NAVY UFGS-28 31 33 13 20-2006 EXTERIOR FIRE REPORTING SYSTEM RADIO TYPE《射频型外部火灾报告系统》.pdf
《NAVY UFGS-28 31 33 13 20-2006 EXTERIOR FIRE REPORTING SYSTEM RADIO TYPE《射频型外部火灾报告系统》.pdf》由会员分享,可在线阅读,更多相关《NAVY UFGS-28 31 33 13 20-2006 EXTERIOR FIRE REPORTING SYSTEM RADIO TYPE《射频型外部火灾报告系统》.pdf(40页珍藏版)》请在麦多课文档分享上搜索。
1、 *USACE / NAVFAC / AFCESA / NASA UFGS-28 31 33.13 20 (April 2006)-Preparing Activity: NAVFAC Replacing without change UFGS-13853N (August 2003)UNIFIED FACILITIES GUIDE SPECIFICATIONSReferences are in agreement with UMRL dated July 2010*SECTION TABLE OF CONTENTSDIVISION 28 - ELECTRONIC SAFETY AND SEC
2、URITYSECTION 28 31 33.13 20EXTERIOR FIRE REPORTING SYSTEM, RADIO TYPE04/06PART 1 GENERAL1.1 REFERENCES1.2 RELATED REQUIREMENTS1.2.1 Continuity of Protection1.3 SYSTEM DESIGN1.4 SUBMITTALS1.5 DRAWINGS1.5.1 System Layout Drawings1.5.2 Wiring Diagrams1.5.3 Mounting Details1.6 ALARM SYSTEM POWER CALCULA
3、TIONS1.7 FIRE ALARM SYSTEM UL OR FM LISTING1.8 QUALIFICATIONS1.8.1 List of Prior Installations1.8.2 Manufacturers Technical Representative1.9 SYSTEM AS-BUILT DRAWINGS1.10 QUALITY ASSURANCE1.10.1 Qualifications of Installer1.10.2 Manufacturers Technical Representative1.10.3 Qualification of System Te
4、chnicianPART 2 PRODUCTS2.1 RADIO ALARM TRANSMITTERS2.1.1 Transmitter Identity Code2.1.2 Environmental Operating Requirements2.1.3 RF Power Output2.1.4 Memory2.1.5 Transmission Confirmation2.1.6 Automatic Test2.1.7 Battery Monitoring2.1.8 Inputs/Zone Connections2.1.8.1 Zone Annunciation2.1.8.2 Zone D
5、isconnecting MeansSECTION 28 31 33.13 20 Page 1Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-2.1.8.3 Monitoring for Integrity2.1.9 Trouble Annunciator2.1.10 Transmitter Power Source2.1.11 Transmitter Enclosure2.1.11.1 Security2.1.12 Antennas and Ca
6、bles2.1.13 Lightning Protection2.1.14 Moisture Protection2.2 RADIO MASTER BOXES2.2.1 Signal Designations2.2.1.1 Tamper2.2.1.2 Fire2.2.1.3 Master2.2.1.4 Medical Emergency2.2.1.5 Police Emergency2.2.2 Housing (Enclosure)2.2.2.1 Operating Panel2.2.2.2 Interface Device for Master Box Radio Transmitters2
7、.3 RADIO STREET BOXES2.3.1 Signal Designations2.3.1.1 Tamper2.3.1.2 Fire2.3.1.3 Medical Emergency2.3.1.4 Police Emergency2.3.2 Power Source2.3.2.1 Photovoltaic Power System2.3.3 Housing (Enclosure)2.3.3.1 Operating Panel2.4 MANUAL FIRE ALARM BOXES2.5 BOX LOCATION LIGHT2.5.1 Box Location Marker (Non-
8、Electric)2.6 BASE STATION RECEIVING OR CONTROL EQUIPMENT2.6.1 Display2.6.2 Memory2.6.2.1 Memory Readout2.6.3 Digital Clock2.6.4 Printer2.6.5 Audible Annunciation2.6.6 Receivers2.6.7 Decoders2.6.8 Primary Power Source2.6.9 Emergency Power Source2.6.9.1 Emergency Power Switchover2.6.10 Network Battery
9、 Charger2.6.11 Monitoring for Network Integrity2.6.11.1 Receiver Monitoring for Integrity2.6.11.2 Power Monitoring for Integrity2.6.11.3 Meters2.6.12 Component Connections2.6.13 Protective Finish2.6.14 Base Station Receiving or Control Network Antennas2.6.15 Lightning Protection2.6.16 Field Programm
10、ing Capability2.7 COMPUTER-AIDED DISPATCH (CAD) SYSTEM2.7.1 Interconnection to Alarm System2.7.2 Monitor and Keyboard2.7.3 Printer2.7.4 Automatic Display2.7.5 Manual Alarm Entry CapabilitySECTION 28 31 33.13 20 Page 2Provided by IHSNot for ResaleNo reproduction or networking permitted without licens
11、e from IHS-,-,-2.7.6 Unit Status Tracking Capability2.7.7 Pre-Incident Plan Retrieval2.7.8 Hazardous Materials Data Retrieval2.7.9 Power Source2.7.9.1 Uninterruptible Power Supply (UPS)2.8 INTERCONNECTION WITH EXISTING COMPUTER-AIDED DISPATCH (CAD) SYSTEM2.8.1 Interconnection to Alarm Reporting Syst
12、em2.9 SURGE SUPPRESSION2.10 RADIO ALARM TRANSMITTER BATTERY CONDITIONER2.10.1 Capacity2.10.2 Meter2.11 RADIO ALARM TRANSMITTER BATTERY LOAD TESTER2.12 SAFETY DISCONNECT SWITCH2.13 PROTECTED PREMISES CONTROL UNITS2.13.1 Fire Alarm Control Units2.13.2 Fire Suppression/Extinguishing System Control Unit
13、s2.13.3 Fire Pump Control Units2.14 DRY CONTACT INITIATING DEVICES2.14.1 Sprinkler Waterflow Alarm Initiating Devices2.14.2 Fire Extinguishing System Discharge Alarm Initiating Devices2.14.3 Valve Position Supervisory Initiating Devices2.14.4 Pressure Supervisory Initiating Devices2.14.5 Temperature
14、 Supervisory Signal Initiating Devices2.14.6 Water Level Supervisory Signal Initiating Devices2.15 CONDUIT2.15.1 Rigid Steel Conduit2.15.2 Intermediate Metal Conduit (IMC)2.15.3 Electrical Metallic Tubing (EMT)2.15.4 Surface Metal Raceway and Fittings2.16 OUTLET BOXES2.17 FITTINGS FOR CONDUIT AND OU
15、TLET BOXES2.18 WIRING2.19 GROUND RODS2.20 SPARE PARTSPART 3 EXECUTION3.1 RADIO FREQUENCY ASSIGNMENT3.2 INSTALLATION3.2.1 Conductor Identification3.2.2 Conduit Installation3.2.3 Additional Installation Requirements3.3 PROGRAMMING3.3.1 Programming Revisions During Preliminary Testing3.3.2 Programming
16、Revisions During the Final Acceptance Stage3.4 FIELD TESTING3.4.1 Tests During Installation3.4.2 Final Acceptance Test3.5 ADDITIONAL TESTS3.6 INSTRUCTION OF GOVERNMENT PERSONNEL3.6.1 Instruction of Operating Personnel3.6.2 Instruction of Maintenance Personnel3.6.3 Advanced Maintenance Training- End
17、of Section Table of Contents -SECTION 28 31 33.13 20 Page 3Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-*USACE / NAVFAC / AFCESA / NASA UFGS-28 31 33.13 20 (April 2006)-Preparing Activity: NAVFAC Replacing without change UFGS-13853N (August 2003)U
18、NIFIED FACILITIES GUIDE SPECIFICATIONSReferences are in agreement with UMRL dated July 2010*SECTION 28 31 33.13 20EXTERIOR FIRE REPORTING SYSTEM, RADIO TYPE04/06*NOTE: This guide specification covers the requirements for a complete base-wide radio fire reporting system which provides reporting of fi
19、re alarms to a central processing location through the use of radio transmitters connected to various building interior fire alarm systems and optional manual exterior alarm transmitters “street boxes“.Edit this guide specification for project specific requirements by adding, deleting, or revising t
20、ext. For bracketed items, choose applicable items(s) or insert appropriate information.Remove information and requirements not required in respective project, whether or not brackets are present.Comments and suggestions on this guide specification are welcome and should be directed to the technical
21、proponent of the specification. A listing of Technical Proponents, including their organization designation and telephone number, is on the Internet.Recommended changes to a UFGS should be submitted as a Criteria Change Request (CCR).*NOTE: Interior building fire alarm systems are covered by Section
22、 28 31 74.00 20 INTERIOR FIRE DETECTION AND ALARM SYSTEM and by Section 28 31 63.00 20, ANALOG ADDRESSABLE INTERIOR FIRE ALARM SYSTEM.*NOTE: Close coordination by the designer with the EFD/EFA Fire Protection Engineer, the Federal Fire Chief, and facility fire alarm maintenance personnel is absolute
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NAVYUFGS28313313202006EXTERIORFIREREPORTINGSYSTEMRADIOTYPE 射频 外部 火灾 报告 系统 PDF

链接地址:http://www.mydoc123.com/p-984832.html