1、= 999990b 2113909 129 MIL-DTL-82939( OS) 11 February 2000 MILITARY SPECIFICATION SEPARATOR, EXPLOSIVE (1W18) This specification is approved for use by the Naval Sea Systems Command, Department of the Navy, and is available for use by all Departments and Agencies of the Departments of Defense. 1. SCO
2、PE 1.1 Scope. This specification covers the requirements for an Explosive Separator (1 W 18), Drawing 838AS220, hereto referred to as separator and its explosive component BBU-55/B explosive bolt, drawing 838AS221. 2. APPLICABLE DOCUMENTS 2.1 General. The documents listed in this specification are s
3、pecified in sections 3 and 4 of this specification. This section does not include documents cited in other sections of this specification or recommended for additional information or as examples. While every effort has been made to ensure the completeness of this list, document users are cautioned t
4、hat they must meet all specified requirments documents cited in sections 3 and 4 of this specification, whether or not they are listed. 2.2 Government documents. 2.2.1 Specifications and standards. The following specifications and standards form a part of this document to the extent specified herein
5、. Unless otherwise specified, the issue of these documents are those listed in the issue of the Department of Defense Index of Specifications and Standards (DoDISS) and supplement thereto, cited in the solicitation (see 6.2). SPECIFICATIONS DEPARTMENT OF DEFENSE MIL-1-23659 Initiators, Electrical, G
6、eneral Design Specification for I I Beneficial comments (recommendations, additions, deletions) and any pertinent data which may be of use in improving this document should be addressed to: Commander, Indian Head Division, Naval Surface Warfare Center, Standardization Team (Code 840M), 101 Strauss A
7、venue, Indian Head, MD 20640-5035, by using the Standardization Document Improvement Proposai (DD Form 1426) appearing at the end of this document or by I sending a letter. AMSC NIA FSC 1377 DISTRIBUTION STATEMENT A: Approved for public release; distribution is unlimited. Provided by IHSNot for Resa
8、leNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-82939(OS j STANDARDS DEPARTMENT OF DEFENSE MIL-STD-1168 Ammunition Lot Numbering and Ammunition Data Card (Unless otherwise indicated, copies of federal and military specifications and standards are available from Standar
9、dization Documents Order Desk, Bldg. 40,700 Robbins Avenue, Philadelphia, PA 191 11-5094.) 2.2.2 Other Government documents, drawings, and publications. The following other Government documents, drawings, and publications form a part of this document to the extent specified herein. Unless otherwise
10、specified, the issues are those cited in the solicitation. DRAWINGS Naval Air Systems Command (CAGE Code 30003 j 838AS220 Explosive Separator 83 8AS 22 1 838AS222 ShocWibration Test Fixture Bolt, Explosive, BBU-55/B (Application for copies should be addressed to: Commander, Indian Head Division, Nav
11、al Surface Warfare Center, Attn: Data Control Branch (Code 8410), Indian Head, MD 20640-5035.) 2.3 Non-Government publications. The following documents form a part of this document to the extent specified herein. Unless otherwise specified, the issues of the documents which are DoD adopted are those
12、 listed in the issue of the DoDISS cited in the solicitation. Unless otherwise specified, the issues of documents not listed in the DoDISS are the issues of the documents cited in the solicitation (see 6.2). Holex Dwg. F10369 Rev E Fixture AMERICAN SOCIETY FOR TESTING (2) body, release end down; (3)
13、 horizontal. Use a new separator for each drop. The separators shall not fire when dropped from a height of 6 feet. Each separator shall meet the post-test inspections of Table I and functional performance requirements. 4.4.14 Functional (destructive) tests. One-half of the LAT sample shall be subje
14、cted to functional testing at 165F and the other half at -65F. The temperature conditioning time shall be a minimum of 4 hours after temperature stabilization and a maximum of 24 hours at the respective temperature. The tests at each respective temperature shall be conducted with one-half the sample
15、 at extreme load (see 3.4.4) and the other half with no load present. if the sample is not evenly divisible by four, priority of test conditions shall be at the discretion of Naval Surface Warfare Center, Indian Head, Maryland. The functional test shall be performed in a test fixture (Holex drawing
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NAVYMILDTL829392000SEPARATOREXPLOSIVE1W18 炸药 分离器 W18PDF

链接地址:http://www.mydoc123.com/p-978926.html