NAVY MIL-PRF-32152-2005 CLOSURE HVAC BUTTERFLY TYPE SHIPBOARD SERVICE《船用蝶型HVAC闭合》.pdf
《NAVY MIL-PRF-32152-2005 CLOSURE HVAC BUTTERFLY TYPE SHIPBOARD SERVICE《船用蝶型HVAC闭合》.pdf》由会员分享,可在线阅读,更多相关《NAVY MIL-PRF-32152-2005 CLOSURE HVAC BUTTERFLY TYPE SHIPBOARD SERVICE《船用蝶型HVAC闭合》.pdf(21页珍藏版)》请在麦多课文档分享上搜索。
1、Comments, suggestions, or questions on this document should be addressed to: Commander, Naval Sea Systems Command, ATTN: SEA 05Q, 1333 Isaac Hull Avenue, SE, Stop 5160, Washington Navy Yard DC 20376-5160 or emailed to commandstandardsnavsea.navy.mil, with the subject line “Document Comment”. Since c
2、ontact information can change, you may want to verify the currency of this address information using the ASSIST Online database at http:/assist.daps.dla.mil. AMSC N/A FSC 4820 INCH-POUND MIL-PRF-32152(SH) 11 April 2005 PERFORMANCE SPECIFICATION CLOSURE, HVAC, BUTTERFLY TYPE, SHIPBOARD SERVICE This s
3、pecification is approved for use by the Naval Sea Systems Command and is available for use by all Departments and Agencies of the Department of Defense. 1. SCOPE 1.1 Scope. This specification describes watertight, fire resistant butterfly closures used in heating ventilation and air conditioning (HV
4、AC) systems onboard Naval surface ships. 1.2 Classification. Closures are of the following styles, types, sizes, and structures as specified (see 6.2): 1.2.1 Styles. The styles of butterfly closures are as follows: Style R - Round Style K - Flat Oval 1.2.2 Types. The types of butterfly closures are
5、as follows: Type I - Handle operated Type II - Handwheel operated Type III - Motor operated 1.2.3 Sizes. The sizes of butterfly closures are as follows: Style R nominal size in inches Style K nominal size in inches 2 12 31 (7x3) 3 14 32 (8x4) 3 16 33 (9x5) 4 18 34 (11x6) 5 20 35 (13x7) 6 24 36 (16x8
6、) 8 30 37 (20x9) 10 36 38 (24x10) 39 (24x10) 40 (30x16) 41 (30x20) Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-32152(SH) 2 1.2.4 Structure. The structure code of butterfly closures is as follows: Nonmagnetic structure (NM) or the option t
7、o be not applicable (NA). 1.3 Part or identifying number (PIN). PINs to be used for watertight, fire resistant butterfly closures acquired to this specification are created as follows: M 32152 - X X XXX XX Prefix for Military Specification Specification Number Style (see code below) Type (see code b
8、elow) Size (see code below) Structure (see code below) Style Code Type Code Size Code Structure Code Style Code Type Code Size Code 1/Structure Code R R I 1 Style R only Nonmagnetic NM K K II 2 2 02H Not applicable NA III 3 3 03W 3 03H 4 04W 5 05W 6 06W 8 08W 10 10W 12 12W 14 14W 16 16W 18 18W 20 20
9、W 24 24W 30 30W 36 36W Style K only 31 (7x3) 31W 32 (8x4) 32W 33 (9x5) 33W 34 (11x6) 34W 35 (13x7) 35W 36 (16x8) 36W 37 (20x9) 37W 38 (24x10) 38W 39 (24x10) 39W 40 (30x16) 40W 41 (30x20) 41W NOTE: 1/“W” denotes a whole number; “H” denotes the fraction “”. Examples: M32152-R202HNM M32152-K338WNA Prov
10、ided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-32152(SH) 3 2. APPLICABLE DOCUMENTS 2.1 General. The documents listed in this section are specified in sections 3, 4, or 5 of this specification. This section does not include documents cited in oth
11、er sections of this specification or recommended for additional information or as examples. While every effort has been made to ensure the completeness of this list, document users are cautioned that they must meet all specified requirements of documents cited in sections 3, 4, or 5 of this specific
12、ation, whether or not they are listed. 2.2 Government documents. 2.2.1 Specifications, standards, and handbooks. The following specifications, standards, and handbooks form a part of this document to the extent specified herein. Unless otherwise specified, the issues of these documents are those cit
13、ed in the solicitation or contract. DEPARTMENT OF DEFENSE SPECIFICATIONS DOD-V-24657 - Valve Actuator, Direct Coupled, Gear Driven Electrically Powered for Naval Shipboard Propulsion and Auxiliary Systems (Metric) MIL-S-901 - Shock Tests, H.I. (High-Impact) Shipboard Machinery, Equipment, and System
14、s, Requirements For DEPARTMENT OF DEFENSE STANDARDS MIL-STD-167-1 - Mechanical Vibrations of Shipboard Equipment (Type IEnvironmental and Type II Internally Excited) MIL-STD-798 - Nondestructive Testing, Welding, Quality Control, Material Control and Identification and HI-Shock Test Requirements for
15、 Piping System Components for Naval Shipboard Use MIL-STD-889 - Dissimilar Metals MIL-STD-1399-300 - Interface Standard for Shipboard Systems, Electric Power, Alternating Current (Metric) MIL-STD-2142 - Magnetic Silencing Characteristics, Measurement Of (Metric) (Copies of these documents are availa
16、ble online at http:/assist.daps.dla.mil/quicksearch/ or http:/assist.daps.dla.mil or from the Standardization Document Order Desk, 700 Robbins Avenue, Building 4D, Philadelphia, PA 19111-5094.) 2.2.2 Other Government documents, drawings, and publications. The following other Government documents, dr
17、awings, and publications form a part of this document to the extent specified herein. Unless otherwise specified, the issues of these documents are those cited in the solicitation or contract. NAVSEA TECHNICAL PUBLICATION S9074-AR-GIB-010/278 - Requirements for Fabrication, Welding and Inspection, C
18、asting Inspection and Repair for Machinery, Piping and Pressure Vessels (Copies of this document are available from the Naval Inventory Control Point, 700 Robbins Avenue, Attn: Code 0862 (Cash Sale), Philadelphia, PA 19111 or online at www.nll.navsup.navy.mil.) Provided by IHSNot for ResaleNo reprod
19、uction or networking permitted without license from IHS-,-,-MIL-PRF-32152(SH) 4 NAVSEA DRAWINGS NAVSEA 803-1385620 - Handwheels for Valves NAVSEA 804-1749102 - Ventilation Closure Watertight and Fire-Resistant Model “R” Round NAVSEA 804-1749103 - Ventilation Closure Watertight and Fire Resistant Mod
20、el “K” Flat Oval (Copies of these drawings are available from the Naval Inventory Control Point, 700 Robbins Avenue, Attn: Code 0862 (Cash Sale), Philadelphia, PA 19111 or online at www.nll.navsup.navy.mil.) 2.3 Non-Government publications. The following documents form a part of this document to the
21、 extent specified herein. Unless otherwise specified, the issues of these documents are those cited in the solicitation or contract. AIR MOVEMENT AND CONTROL ASSOCIATION (AMCA) INTERNATIONAL, INC. AMCA 500 - Test Methods for Louvers, Dampers, and Shutters (DoD adopted) (Copies of this document are a
22、vailable from the Air Movement and Control Association, Inc., 30 West University Drive, Arlington Heights, IL 60004 or online at www.amca.org.) AMERICAN WELDING SOCIETY (AWS) B2.1 - Welding Procedure and Performance Qualifications, Standard for (DoD adopted) B2.2 - Brazing Procedure and Performance
23、Qualification, Standard for (DoD adopted) (Copies of these documents are available from the American Welding Society, 550 NW LeJeune Road, Miami, FL 33216 or online at www.aws.org.) ASME INTERNATIONAL ASME B1.1 - Unified Inch Screw Threads, UN and UNR Thread Form (DoD adopted) ASME B18.2.1 - Square
24、and Hex Bolts and Screws, Inch Series (DoD adopted) (Copies of these documents are available from ASME International, 22 Law Drive, P.O. Box 2900, Fairfield, NJ 07007-2900 or online at www.asme.org.) ASTM INTERNATIONAL ASTM F1166 - Standard Practice for Human Engineering Design for Marine Systems, E
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NAVYMILPRF321522005CLOSUREHVACBUTTERFLYTYPESHIPBOARDSERVICE 船用蝶型 HVAC 闭合 PDF

链接地址:http://www.mydoc123.com/p-981000.html