NAVY MIL-T-81990-1975 TEST SET COUNTERMEASURES AND CHAFF DISPENSER AN ALM-164《AN ALM-164对抗措施和干扰物投放器试验装置》.pdf
《NAVY MIL-T-81990-1975 TEST SET COUNTERMEASURES AND CHAFF DISPENSER AN ALM-164《AN ALM-164对抗措施和干扰物投放器试验装置》.pdf》由会员分享,可在线阅读,更多相关《NAVY MIL-T-81990-1975 TEST SET COUNTERMEASURES AND CHAFF DISPENSER AN ALM-164《AN ALM-164对抗措施和干扰物投放器试验装置》.pdf(10页珍藏版)》请在麦多课文档分享上搜索。
1、MIL-T-81770 58 7977706 0172622 T . -/ !. .i I il 8. , * I , i) -I / I .I -Y MILITARY SPECIFICATION MIL-T- 81490 (AS) 17 March 1975 TEST SET, COUNTERMEASURES AND CHAFF This specification has been approved by the Naval Air Systems Command, Department of the Navy. DISPENSER AN/ALM-164 1. SCOPE -. J.1 S
2、cope - The equipment covered by this specification shall This specification covers design, development and test be for operational checkout of the Dispensing Set, Countermeasures and Chaff AN/ALE-39. requirements for the equipment. The equipment shall be for organizational andintermediate use as def
3、ined for class 2 and 3 of MIL-T-21200. 12 Classification - The equipment covered by this specification shall consist of the following items: - Goodyear Aerospace Reference Drawing Number Nomenclature Paragraph 3100 304-001 Test Set AN/ALM-164 3.7.1 3100307-001 Cable Assy W-2X 3.3.2 3100307-002 Cable
4、 Assy W-5X 3.3.2 3100307-003 Cable Assy W-1 3.3.2 3100307-004 . Cable Assy W3 APPLICABLE DOCUMENTS 2.1 General - The following documents of the issue in effect on the date of invitation for bids or request for proposal, form a part of this specification to the extent specified herein, SPECI.FICATION
5、S . Military MIL-K-3926 MIL-Q-9858A Quality Program Requirements BlIL-E-17555 Electronic and Electrical Equipment and Associated Repair Parts, Preparation for Delivery of MIL-T-18303 Test Procedures; Preproduction, Acceptance, and Life for Aircraft Electronic Equipment, Formt for , MIL-N-18307 Nomen
6、clature and Nameplates for Aeronautical Elec- tronic and Associated Equipment MIL-T-21200 Equipment, General Specification for MIL-D-81694 Dispensing Set, Countermeasures and Chaff AN/ALE-39 Knob, Control (for use $irh Electronic Communications, and Allied Equipment) Test Equipment for Use with Elec
7、tronic and Electrical STANDARDS Military MIL-STD-129 Marking.for Shipment and Storage MIL-STD-130 MIL-STD-454 MIL-STD-461 Electromagnetic Interference Characteristics Require- MIL-STD-704 Electric Power Aircraft Characteristics and Utilization MIL-STD-794 Parts and Equipment Identification Marking o
8、f U .S. Military Property Standard General Requirements for Electronic Equipment ments or Equipment of DMWINGS Goodyear Aerospace Corporation Drawings 3100301-001 Schematic, AN/ALM-1.64 3100304-001 Test Set, Countermeasure Chaff Dispenser ANIALM-164 2.1.1 Availability of documents - (I.) Mien rcqucs
9、tlng spccificationn, standards, drawings, iitl pullfcnt.rii.r, reler tn both title and number. 2 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-Copies of this specification and applicable specifi- cations requiredby contractors in connection with sp
10、ecific procurement functions may be obtained upon application to the Commanding Officer, Naval Publica-. tions and Forms Center; 5801 Tabor Avenue, Philadelphia, Pennsylvania 19120. 3. REQUIREMENTS 3.1 (see 4). Testing - This specification makes provision for testing 3.2 Materials, parts, and proces
11、ses - The materials, parts, and processes shall be in accordance with MIL-T-21200, except as specified herein. 3.2.1 . Selection of parts, materials, and processes - Except as specified herein, MIL-T-21200 shall apply for the selection of parts, materials and processes. 3.2.2 Approval, of non-standa
12、rd parts and materials - Approval for the use of non-standard parts and materials shall be in accordance with MIL- T-21200. Pt. Mugu, Code 5233. Requests for approval shall be submitted to Naval Missile Center, 3.3 Dean and construction - The design and construction of the equipment shallbe in accor
13、dance with MIL-T-21200 except as modified herein. 3.3.1 Total weight - The total weight of the equipment, including cables, shall be a minimum consistent with good design and shall not exceed 45 pounds. 3.3.2 Cables and connectors - The equipment shall provide for the usc of cables and Connectors. I
14、nsofar as is practicable, all connectors on the front panel shall be mounted along the lower edge of the panel and in no case shall their location be such that th-e connecting cables will interfere with the operating controls. Cable assemblies shall be as depic- ted in Goodyear Aerospace drawings 32
15、00307-001, -002, -003, and -004. 3.3.2.1 Cabling - The test equipment cabiing shall be compatible with the equipment to be tested: It shall be the electrical equivalent of the cabling used in the nqrmal installation of the equipment being tested. .3.3.2.2 External connectors - External connectors sh
16、all provide for the following: 3 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-T-1770 58 W 7777706 0172625 5 W Reference Cannec tor - Designation Type Fun c t ion J-1 MS 3122 El 2-3P . 28V DC Input 5-2 - 5-5 M39012/21-0003 Programmer Pulse 5-6
17、MS3122E16-26PW Programmer Input 5-7, 5-8 MS3122E18-32P Disuenser Outsut Mon . . J-9 M39012/21-0003 Programm. Clock Freq. J-10 M39012/ 21-0003 Firing Pulse Monitor 3.3.3 Controls - Operating controls shall be in accordance with MIL-STD-454 Requirement 28. with MIL-K-3926. Controls shall be provided f
18、or: Knobs shall conform to MS 91528 in accordance u. Payload Selection b. Fire Comon Selection c. Circuit Selection 3.4 Reliability - The contractor shall conduct a reliability The program using MIL-STD-785 as a gu$de as described in this section. program plan shall be approved by the procuring acti
19、vity. No demonstration shall be required and reliability shall be verified by analysis. 3.4.1 Reliability Design Evaluation - A reliability prediction shall be made using MIL-STD-756 as a guide. each mode of test set operation. Predictions shall be made for 3.4.1.1 Failure Recurence Control - The co
20、ntractor shall implement a closed loop system for collecting, analyzing and recording failures that occur during in-plant acceptance testing and those that occur at install- ation sites or test sites prior to turnover to the procuring agency. The contractor failure reporting system shall include pro
21、visions to assure that effective corrective actions are taken on u timely basis and shall include follorup audits to review all open reports, analyses and correc- tive actions. Delinquent open report shall be reported to management for proper resolution. 3.4.1.2 Interference Control - As a design go
22、al the generation of electromagnetic interference by the equipment and the vulnerability of the equipment to electromagnetic interference shall be controlled within the limits of MIL-STD-461 (Notice i), for Class IC equipment. 3.4.2 Nomenclature and nameplates - Nomenclature assignment and nameplate
23、 approval for equipment identification shall be in accordance with MIL-N-18307. ,. 3.4.3 Service conditions - Service conditions (environmental) shall be in accordance with the following: Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-T-L970 58
24、m 9999906 0272626 7 m 3.4.3.1 Shock - As specified in MIL-T-21200 for equipment mounted in Transit and Combination Cases. 3.4.3.2 Vibration - The application of vibration shall be as speci- fied for Class 2 and 3 equipment in MIL-T-21200. 3.4.3.3 3.4.3.4 Humidity - As specified in MIL-T-21200. Salt
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NAVYMILT819901975TESTSETCOUNTERMEASURESANDCHAFFDISPENSERANALM164ANALM164 对抗 措施 干扰 投放 试验装置 PDF

链接地址:http://www.mydoc123.com/p-982889.html