NAVY MIL-DTL-60553 D-2005 CARTRIDGE DELAY M90 ASSEMBLY《M90组延时弹筒》.pdf
《NAVY MIL-DTL-60553 D-2005 CARTRIDGE DELAY M90 ASSEMBLY《M90组延时弹筒》.pdf》由会员分享,可在线阅读,更多相关《NAVY MIL-DTL-60553 D-2005 CARTRIDGE DELAY M90 ASSEMBLY《M90组延时弹筒》.pdf(13页珍藏版)》请在麦多课文档分享上搜索。
1、MIL-DTL-60553D 3 March 2005 SUPERSEDING MIL-C-60553C 16 April 1990 DETAIL SPECIFICATION CARTRIDGE, DELAY, M90 ASSEMBLY This specification is approved for use by all Departments and Agencies of the Department of Defense. 1. SCOPE 1.1 Scope. This specification covers the requirements for the M90 Delay
2、 Cartridge (see 6.1). 2. APPLICABLE DOCUMENTS 2.1 General. The documents listed in this section are specified in sections 3, 4 or 5 of this specification. This section does not include documents cited in other sections of this specification or recommended for additional information or as examples. W
3、hile every effort has been made to ensure the completeness of this list, document users are cautioned that they must meet all specified requirements of documents cited in sections 3, 4 or 5 of this specification, whether or not they are listed. 2.2 Government documents. 2.2.1 Specifications, standar
4、ds, and handbooks . The following specifications, standards, and handbooks form a part of this document to the extent specified herein. Unless otherwise specified, the issues of these documents are those cited in the solicitation or contract. DEPARTMENT OF DEFENSE SPECIFICATIONS MIL-A-2550 Ammunitio
5、n, General Specification for MIL-A-8625 Coating, Anodic, Conventional for Aluminum and Aluminum Alloy DEPARTMENT OF DEFENSE STANDARDS MIL-STD-810 Environmental Test Methods and Engineering Guidelines AMSC N/A FSC 1377 DISTRIBUTION STATEMENT A: Approved for public release; distribution is unlimited.
6、INCH POUND Comments, suggestions, or questions on this document should be addressed to Commander, Indian Head Division, Naval Surface Warfare Center, Technical Information Branch (Code 4230), 101 Strauss Avenue, Indian Head, Maryland 20640-5035, or emailed to amanda.pennnavy.mil. Since contact infor
7、mation can change, you may want to verify the currency of this address information using the ASSIST Online database at http:/assist.daps.dla.mil/ Source: http:/assist.daps.dla.mil - Downloaded: 2005-06-22T14:11ZCheck the source to verify that this is the current version before use.Provided by IHSNot
8、 for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-60553D 2 (Copies of these documents are available online at http:/assist.daps.dla.mil/ or from the Standardization Document Order Desk, 700 Robbins Avenue, Building 4D, Philadelphia, PA 19111-5094.) 2.2.2 Other G
9、overnment documents, drawings, and publications . The following other Government documents, drawings, and publications form a part of this document to the extent specified herein. Unless otherwise specified, the issues of these documents are those cited in the solicitation or contract. Drawings 5185
10、050 M90 Closed Bomb Assembly (5.747 in3) DL8596123 Cartridge, Delay, M90 Assembly 8845190 Carton, Packing, Ammunition, For Cartridge, Delay: M46, M71, M90, XM102, XM103, XM104, XM105, or M114 8845191 Box, Packing, Ammunition, For Cartridge, Delay: M46, M71, M90, XM102, XM103, XM104, XM105, or M114 9
11、227731 Carton, Alternative, Packing, Ammunition, For Cartridge, Delay: M46, M71, M90, XM102, XM103, XM104, XM105, or M114 851AS110 Ignition Device PVU-1/A Weapon Specifications WS 21535 Ignition Devices, (Percussion), PVU-1/A (Application for copies should be addressed to: Commander, Indian Head Div
12、ision, Naval Surface Warfare Center, Attn: Technical Information Branch (Code 4230), Indian Head, MD 20640-5035.) 2.3 Non-Government publications. The following documents form a part of this document to the extent specified herein. Unless otherwise specified, the issues of these documents are those
13、cited in the solicitation or contract. AMERICAN SOCIETY FOR TESTING AND MATERIALS (ASTM) ASTM E1742 Standard Practice for Radiographic Examination (Copies of this document are available online at http:/www.astm.org/ or from the American Society for Testing and Materials Customer Service, 100 Barr Ha
14、rbor Drive, West Conshohocken, PA 19428-2959.) AMERICAN NATIONAL STANDARD INSTITUTE/AMERICAN SOCIETY FOR QUALITY ANSI/ASQ Zl.4 Sampling Procedures and Tables for Inspection by Attributes ANSI/ASQ A8402 Quality Management and Quality Assurance - Vocabulary (Copies of these documents are available onl
15、ine at http:/webstore.ansi.org/ansidocstore/default.asp, or from the American Society for Quality, PO Box 3005, 611 E. Wisconsin Ave., Milwaukee, WI 53201-4606.) 2.4 Order of precedence. In the event of a conflict between the text of this document and the references cited herein (except for related
16、specification sheets), the text of this document takes precedence. Nothing Source: http:/assist.daps.dla.mil - Downloaded: 2005-06-22T14:11ZCheck the source to verify that this is the current version before use.Provided by IHSNot for ResaleNo reproduction or networking permitted without license from
17、 IHS-,-,-MIL-DTL-60553D 3 in this document, however, supersedes applicable laws and regulations unless a specific exemption has been obtained. 3. REQUIREMENTS 3.1 First article. When specified in the contract or purchase order, a first article sample shall be subjected to first article inspection (s
18、ee 4.4, 6.2, and 6.3). 3.2 Conformance to documents. The M90 Delay Cartridge covered by this specification shall be manufactured in accordance with DL8596123 and all documents listed thereon. 3.3 Materials. All materials used in the manufacture of the cartridges shall conform strictly to the specifi
19、cations referred to on the respective drawings unless specific approval in writing covering a departure therefrom has been obtained from the cognizant Navy design activ ity prior to manufacture. When alternate materials or methods of manufacture are specified on the drawings, the bidders selections
20、shall be clearly stated in the proposal. 3.4 Components. 3.4.1 Primary components. For the purpose of this specification, the PVU-1/A Ignition Device, M14 Delay Element, Igniter Charge and the cartridge propellant charge are considered primary components. Only primary components from a single lot sh
21、all be used in a production lot of cartridges; however, one primary component production lot may be used in more than one cartridge production lot. 3.4.1.1 Ignition device. The ignition device shall be furnished from lots manufactured within the preceding 24 months or recertified within the precedin
22、g 12 months. The ignition device shall be manufactured per Drawing 851AS110 and accepted per WS 21535. Prior to assembly into a cartridge, the ignition device shall be radiographically examined for defects as specified in 4.7.1. 3.4.2 Hardness. The hardness of each component part shall be in accorda
23、nce with the applicable drawing (see 4.7.2). 3.4.3 Protective finish. The finish of each component part shall be in accordance with MIL-A-8625 and the applicable drawing (see 4.7.3). 3.5 Assembly. 3.5.1 Radiographic examination. Each cartridge assembly shall be radiographically examined for defects
24、(see 4.7.4). 3.5.2 Leak Test. Each assembled cartridge shall exhibit no air leakage greater than 1 x 10-4 standard cubic centimeters per second (see 4.7.5) at a 14.7 psia pressure differential. 3.5.3 Vibration. The assembled cartridge shall withstand vibration as prescribed in MIL-STD-810, Method 51
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NAVYMILDTL60553D2005CARTRIDGEDELAYM90ASSEMBLYM90 延时 PDF

链接地址:http://www.mydoc123.com/p-978857.html