《NAVY MIL-H-22663-1960 HEATERS SPACE ELECTRIC BLOWER RADIANT AND TURRET (NAVAL SHIPBOARD)《带电空间加热器 鼓风机 (电炉或煤气炉的)白炽部分和转台(海军军舰用途)》.pdf》由会员分享,可在线阅读,更多相关《NAVY MIL-H-22663-1960 HEATERS SPACE ELECTRIC BLOWER RADIANT AND TURRET (NAVAL SHIPBOARD)《带电空间加热器 鼓风机 (电炉或煤气炉的)白炽部分和转台(海军军舰用途)》.pdf(10页珍藏版)》请在麦多课文档分享上搜索。
1、MIL-H-22663 - 45 777990b 0453738 8 - - - - - 9 - -_ MIL-H- 22663( SHIPS) - - . 15 November 1960 SUPERSEDING 15 November 1957 29 April 1957 - -. - MIL- H- 194C( SHI PS) MIL-H- 19548A(SHIPS) =. -.=*- %- -2 - - -a=-=- - MILITARY SPECIFICATION HEATERS, SPACE, ELECTRTC: BLOWER, RADIANT AND TURRET (NAVAL
2、SHIPBOARD) 1. SCOPE 1.1 Scope. - This specification covers electric space heaters; blower, radiant and turret, for Naval shipboard use. 1.2 Classification. - Electric heaters shall be furnished in the following types and ratings, as speci- fied (see 6.2). The letters “NM“ following the type . design
3、ation (for example type D-NM) denote heaters of special nonmagnetic construction. Type B - Blower (2 heat increments-wattage shown applies to “high“ heat) Ratings: 2000 watts, 250 (175-355) volts, d.c. 4000 watts, 250 (175-355) volts, d.c. 2000 watts, 500 (355-710) volts, d.c. 4000 watts, 500 (355-7
4、10) volts, d.c. 2000 watts, 440 volts, 3 phase, 60 cycles, 4000 watts, 440 volts, 3 phase, 60 cycles, a.c. a.c. Type D - Radiant (single heat) Class 1 - Bulkhead mounted Ratings: 1000 watts, 115 volts, d.c. 1000 watts, 230 volts, d.c. 1000 watts, 440 volts, 3 phase, 60 cycles, a.c. Class 2 - Portabl
5、e Rating: 1000 watts, 115 volts d.c. or single phase, 60 cycle a.c. Type T - Turret (single heat) Ratings; 500 watts, 115 volts d.c. or single phase, 60 cycle a.c. 1000 watts, 115 volts d.c. or single phase, 500 watts, 440 volts, single phase, 60 1000 watts, 440 volts, single phase, 60 60 cycle a. c
6、. cycle a.c. cycle a.c. 2. APPLICABLE DOCUMENTS 2.1 The following specifications and standard, of the issue in effect on date of invitation for bids, form a part of this specification to the extent specified herein: SPECIFICATIONS MILITARY MIL-E-917 - Electric Power Equipment, Basic Requirements for
7、 (Naval Shipboard Use) MIL-D-963 - Drawings, Production, Pro- cedure for Procurement of MIL-B-3743 - Brushes, Electrical Con- tact; and Carbon Stock, Electrical Contact Brush MIL-H-22577 - Heating Elements, Elec- trical; Cartridge, Strip and Tubular Type Equipment and Associated Repair Parts, Prepar
8、ation for Delivery of MIL-E-17555 - Electronic and Electrical STANDARDS MILITARY MIL-STD-105 - Sampling Procedures and Tables for inspection by Attributes. (Copies of specifications, standards, drawings, and publications required by contractors in con- nection with specific procurement functions sho
9、uld be obtained from the procuring activity or as di- rected by the contracting officer .) Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-H-22bb3 45 MIL-H-22663( SHIPS) 999990b 0453939 T W 2.2 Other publications: - The following documents form a
10、 part of this specification to the extent specified herein. Unless otherwise indicated, the issue in effect on date of invitation for bids shall apply. AMERICAN STANDARDS ASSOCIATION, INC . Standard C33.1-1957 - Flexible Cord add Fix- ture Wire, Safety Standard for Standard C73a-1953 - Grounding-Typ
11、e Attach- ment Plug Caps and Receptacles and 3-Wire 30-ampere 250 volt Cap and Receptacle (Application for copies should be addressed to the American Standards Association, Inc . , 70 East 45th St., New York 17, N. Y.) 3. REQUIREMENTS 3.1 Material. - 3.1.1 General requirements. - All parts used in t
12、he construction of space heaters shall be the lightest possi- ble material consistent with good design and ruggedness of the assembled unit. The heaters shall have no flimsy or closely proportioned parts, and they shall be able to operate satisfactorily for a long life under normal ship- board condi
13、tions. 3.1.2 Material not specified hereinafter shall be selected on the basis of meeting the performance re- quirements of the specification at minimum cost. 3.1.3 Aluminum. - Aluminum, where used, shall be a type alloy that resists corrosion from sait water. not be placed in direct contact with co
14、pper or copper bearing alloys. 3.1.5 Nonmagnetic materiais. - Heaters of special nonmagnetic construction (see 1.2) shall be constructed entirely of nonmagnetic material unless other material is specifically approved by the bureau or agency con- cerned. Steel, when used, shall be of a nonmagnetic ty
15、pe. Nonmagnetic material is defined as material which has a magnetic permeability of less than 2. O after fabrication. 3.1.4 Dissimilar metals. - Aluminum alloys shall 3.1.6 Plastic material. - Plastic material shall be as required by Specification MC-E-917. 3.1.7 Insulation. - Heat insulating mater
16、ials shall be highly resistant to heat and moisture absorption. The materials shall be nonfragile and shall be suitably supported. 3.2 Air circulation. - Transfer of heated air from the heater to the ships space being heated shall be accomplished in an efficient manner. Baffles, deflectors and refle
17、ctors may be used to aid in the transfer of heat. 3.3 Load balance. - Heaters for operation on a 440 volt, 3 phase, 60 cycle, a.c. power source shall have three or a multiple of three heating elements of equal wattage connected to provide a balanced load on each phase. 3.4 Connectig-boo- Heaters sha
18、ll be pro- vided with a connection box or its equivalent, totally enclosed and separated from the heating element section. The box shall not project from the heater outline. Access to the box shall be obtained by removing only the box cover and not a large section of the heater enclosing case. The c
19、onnection box shall provide a means for connec- tion of external leads, either a terminal board or a convenient arrangement of heating element ter- minals so that a direct connection can be made. The external leads shall not enter the connection box through the cover. Except for portable heaters (ty
20、pe D, class 2) that are furnished with a cord and plug, the connection box shall contain a hole or knockout plugs of a size to accomodate the cable clamp furnished with the heater. 3.5 Cable clamps. - A cable clamp shall be provided for securing the cord or supply cable of all heaters, both portable
21、 and permanently con- nected. The clamp shall be capable of securing cable having an outside diameter of 1/4 inch to 5/8 inch. Where knockout plugs are provided, the clamp shall be furnished separately, attached with cord or wire to the heater. 3.6 Connections (within heater). - Connections within t
22、he heater shall be made with metal connect- ing strips or wire suitable for the surrounding temperature. Where the terminal temperature is 400F or less, wire shall be silicone rubber in- sulated, tinned copper conductor having an outer covering of giass braid. Where the terminal tem- perature exceed
23、s 400F) wire shall be nickel con- ductor with heavy asbestos insulation. All connec- tions shall be made with nuts and lockwashers. 3.7 Creepage ._ and clearance distances. - The electrical creepage and clearance distances shall be in accordance with Specification MIL-E-917. 3.8 Type B - blower heat
24、ers. - 3.8.1 Ratings. - Heaters shall be furnished in the ratings specified in 1.2. 3.8.1.1 Heaters rated at 250 volts, d. c. (see 1.2) shall be capable of satisfactory operation over 2 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-a voltage range
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NAVYMILH226631960HEATERSSPACEELECTRICBLOWERRADIANTANDTURRETNAVALSHIPBOARD 带电 空间 加热器 鼓风机 电炉 煤气炉 白炽 部分

链接地址:http://www.mydoc123.com/p-979470.html