《NAVY MIL-DTL-24640 16 E-2011 CABLE ELECTRIC -20 TO +105 癈 600 VOLTS LIGHTWEIGHT MULTI-PAIR 18 AWG TYPE 2XSW (INCLUDING VARIATION TYPE 2XSOW)《2XSW型18 AWG多对轻量600V -20 ℃~+105 ℃电缆(包括变化型2XSOW)》.pdf》由会员分享,可在线阅读,更多相关《NAVY MIL-DTL-24640 16 E-2011 CABLE ELECTRIC -20 TO +105 癈 600 VOLTS LIGHTWEIGHT MULTI-PAIR 18 AWG TYPE 2XSW (INCLUDING VARIATION TYPE 2XSOW)《2XSW型18 AWG多对轻量600V -20 ℃~+105 ℃电缆(包括变化型2XSOW)》.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、AMSC N/A FSC 6145 INCH-POUND MIL-DTL-24640/16E 8 November 2011 SUPERSEDING MIL-DTL-24640/16D 22 August 2002 DETAIL SPECIFICATION SHEET CABLE, ELECTRIC, -20 TO +105 C, 600 VOLTS, LIGHTWEIGHT, MULTI-PAIR, 18 AWG, TYPE 2XSW (INCLUDING VARIATION TYPE 2XSOW) This specification is approved for use by all
2、Departments and Agencies of the Department of Defense. The requirements for acquiring the product described herein shall consist of this specification sheet and MIL-DTL-24640. Construction (Watertight) First - Tin-coated copper conductor in accordance with table I. Second - Insulation material and b
3、asic construction requirements shall be in accordance with SAE-AS81044/12 and tested in accordance with the component wire ratings and requirements listed on this specification sheet. Conformance testing shall be in accordance with SAE-AS81044 prior to cabling. Third - Two conductors, one black and
4、one white, twisted together. The pitch shall be 1 inch. Fourth - Optional binder tape. Fifth - Braided shield of 38 AWG tin-coated copper strands. Braid coverage shall be no less than 90 percent determined in accordance with WC-27500. Sixth - Shield insulation of two polyester tapes or polyester tap
5、e and extruded jacket. Identification codes applied using Method 2. (NOTE: This step is not required for Type 2XSW1.) Seventh - The required number of shielded, twisted pairs shall be cabled together. Cabling sequence shall be consecutive, starting with number 1 from center outward. Fillers may be u
6、sed, as necessary, to form a round cable. Eighth - Optional binder tape. Construction Variant for Type 2XSW Ninth - Cross-linked polyolefin jacket (see table II for thickness). NOTE: Manufacturers identification tape or thread is required (see 3.7.3). Construction Variant for Type 2XSOW Ninth - Brai
7、ded shield, tin-coated copper strands. Braid must be constructed to meet surface transfer impedance requirements as listed herein. Tenth - Optional binder tape. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-24640/16E 2 Eleventh - Cross-link
8、ed polyolefin jacket (see table III for thickness). NOTE: Manufacturers identification tape or thread is required (see 3.7.3). TABLE I. Component wire details. Watertight conductor Finished wire Wire size (AWG) Stranding (no. x AWG) Test load life cycle accelerated aging tests (lbs 3%) Low temp. at
9、-40 C Mandrel diameter (inches) Test load (lbs) 18 7 x 26 0.250 1.0 1.0 TABLE II. Construction details. PIN M24640/16 Type number Number of pairs Jacket thickness (inch) (min.) Cable diameter (inch) Cable weight (pounds per 1000 feet) (max.) (min.) (max.) -01UN -02UN -03UN 2XSW-1 2XSW-3 2XSW-7 1 3 7
10、 0.034 0.041 0.044 0.240 0.436 0.573 0.258 0.470 0.617 52.9 175.0 330.0 TABLE III. Construction details - overall shield. PIN M24640/16 Type number Number of pairs Jacket thickness (inch) (min.) Cable diameter (inch) Cable weight (pounds per 1000 feet) (max.) (min.) (max.) -01UO -02UO -03UO -04UO -0
11、5UO 2XSOW-3 2XSOW-7 2XSOW-12 2XSOW-19 2XSOW-30 3 7 12 19 30 0.041 0.044 0.047 0.050 0.057 0.487 0.608 0.802 0.938 1.180 0.525 0.656 0.864 1.010 1.270 227.0 401.0 665.0 950.0 1442.0 REQUIREMENTS: Qualification required. Construction details: See tables I, II, and III. Component wire: The component wi
12、re shall be in accordance with SAE-AS81044 and shall be tested in accordance with the following wire ratings and additional requirements. Temperature rating 135 C (275 F) (max.) conductor temperature Voltage rating 600 volts (root mean square) at sea level Accelerated aging Oven temperature, 2502 C
13、(4823.6 F) for 6 hours Low temp. cold bend -40 C (-40 F) for 4 hours Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-24640/16E 3 Blocking 1502 C (3023.6 F) Color In accordance with MIL-STD-104, Class 1; white preferred Flammability 30 seconds
14、 (max.) 3.0 inches (max.) No flaming of tissue paper Humidity resistance 5000 megohms for 1000 feet (min.) insulation resistance after humidity exposure Dielectric test Primary insulation 6.0 kilovolts (peak), 100 percent impulse test (when tested in lieu of spark test) Finished wire 8.0 kilovolts (
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NAVYMILDTL2464016E2011CABLEELECTRIC20TO105 600 VOLTSLIGHTWEIGHTMULTIPAIR18AWGTYPE2XSWINCLUDINGVARIATIONTYPE2XSOW2XSW

链接地址:http://www.mydoc123.com/p-978614.html