1、. 3 MIL-H-24936 1 July 1987 MILITARY SPECIFICATION HOOD, ANTI-FLASH, FLAME RESISTANT This specification is approved for use by all Departments and Agencies of the Department of .Defense. 1. SCOPE 1.1 Scope. This specification covers the requirements for one type and size knitted 80% PFR rayon/ZO%.PB
2、I hood. 2 APPLICABLE DOCUMENTS 2.1. Government documents. 2.1.1 Specifications, standards, and handbooks. The following specifications, standards , and handbooks form a part of this specification to the extent specified .herein. Unless otherwise specified, the issues of these documents shall be thos
3、e listed in the issue of the Department of Defense Index of Specifications and. Standards (DODISS) and supplement thereto, cited in the solicitation. -1 SPEC IF ICAT IONS FEDERAL . . . NN-P -7 1 DDD-L-20 - PPP-B-6 36 d Pallet , Material Handling, Wood Stringer, Label; for Clothing, Equipage, and Ten
4、tage (General Boxes, Shipping, Fiberboard Construction, 2 Way and 4 Way (Partial) Us e) Beneficial comments (recommendations, additions, deletions) and any pertinent data which may be of use in-improving this document should be addressed to: Officer in Charge, Navy Clothing and Textile Research Faci
5、lity, 21 Strathmore Road, Natick, MA 01760-2490 by using the self-addressed Standardization Document Improvement Proposal (DD Form 1426) appearing at the end of this document or by letter. AMSC N/A FSC 8415 DISTRIBUTION STATEMENT A. Approved for public release; distribution is unlimited. t 7 THIS DO
6、CUMENT CONTAINS /? PAGES Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-H-24936 MILITARY MIL-P-150 11 - Pallet, Material Handling, Wood, Post Construction, MIL-T-83193 - Thread, Aramid, Spun Staple 4 Way Entry STANDARDS FEDERAL FED-STD-191 - Tex
7、tile Test Methods FED-STD-751 - Stitches, Seams, and Stitchings MIL I TARY MIL-STD-10 5 - Sampling Procedures and Tables for Inspection by MIL-STD-129. . MIL-STD-147 - Palletized Unit Loads Attributes - Marking For Shipment and Storage (Copies of specifications, standards drawings, .and publications
8、 required by contractors in connection with specific procurement functions should be obtained from the procuring activity or as directed by the contracting officer .) 2.1.2 Other Government documents, drawings, and publications. The following other Government documents, drawings, and publications fo
9、rm a part of this specification to the extent specified herein. Unless otherwise specified, the issues shall be those in effect on the date of the solicitation. LAWS .AND REGULATIONS US POSTAL SERVICE MANUAL (Copies of the manual may be obtained from the Superintendent of Documents, US Government Pr
10、inting Office, Washington, DC 20420). 2.2 Other publications. The following document(s) form a part of this specification to the extent specified herein. Unless otherwise specified, the issues of the documents which are DOD adopted shali be those listed in the issue of the DODISS specified in the so
11、licitation. Unless otherwise specified, the issues of documents not listed in the DODISS shall be the issue of the nongovernment documents which is current on the date of the , solicitation. . i NATIONAL MOTOR FREIGHT TRAFFIC ASSOCIATION, INC., AGENT Nat i onal Mo tor Freight C1 asci f i cat i on (A
12、pplications for copies should be addressed to the American Trucking Association, ATTN: Traffic Department, 1616 P Street, N.W., Washington, DC 20036). 2 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-i 2.3 Order of precedence. In the event of a conf
13、lict between the text of this specification and the references cited herein, the text of this specification shall take precedence. Nothing in this specification however, shall supersede applicable laws and regulations unless a specific exemption has been obtained. MIL-H-2473b 84 W 777770b 0384877 b
14、W MIL-H-24936 UNIFORM CLASSIFICATION COMMITTEE, AGENT Uniform Freight Classification (Applications for copies should be addressed to the Uniform Classification Committee, Room 1106, 222 South Riverside Plaza, Chicago, Illinois 60606). 3. REQUIREMENTS 3.1 Guide sample. Samples, when furnished, are so
15、lely for guidance and information to the contractor (see 6.3). Variations from this Specification may appear in the sample in which case this specification shall govern. 3.2 First article. When specified, the contractor chal-1 furnish sample unit(s) for first article inspection and approval (see 4.3
16、 and 6.2). 3.3 Material. 3.3.1 Basic material. The basic material used in the hood shall be a 1x1 rib knit of 80% PFR rayon and 20% PBI blended yarn, when tested as specified in 4.41. . 3.3.1.1 Rayon. The PFR rayon is manufactured by metering water-insoluble poly (n-propoxyphosphazene) into viscose
17、solution from which rayon fibers are spun. The fibers contain the flame retardant which is highly dispersed in a matrix of cellulose. The fiber shall be a blend of 50 percent 1-1/2 denier, 2 inch staple, and 50 percent 3 denier, 2 inch staple, when tested as specified in 4.4.1. 3.3.1.2 PBI. The fibe
18、r shall be 1-1/2 denier, 2 inch staple, when tested as specified in 4.4.1. 3.3.1.3 Color. The color shall be natural. 3.3.1.4 Nonfibrous material. The cloth shall contain no more than 1.0 percent starch and protein content including chlorof orm-soluble and water-soluble material when tested as speci
19、fied in 4.4.1. 3 . Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-H-ZLI73b 8i.I W 777770b 038Lt700 7 W a MIL-H-24936 E e 3.3.1,5 Physical requirements. The finished cloth shall conform to the physical requirements shown in Table I when tested as
20、 specified in 4.4.1. TABLE I. Physical requirements Characteristics Minimum Maximum Weight, oz/yd2 (g/m 2 ) Thickness, inches (2.54 cm) Wales/Courses per inch (2.54 cm) Wal es Cour ses Burst strength, lbs (N) Flame resistance, Initially and after 25 launderings: After flame time, seconds After glow
21、time, seconds Char length, inches (2.54 cm) 5.7( 193.2) 0.035 21 28 - 50 (222.5) 6.5 (220.4) 0.05 2 5 5 3.3.2 Thread. The thread for seaming and stitching the hood shall be aramid, spun staple, ticket no. 4.5, 3-ply, conforming to ML-T-83193. The color of the thread shall be natural. 3,3.3 Cotton el
22、astic webbing. The unblached elastic cotton webbing shall conform to the requirements in Table II (see 6.4), when tested as specified in 4.4.1. TABLE II. Webbing properties Width Thi c kne s s Ounces per linear yard Elongation ( i nches 1 (inches) . (inches) 1/4 - + 1/32 .016-.046 0.083 (+ - 0.02) 3
23、.5 (+ - 0.5) 3.3.4 Binding. The binding for the face opening of the hood and the bottom edge, of the yoke shall be basic material as specified in 3.3.1. The binding shall be. cut 1-i/4 inch wide, at a 5 degree crosscut pattern in continuous roll lengths. The finished width of the binding shall be 1/
24、2 (+ - 1/16) inch. 4 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-b MIL-H-24936 84 W 9999706 0384901 O W - MIL-H-24936 3.3.5 Label. Each finished hood shall have a combination identification and warning label conforming to type V, class 15, of DDD
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NAVYMILH249361987HOODANTIFLASHFLAMERESISTANT 防火 头盔 PDF

链接地址:http://www.mydoc123.com/p-979495.html