NAVY MIL-R-82441 A-1974 REGULATOR ASSEMBLY CARBON DIOXIDE PRESSURE《二氧化碳调压器》.pdf
《NAVY MIL-R-82441 A-1974 REGULATOR ASSEMBLY CARBON DIOXIDE PRESSURE《二氧化碳调压器》.pdf》由会员分享,可在线阅读,更多相关《NAVY MIL-R-82441 A-1974 REGULATOR ASSEMBLY CARBON DIOXIDE PRESSURE《二氧化碳调压器》.pdf(21页珍藏版)》请在麦多课文档分享上搜索。
1、r a3 MIL-R-6244lA 13 999990b 04313Lt7 b MIL-R-82441A (OS) 9 October 1974 Superseding MIL-R-82441 (OS) 10 May 1966 MILITARY SPEC I FICATI ON REGULATOR ASSEMBLY, CARBON DIOXIDE PRESSURE This Specification is approved for use by all Departments And Agencies of the Department of Defense. 1. SCOPE 1.1 Sc
2、ope. This specification covers one type of carbon dioxide pressure regulator assembly referenced herein as the “regulatortt. 2. APPLICABLE DOCUMENTS * 2.1 Applicable documents. The following documents of the issue in effect on date of invitation for bids or request for proposal form a part of this s
3、pecification to the extent specified herein. SPECIFICATIONS Military MIL-P-116 MIL-F-18866 MIL-S-22473 STANDARDS Military MIL-STD-105 MIL-STD-129 Preservation-Packaging, Methods of Fittings, Hydraulic Tube, Flared, 37- Degree And Flareless; Steel Sealing, Locking , .and Retaining Compounds; Single-C
4、omponent Sampling Procedures and Tables for Inspection by Attributes Marking for Shipment and Storage IFSC 13551 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-R-82V41A 13 777770b CIL131348 8 - z MIL-R-82441A(OS) MS-19060 Ms-20995 Ball, Bearing,
5、 Ferrous,Corrosion Resisting Steel Wire, Safety or Lock DRAWINGS Naval Ordnance Sys terns Command DL- 1330653 Regulator Assembly LM- 25 2 6 7 9 9 Test Assembly, Regulator (Copies of specifications, standards, drawings, and publications required by contractors in connection with specific procurement
6、functions should be obtained from the procuring activity or as directed by the contracting officer.) * 2.2 Other publications. The following documents form a part of this speci- fication to the extent specified herein. Unless otherwise indicated, the issues in effect on date-of invitation for bids o
7、r request for proposal shall apply: AEROSPACE INDUSTRIES ASSOCIATION OF AMERICA, INC. NAS 617 Packing, Preformed, Straight Thread Tube BOSS, Synthetic Lubricant Resistant c (Application for copies should be addressed to Aerospace Industries Association of America, Inc. , 1725 DeSales St. N.W. , Wash
8、ington, D.C. 20036) NATIONAL MOTOR FREIGHT TRAFFIC ASSOCIATION, INC. AGENT National Motor Freight Classification (Application for copies should be addressed to American Trucking Associations, ATTN: Tariff Order Section, 1616 P Street, N.W. , Washington; D.C. 20036.) UNIFORM CLASSIFICATION COMMITTEE
9、AGENT Uniform Freight Classification (Application for copies should be addressed to the Uniform Classification Committee, Room 1106, 222 South Riverside Plaza, Chicago, Illinois 60606.) (Technical soc!,ety. and techni.ca1 association specifications and standards are generally wa?.lable for reference
10、 from libraries, among techka1 groups and using Federal Agencies). They are also distributed 2 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-F MIL-R-2491A-L3 = 9999906 0931349 T I 3. REQUIREMENTS 3.1 Classification of requirements. The requirements
11、 for the regulator are classified herein as follows: REQUIREMENT PARAGRAPH General Requirements Performance Requirements Environmental Requirements Operational Service Life and Product Characteristics 3.2 General reauirements 3.2 3.3 3.4 3.5 3.2.1 Preproduction sample. Unless otherwise specified in
12、the contract or order (see 6.2), a preproductton sample of the regulator is required and shall be manufactured using the methods and procedures proposed for production. purpose of determining that, prior to starting production, the contractors production methods are capable of yielding items that co
13、mply with the technical requirements of the contract (see 4.3.1). The sample shall be tested as specified in Section 4 for the * 3.2.2 Materials. Unless otherwise specified in the contract or order (see 6.21, all materials and treatments of materials and parts used in the manufacture of the regulato
14、r shall.be in accordance with applicable documents listed on DL1330653. 3.2.3 Weight. 3.2.4 Definitions. See 6.3 for definitions of terms. 3.3 Performance requirements and product-characteristics. Unless specified otherwise (see 6.21, the regulators shall satisfy the follow- ing performance requirem
15、ents when tested as specified in Section 4: The weight of the regulator shall not exceed one pound. * 3.3.1. Pressure regulation. The regulator, connected to the Regulator Test Assembly, LM 2526799, shall maintain an outlet pressure between 80 and 130 pounds per square inch, gage (psig) with an inle
16、t pressure from 250 to 2700 psig, with valve “A“ in small orifice position (See Figure IC), * 3.3.2. m. The regulator, connected to theRegulator Test Assembly, LM 2526799, with an applied inlet pressure of 250 I10 psig shall maintain an outlet pressure greater than 40 psig with valve Atii in large o
17、rifice position (See Figure 13. 3 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-R-82441A 33 W 77777Ob 0433350 b W- MIL-R-8244lA(OS) 3.3.3 Relief valve. The relief valve shall have a cracking pressure I of 200 f25 psig and a reset pressure of 14
18、0 psig minimum. At 140 psig, the valve shall have a maximum leakage rate of 0.5 cubic centimetres per minute %t Standard Test Conditions (cm3/min-Std). 3.3.4 Case leakage. The regulator assembly, in the operating condi- tion, shall show no sign of leakage when tested in accordance with 4.5.3 Ccl . .
19、k 3.3.5 Check valve. The check valve shall have a cracking pressure of 4 +2 psig. nal or reverse flow leakage as detectable by a bubble test. there shall be no reverse flow or external leakage when a pressure of 12 +2 inches of water is applied to the outlet of the check valve. With 300 +25 psig at
20、the outlet there shall be no exter- Similarly, 3.4 Environmental requirements. Unless otherwise specified (see 6.21, the regulator shall be capable of conforming to the performance require- ments and product characteristics of thrs specification after exposure to the following environmental conditio
21、ns (Ready, operating, and non- operating are defined in 6.31 3.4.1 Vibration, ready condition. The regulator, while in the ready condition and mounted as shown in figure 2, shall be capable of meeting the performance requirements of 3.3 after being subjected to the vibra- tions specified in Table I.
22、 minutes each in the longitudinal axis and in the two mutually perpendi- cular transverse axes (see figure 21, at various temperatures within the range of -43 to 60C (-45 to 14O0F (vibration is defined in 6.3.4) (see 4.4.4.2). The regulator shall be vibrated for 180 3.4.2 Acceleration, ready conditi
23、on. The regulator, in the ready con- dition and mounted as shown in Figure 2, shall be capable of meeting the performance requirements of this specification after being subjected to the accelerations specified in Table II. 6.3.5). (Acceleration is defined in TABLE I Vibration Schedule Double Amplitu
24、de (in. +lo%) Minimum -. 0.2 - O. 036 - Acceleration (gs +.lo%) Minimum Frequency (Hz 5 - 22 22 - 40 40 - 74 74 - 500 4 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-R-8244LA 13 W 9999906 0431351 W % Acceleration Direction (See Figure 2) Magnit
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NAVYMILR82441A1974REGULATORASSEMBLYCARBONDIOXIDEPRESSURE 二氧化碳 调压器 PDF

链接地址:http://www.mydoc123.com/p-981414.html