen components are of an intricate nature and all require cleanliness for proper operation, they should be kept in their original containers or be provided with a proper protective covering un
15、til ready for installation in the aircraft. This is also necessary when any of the items from an aircraft are removed for service and/or overhaul. Keep protective caps in position on equipment as long as possible and replace as soon as possible. Do not tamper with safety device or mar identifying ma
16、rkings or symbols and/or nameplates.SAE INTERNATIONAL AIR1392A Page 2 of 6_6. MODIFICATION INSTALLATION:When oxygen equipment is modified and/or replaced with new or different equipment, the following should be taken into consideration prior to making the actual installation:The oxygen equipment, tu
17、bing, and fittings shall be located as remotely as practicable from fuel, oil, hydraulic fluid, storage batteries, exhaust sacks and manifolds, electrical radios, and insulating materials. Insofar as practical, oxygen lines should not be grouped with lines carrying flammable fluids. Where necessary,
18、 deflector plates should be used to keep flammable fluids away from oxygen lines and equipment. Components of any oxygen system should not be installed where they will be subjected to temperatures in excess of that specified in the individual component specifications, and no part of the system shall
19、 be installed in an area which will be subjected to a temperature of 180 F (82 C) or greater.7. CLEARANCE REQUIREMENTS:Wherever possible oxygen lines, fittings, and equipment shall be installed above and at least 6 inches (152.4 mm) away from fuel, oil, and hydraulic systems to avoid contamination.
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- SAEAIR1392A1998OXYGENSYSTEMMAINTENANCEGUIDE 氧气 系统维护 指南 PDF

链接地址:http://www.mydoc123.com/p-1020021.html