NAVY WW-P-541 E (1)-1990 PLUMBING FIXTURES (GENERAL SPECIFICATION) [Use In Lieu Of NAVY WW-P-00541 C]《水管固定装置(一般规格)[使用代替 海军 WW-P-00541 C]》.pdf
《NAVY WW-P-541 E (1)-1990 PLUMBING FIXTURES (GENERAL SPECIFICATION) [Use In Lieu Of NAVY WW-P-00541 C]《水管固定装置(一般规格)[使用代替 海军 WW-P-00541 C]》.pdf》由会员分享,可在线阅读,更多相关《NAVY WW-P-541 E (1)-1990 PLUMBING FIXTURES (GENERAL SPECIFICATION) [Use In Lieu Of NAVY WW-P-00541 C]《水管固定装置(一般规格)[使用代替 海军 WW-P-00541 C]》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、WW-P-54LE (1) 45 = 999997L1 O054053 T WW-P-541 E/GEN AMENDMENl.-l 16 April 1990 FEDERAL SPECIFICATION PLUMBING FIXTURES (GENERAL SPECIFICATION) This amendment, which forms a part of WW-P-541E/GEN, dated August 1, 1980, is approved by the Commissioner, Federal Supply Service, General Services Adminis
2、tration, for the use of all Federal Agencies. Page 1 Paragraph 2.1 DELETE: WW-S-1912 - Seat Water CLoset (Land Use) ADD: A-A-238 - Seat, Water Closet Page 2 Paragraph 2.1 DELETE: MIL-F-19017 - Fitting, Plumbing, Water Closet CHANGE: MIL-V-29193, title to read: “Valve, Flush (Flushometer), Water .a C
3、loset, Urinal, and Service Sink“ Paragraph 2.2 DELETE: ANSI A112.6.1, A112.18.1, A112.19.1M, A112.19.2, A112.19.3, A112.19.4 ADD : ANSI A112.6.1M, A112.19.2M, A112.19.4M CHANGE: ANSI 816.23, title to read: “Cast Copper Alloy Solder Joint Drainage Fittings - DWV“ CHANGE: ANSI 2124.2, title to read: “
4、Plastic Shower Receptor and Shower Sta1 1 s“ FSC 4510 DISTRIBUTION STAIEMENT A. Approved for public release; distribution is unlimited. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-WW-P-541 E/GEN ADD : American Society of Mechanical Engineers (ASM
5、E) ASME A112.18.1M - Plumbing Fixture Fittings ASME A112.19.1M - Enameled Cast Iron Plumbing Fixtures ASME A112.19.3M - Stainless Steel Plumbing Fixtures (Designed for Residential Use) (Application for copies should be addressed to the American Society of Mechanical Engineers, United Engineering Cen
6、ter, 345 East 47th Street, New York, NY 10017.) DELETE: ASTM B 287 - Acetic Acid-Salt Spray (Fog) Testing ADD : ASTM G 85 - Modifed Salt Spray (Fog) Testing, Practice for CHANGE: ASTM F 409, title to read: “Thermoplastic Accessible and Replaceable Plastic Tube and Tubular Fittings“ Page 3 Paragraph
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NAVYWWP541E11990PLUMBINGFIXTURESGENERALSPECIFICATIONUSEINLIEUOFNAVYWWP00541C 水管 固定 装置 一般 规格 使用 代替 海军

链接地址:http://www.mydoc123.com/p-984891.html