NAVY MIL-DTL-24643 2 F-2009 CABLE ELECTRICAL -20 DEGREE C TO +90 DEGREE C 300 VOLTS TYPE LSDCOP AND LSTCOP《LSDCOP及LSTCOP型300 V -20 ℃~+90 ℃电缆》.pdf
《NAVY MIL-DTL-24643 2 F-2009 CABLE ELECTRICAL -20 DEGREE C TO +90 DEGREE C 300 VOLTS TYPE LSDCOP AND LSTCOP《LSDCOP及LSTCOP型300 V -20 ℃~+90 ℃电缆》.pdf》由会员分享,可在线阅读,更多相关《NAVY MIL-DTL-24643 2 F-2009 CABLE ELECTRICAL -20 DEGREE C TO +90 DEGREE C 300 VOLTS TYPE LSDCOP AND LSTCOP《LSDCOP及LSTCOP型300 V -20 ℃~+90 ℃电缆》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、 INCH-POUND MIL-DTL-24643/2F 1 October 2009 SUPERSEDING MIL-DTL-24643/2E 22 August 2002 DETAIL SPECIFICATION SHEET CABLE, ELECTRICAL, -20 C TO +90 C, 300 VOLTS, TYPE LSDCOP AND LSTCOP This specification is approved for use by all Departments and Agencies of the Department of Defense. The requirement
2、s for acquiring the product described herein shall consist of this specification sheet and MIL-DTL-24643. Construction, Non-Watertight First - Copper conductor, coated or uncoated (see table I for size). Second - Separator may be used at manufacturers option where required to provide free-stripping
3、insulation. Third - Thermoset insulation with minimum average wall thickness of 0.015 inch. Standard identification code applied by Method 3. Fourth - The specified number of conductors (see table I) shall be cabled together with a left-hand lay. The length of lay shall be as required for the comple
4、ted cable to meet the twisting and bending endurance tests. A tie cord shall be laid straight as a central core in LSDCOP-1. Fillers may be used as necessary to form a firm well-rounded assembly. Fifth - An optional binder. Sixth - Cross-linked polyolefin jacket. Minimum average wall thickness of 0.
5、030 inch. NOTE: Because of the peculiar lay-up of LSDCOP-1 cable, the centering and circularity requirements shall not apply. AMSC N/A FSC 6145 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-24643/2F TABLE I. Details. Conductors Overall diam
6、eter Military part no. M24643/2 Type and size No. Size AWG Conductor resistance (ohms) min. (inch) max. (inch) -01UN LSDCOP-1 2 20 (Class B) 11.42 0.235 0.250 -02UN LSDCOP-1 2 18 (Class K) 9.00 0.300 0.315 -03UN LSDCOP-2 2 18 (Class K) 7.16 0.310 0.330 -04UN LSTCOP-2 3 18 (Class K) 7.16 0.325 0.345
7、REQUIREMENTS: Qualification required. INSPECTION: Basic Electricals: Conductor resistance (ohms/1000 feet at 25 C, max.) See table I Voltage withstand (volts, root mean square, min.) Conductor to conductor 1500 Insulation resistance (megohms/1000 feet, min.) Conductor to conductor 100 Conductor cont
8、inuity No failure Group A: Visual and dimensional No failure Group B: Thermoset proof test (percent, max.) Insulation 50 Jacket (when tested at 200 C) 50 Twisting and bending endurance At 75 C (cycles, min.) 6000 At minus 302 C (cycles, min.) 2000 NOTE: Roller diameters for bending endurance test sh
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NAVYMILDTL246432F2009CABLEELECTRICAL20DEGREECTO90DEGREEC300VOLTSTYPELSDCOPANDLSTCOPLSDCOP LSTCOP 300

链接地址:http://www.mydoc123.com/p-978644.html