1、Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-T-23588C 13 777770b 0303478 L MI-T23588C( OS) DMWINGS Naval Ordnance Systems Cormnand LD 620031 Shipping (Packing) Condition mg 1803636 Transducer, Pressure * PUBLICATIONS Naval Ordnance Systems Cor
2、mnand os 634i Miscellaneous General Ordnance De- sign Requirements (Copies of specifications, standards, drawings, and publications re- quested by the contractors in connection with specific procurement furictions should be obtained from the procuring activity or as directed by the con- tracting off
3、icer. ) 2.2 Other publications. The following documents form a part of this specification to the extent specified herein, Unless otherwise indicated, the issue in effect on date of invitation for bids or request for proposal shall apply. National Bureau of Standards Publication Handbook 128 Screw-Th
4、read Standaxds for Federal Services . (Application for coptes should be addressed to the Superintendent. of Documents, Goverment Binting Office, Washington, D. C. 20402. ) 3. REQUIFBMENTS 3.1 Description. The transducer is a pressure-sensitive device which produces a voltage output proportional to t
5、he external pressure applied to the un5t. The transducer incorporates a pressure-sensitive tube, to the outside of which are bonded resistive strain wire grids in a bridge network. Variations in pressure cause the grids to expand and stretch, changing the resistance. Therefore, each change in pressu
6、re will cause a change in voltage output. 3.2 General requirements * 3.2.1 Data required. No data is required by this specification (other than reports accompanying samples submi.f;ted for preproduction and periodic 2 Provided by IHSNot for ResaleNo reproduction or networking permitted without licen
7、se from IHS-,-,-MIL-T-235C 13 7797 3.3.2 Linearrity, Linearity is the rrraxirmun deviation of %he caibration curve from a straight line drawn between the no-pressure and full-scale pressure ou%puk, compressed as a percentage of the ful-scale output and measured OD increasing pressure only. 3 MIL-T-S
8、3588C( OS) production testing), or by applicable documents referenced in Section 2, unless specified in he contrack or order (see 6.2). 3.2.2 4 volts, 400 t: 12 Hertz (Hz). 3.4.3 Zero drift. Zero drift, due to the application of 8 k .4 volts, scale output at the 15-second period after application of
9、 voltage. After 15 seconds- and for a 5 minute period thereafter, the.zero drift shall not exceed 0.1 percent of full-scale output and shall continue to drop there- after until thermal equilibrium is reached, when tested as snecificed in 4.5.4.2. be 1.95 microvolts plus 15 percent minus LO percent p
10、er volt input per psig. 4O 1- 12 Hz-to terminals 3.-and 4, shall not exceed 0.25 percent of full- 3.404 Output voltage. The output voltage of the pressure cell shall 3.4.5 Zero error. The zero error shall be less than 5 percent of full- scale output. 3.4.6 Maximum nonlinearity. For increasing pressu
11、re, the maximum non- linearity shall be less than plus or minus 0.25 percent of flzll-scale out- 3.4.7 Hysteresis. The difference in outputs obtained by increasing the pressure from O to 500 psig and decreasing the pressure from 500 to O psig shall be within 0.25 percent of full-scale output. 3.4.8
12、Zero return. The zero return after a one minute pressure cycle chasacteris- tics of this specification af%er being tested as in 4.4.1.1. 3.5.1.2 Vibration, operating. The transducer shall show no damage and shali meet all the performance requirements and product characteristics of this specification
13、 during and after %he test specified in 4.4.1.2. 3.5.2 Temperature and humidity 3+5.2.1 High temperature and humidity, nonoperating. The transducer shall show no damage an shall meet all the performance requirements and product characteristics of this specification after being tested as in 4+4.2.1.
14、3.5.2.2 High temperature, operating. The transducer shall be capable of meting all the performance reqerements of this specification while undergaing the test specified in 4.4.2.2. 5 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-T-23588C (OS) *
15、 3.5.2.3 Low temperature, nonoperating. The transducer shall meet all the performance requirements and product characteristics of this specifi- cation after being tested as in 4.4.2.3. * 3.5.2.4 Low temperature, operating. The transducer shall be capable of meeting all the performance requirements o
16、f this specification while undergoing the test specified in 4.4.2.4. 3.5.2.5 Thermal effect on zero shift. zero shift for thermal equilibrium within the cell shall be less than 0.01 percent of fullscale output per degree Fahrenheit (F) throughout a temperature range of plus 28 degrees to plus 130 de
17、grees F. With input voltage at 8 volts, 3.5.2.6 Thermal effect on sensitivity shift. thermal equilibrium within the cell shall be less than 0.01 percent of Sensitivity shift for full-scale output per degree F throughout a temperature range of plus 28 degrees to plus 130 degrees F. 3.5.2.7 Thermal sh
18、ock. Wetting of the pressure sensing element with water at a differential temperature of 40 degrees F followed by immersion of the transducer shall not change the O psig pressure output by more than 4 percent of full-scale output within immersion. After one minute of immersion, the change shall not
19、exceed 0.5 percent of full scale output. a period of one minute after * 3.5.3 Fungus. The transducer shall meet all performance requirements of this specification after being tested in accordance with 4.4.3. 3.5:;4 Pressure-voltage sensitivity. The maximum time for the output voltage to reach 63 per
20、cent of the final output for any step pressure input, within the range of the transducer, shall be 2.4 milliseconds. 3.5.5 Zero output stability. The transducer output at O psig, with zero unbalance corrected for minimum, shall not change by more than 0.05 percent of full-scale output when the sourc
21、e voltage is varied over the range of 7.76 to 8.24 volts. 3.5.6 Phase relationships. 3.5.6.1 At O psig, the portion of the output voltage that is 90 degrees to the supply voltage shall not exceed plus ox minus 1.5 microvolts output per volt input at 400 Hz. 6 Provided by IHSNot for ResaleNo reproduc
22、tion or networking permitted without license from IHS-,-,-MIL-T-235C 13 977790b 0303503 I m _ - _-_ - - - - MIL-T-23588C( OS) 3.5.6.2 The phase change in output voltage for a given pressure stin- ULus shall not exceed an angle of plus or minus 0.1 degree with respect to the supply voltage. 3.5.6.3 M
23、hen pressure is applied, output terminal1 shall have the same polarity as input terminai 4. 3.6 CemuE. Prior to and after final assembly, au parts, compon- ents, and the assembly shall be thoroughly cleaned of loose, spattered, or excess soler, metal chips, and other foreign natter. sharp edges as w
24、ell as rosin flash shall be removed. Burrs and 3.7 torimanship. The transducer, including all parts and accessories, shall be constructed and finished in a manner to ensure compliance with all requirements of this specification. pata to neatness and thoroughness of soldering, wiring, impregnation of
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NAVYMILT23588C1974TRANSDUCERPRESSURE 压力传感器 PDF

链接地址:http://www.mydoc123.com/p-982627.html