NAVY UFGS-02 82 33 13 20-2011 REMOVAL CONTROL AND DISPOSAL OF PAINT WITH LEAD《含铅涂料的移除 控制和处理》.pdf
《NAVY UFGS-02 82 33 13 20-2011 REMOVAL CONTROL AND DISPOSAL OF PAINT WITH LEAD《含铅涂料的移除 控制和处理》.pdf》由会员分享,可在线阅读,更多相关《NAVY UFGS-02 82 33 13 20-2011 REMOVAL CONTROL AND DISPOSAL OF PAINT WITH LEAD《含铅涂料的移除 控制和处理》.pdf(26页珍藏版)》请在麦多课文档分享上搜索。
1、*USACE / NAVFAC / AFCESA / NASA UFGS-02 82 33.13 20 (August 2011)-Preparing Activity: NAVFAC SupersedingUFGS-02 82 33.13 20 (February 2010)UFGS-02 82 33.13 20 (April 2006)UFGS-13283 (February 2002) UNIFIED FACILITIES GUIDE SPECIFICATIONSReferences are in agreement with UMRL dated July 2011*SECTION T
2、ABLE OF CONTENTSDIVISION 02 - EXISTING CONDITIONSSECTION 02 82 33.13 20REMOVAL/CONTROL AND DISPOSAL OF PAINT WITH LEAD08/11PART 1 GENERAL1.1 REFERENCES1.2 DEFINITIONS1.2.1 Abatement1.2.2 Action Level1.2.3 Area Sampling1.2.4 Child Occupied Facility1.2.5 Competent Person (CP)1.2.6 Contaminated Room1.2
3、.7 Decontamination Shower Facility1.2.8 Deleading1.2.9 Eight-Hour Time Weighted Average (TWA)1.2.10 High Efficiency Particulate Air (HEPA) Filter Equipment1.2.11 Lead1.2.12 Lead-Based Paint (LBP)1.2.13 Lead-Based Paint Activities1.2.14 Lead-Based Paint Hazard (LBP Hazard)1.2.15 Paint with Lead (PWL)
4、1.2.16 Lead Control Area1.2.17 Lead Permissible Exposure Limit (PEL)1.2.18 Personal Sampling1.2.19 Physical Boundary1.2.20 Target Housing1.3 DESCRIPTION1.3.1 Description of Work1.3.2 Coordination with Other Work1.4 SUBMITTALS1.5 QUALITY ASSURANCE1.5.1 Qualifications1.5.1.1 Qualifications of CP1.5.1.
5、2 Training Certification1.5.1.3 Testing Laboratory1.5.1.4 Third Party Consultant QualificationsSECTION 02 82 33.13 20 Page 1Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-1.5.2 Requirements1.5.2.1 Competent Person (CP) Responsibilities1.5.2.2 Lead-B
6、ased Paint/Paint with Lead Removal/Control Plan (LBP/PWL R/CP)1.5.2.3 Occupational and Environmental Assessment Data Report1.5.2.4 Medical Examinations1.5.2.5 Training1.5.2.6 Respiratory Protection Program1.5.2.7 Hazard Communication Program1.5.2.8 Lead Waste Management1.5.2.9 Environmental, Safety
7、and Health Compliance1.5.3 Pre-Construction Conference1.6 EQUIPMENT1.6.1 Respirators1.6.2 Special Protective Clothing1.6.3 Rental Equipment Notification1.6.4 Vacuum Filters1.6.5 Equipment for Government Personnel1.7 PROJECT/SITE CONDITIONS1.7.1 Protection of Existing Work to RemainPART 2 PRODUCTSPAR
8、T 3 EXECUTION3.1 PREPARATION3.1.1 Protection3.1.1.1 Notification3.1.1.2 Boundary Requirements3.1.1.3 Furnishings3.1.1.4 Heating, Ventilating and Air Conditioning (HVAC) Systems3.1.1.5 Decontamination Shower Facility3.1.1.6 Eye Wash Station3.1.1.7 Mechanical Ventilation System3.1.1.8 Personnel Protec
9、tion3.2 ERECTION3.2.1 Lead Control Area Requirements3.3 APPLICATION3.3.1 Work Procedures3.3.2 Lead-Based Paint Removal/Control/Deleading3.3.2.1 Indoor Paint Removal3.3.2.2 Outdoor Paint Removal3.3.3 Personnel Exiting Procedures3.4 FIELD QUALITY CONTROL3.4.1 Tests3.4.1.1 Air and Wipe Sampling3.4.1.2
10、Air Sampling During Paint Removal Work3.4.1.3 Sampling After Paint Removal/Control3.4.1.4 Testing of Removed Paint and Used Abrasive3.5 CLEANING AND DISPOSAL3.5.1 Cleanup3.5.1.1 Clearance Certification3.5.2 Disposal3.5.2.1 Disposal Documentation3.5.3 Payment for Hazardous Waste- End of Section Table
11、 of Contents -SECTION 02 82 33.13 20 Page 2Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-*USACE / NAVFAC / AFCESA / NASA UFGS-02 82 33.13 20 (August 2011)-Preparing Activity: NAVFAC SupersedingUFGS-02 82 33.13 20 (February 2010)UFGS-02 82 33.13 20
12、(April 2006)UFGS-13283 (February 2002) UNIFIED FACILITIES GUIDE SPECIFICATIONSReferences are in agreement with UMRL dated July 2011*SECTION 02 82 33.13 20REMOVAL/CONTROL AND DISPOSAL OF PAINT WITH LEAD08/11*NOTE: This guide specification covers the requirements for for limiting occupational and envi
13、ronmental exposure to lead when removing/controlling lead-based paint or paint with lead (LBP/PWL).Adhere to UFC 1-300-02 Unified Facilities Guide Specifications (UFGS) Format Standard when editing this guide specification or preparing new project specification sections. Edit this guide specificatio
14、n for project specific requirements by adding, deleting, or revising text. For bracketed items, choose applicable items(s) or insert appropriate information.Remove information and requirements not required in respective project, whether or not brackets are present.Comments, suggestions and recommend
15、ed changes for this guide specification are welcome and should be submitted as a Criteria Change Request (CCR).*NOTE: This guide specification is intended for use in projects where LBP/PWL must be removed/controlled (including paint film stabilization) or lead-based paint hazards abated as defined b
16、y Public Law 102-550 Title X - Residential Lead-Based Paint Hazard Reduction Act of 1992. Local requirements may be substantially restrictive for the conduction of LBP or LBP hazard abatement projects.*NOTE: This guide specification should be used with all of the requirements of 40 CFR 745 (or state
17、/local requirements in states with authorized SECTION 02 82 33.13 20 Page 3Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-programs) for projects involving lead-based paint hazard abatement in target housing and child occupied facilities being transf
18、erred or resolving facility-related work due to an occupant child with an elevated blood lead. In these projects, it is required that the specification editor has appropriate training regarding lead-based paint activities. Certification as a project designer per 40 CFR 745 is required. *NOTE: Where
19、LBP/PWL is not specifically being removed/controlled as a hazard abatement action or deleading, use Section 02 83 13.00 20 LEAD IN CONSTRUCTION.*NOTE: The classification of the lead-based paint or paint with lead as hazardous waste must be performed in accordance with 40 CFR 261, and in the design p
20、hase of the project. This classification is prerequisite to the requirement of special handling, storage, and disposal according to Federal, state and local hazardous waste management regulations. *NOTE: When historic preservation work will remove LBP/PWL, refer to the Secretary of the Interiors Sta
21、ndards for the Treatment of Historic Properties and/or Brief 37, “Appropriate Methods for Reducing Lead-Paint Hazards in Historic Housing“ as appropriate. *NOTE: Projects involving housing improvement, maintenance, or repair are not considered a lead-based paint hazard abatement action even if the e
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NAVYUFGS02823313202011REMOVALCONTROLANDDISPOSALOFPAINTWITHLEAD 涂料 控制 处理 PDF

链接地址:http://www.mydoc123.com/p-984699.html