1、INCH-POUNDMIL-DTL-60286C12 September 2000SUPERSEDING MIL-I-60286B21 September 1992DETAIL SPECIFICATIONINITIATOR, CARTRIDGE ACTUATED, M53 ASSEMBLYThis specification is approved for use by all Departments and Agencies of the Department of Defense.1. SCOPE1.1 Scope. This specification covers the requir
2、ements for the M53 Cartridge Actuated InitiatorAssembly (see 6.1). 2. APPLICABLE DOCUMENTS2.1 General. The documents listed in this section are specified in sections 3 and 4 of this specification.This section does not include documents cited in other sections of this specification or recommended for
3、additional information or as examples. While every effort has been made to ensure the completeness ofthis list, document users are cautioned that they must meet all specified requirements documentsspecified in sections 3 and 4 of this specification, whether or not they are listed.2.2 Government docu
4、ments.2.2.1 Specifications and standards. The following specifications and standards form a part of thisdocument to the extent specified herein. Unless otherwise specified, the issues of these documents arethose listed in the Department of Defense Index of Specifications and Standards (DODISS) andsu
5、pplement thereto, cited in the solicitation (see 6.2).SPECIFICATIONSDEPARTMENT OF DEFENSEMIL-A-2550 Ammunition, General Specification ForMS28741 Hose Assembly, Detachable End Fitting, Medium PressureBeneficial comments (recommendations, additions, deletions) and any pertinent data which may be of us
6、e inimproving this document should be addressed to: Commander, Indian Head Division, Naval Surface WarfareCenter, Standardization Team (Code 840M), 101 Strauss Avenue, Indian Head, MD 20640-5035 by using theStandardization Document Improvement Proposal (DD Form 1426) appearing at the end of this doc
7、ument, or bysending a letter.AMSC N/A FSC 1377DISTRIBUTION STATEMENT A: Approved for public release; distribution is unlimited.Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-60286C2MIL-DTL-48412 Initiator, Cartridge Actuated, Delay, M53 Rema
8、nufactured Metal PartsAssemblyMIL-DTL-60519 Initiator, Cartridge Actuated, M53 Metal Parts AssemblySTANDARDSDEPARTMENT OF DEFENSEMIL-STD-1168 Ammunition Lot Numbering(Unless otherwise indicated, copies of Department of Defense specifications and standards are availablefrom: Standardization Documents
9、 Order Desk, Bldg. 4D, 700 Robbins Avenue, Philadelphia, PA 19111-5094.)2.2.2 Other Government documents, drawings, and publications. The following other Governmentdocuments, drawings, and publications form a part of this document to the extent specified herein. Unlessotherwise specified, the issues
10、 are those cited in the solicitation.DRAWINGSNaval Surface Warfare Center, Indian Head (CAGE Codes 19200 and 19203)8597230 Cartridge, Impulse, M91 Assembly10520619 Initiator, Cartridge Actuated, M53 Assembly(Application for copies should be addressed to Commander, Naval Surface Warfare Center, India
11、n HeadDivision, 101 Strauss Avenue, Data Control Branch (Code 8410), Indian Head, MD 20640-5035.)2.3 Non-Government publications and drawings. The following documents form a part of thisdocument to the extent specified herein. Unless otherwise specified, the issues of the documents whichare DOD adop
12、ted are those listed in the issue of the DODISS cited in solicitation. Unless otherwisespecified, the issues of documents not listed in the DODISS are the issues of the documents cited in thesolicitation (see 6.2).PUBLICATIONSAMERICAN SOCIETY FOR QUALITY CONTROLASQC Z1.4 Sampling Procedures and Tabl
13、es for Inspection by AttributesASQC A8402 Quality Management and Quality Assurance Vocabulary(Application for copies should be addressed to the American Society for Quality Control, PO Box 3005,611 E. Wisconsin Ave., Milwaukee, WI 53201-4606.)Provided by IHSNot for ResaleNo reproduction or networkin
14、g permitted without license from IHS-,-,-MIL-DTL-60286C3AMERICAN SOCIETY FOR TESTING AND MATERIALS (ASTM)ASTM E 1742 Standard Practice for Radiographic Examination(Application for copies of ASTMs should be sent to the American Society for Testing and Materials, 100Barr Harbor Drive, West Conshohocke
15、n, PA 19428-2959)2.4 Order of precedence. In the event of a conflict between the text of this document and thereferences cited herein (except for related associated specifications or specification sheets), the text ofthis document takes precedence. Nothing in this document, however, supersedes appli
16、cable laws andregulations unless a specific exemption has been obtained.3. REQUIREMENTS3.1 Materials. All materials used in the manufacture of the initiators shall conform to the specificationsreferred to on the respective drawings unless specific approval in writing covering a departure therefromha
17、s been obtained from the cognizant Navy design activity prior to manufacture. When alternatematerials or methods of manufacture are specified on the drawings, the bidders selections shall be clearlystated in the proposal. 3.2 Components.3.2.1 Primary components. For the purpose of this specification
18、, the M91 impulse cartridge (Drawing8597230) is defined as a primary component. Only primary components from a single lot shall be used ina production lot of initiators; however, one primary component production lot may be used in more thanone initiator production lot. 3.2.2 Component parts. All com
19、ponent parts shall meet the applicable requirements ofMIL-DTL-48412 or MIL-DTL-60519 prior to assembly. 3.3 Breakaway torque. The chamber and cap of each assembled initiator shall withstand a breakawaytorque application of 400 inch-pounds without loosening or deformation (see 4.3.1). 3.4 Residual ma
20、gnetism. The initiator shall not deflect the indicator of the compass more than fivedegrees in either direction (see 4.3.2). 3.5 Radiographic examination. Each initiator assembly shall be radiographically examined for defects(see 4.3.3). 3.6 Functional.3.6.1 Ballistics. Initiators loaded with cartri
21、dges from one accepted lot and temperature conditionedshall perform within the pressure values and delay times (see 6.4.1) specified in table I. Pressure valuesshall be recorded at the end of 15 feet of aircraft hose, assembly number MS28741-4, and a pressurechamber with a volume of 1 cubic inch. Pr
22、ovided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-60286C43.6.1.1 Initiation. The initiator shall be fired by a source delivering an output pressure of 700 +25, -0pounds per square inch gage (psig) at 70 5bF. 3.6.2 Misfires. There shall be no misf
23、ires. 3.6.3 Mechanical failures. The initiator shall function without mechanical failure (see 6.4.2). TABLE I. Pressure values.Temperature (bF) Pressure (psig) Ignition delay milliseconds,maxMinimum Maximum-60 to -70 500 1425 6565 to 75 600 1550 65195 to 205 700 1700 653.7 Workmanship. Initiators sh
24、all be free of cracks, splits, or other defects which might prevent propermating with connecting parts or proper functioning of the device. 3.7.1 Metal defects. All components shall be free from cracks, splits, cold shuts, inclusions, porosity, orany similar defect. 3.7.2 Burr. No part shall have a
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NAVYMILDTL60286C2000INITIATORCARTRIDGEACTUATEDM53ASSEMBLYM53 延时 驱动 引发 PDF

链接地址:http://www.mydoc123.com/p-978850.html