NAVY MIL-C-85077-1977 CAPS BLASTING SPECIAL《特殊爆破雷管》.pdf
《NAVY MIL-C-85077-1977 CAPS BLASTING SPECIAL《特殊爆破雷管》.pdf》由会员分享,可在线阅读,更多相关《NAVY MIL-C-85077-1977 CAPS BLASTING SPECIAL《特殊爆破雷管》.pdf(11页珍藏版)》请在麦多课文档分享上搜索。
1、MIL-C-85077 13 7779706 0363643 ?! a 737y7 e-!- MIL-C-85077 (AS) 12 December 1977 1.11 LI TARY SPEC I FI CATI ON CAPS, BLASTING, SPECIAL This specification is approved for use by the Naval Air Systems Command, Department of the Navy, and is available for use by all Departments and Agencies of the Dep
2、artment of Defense. 1. Scope. This specification covers electric, shielded blasting caps for use in detonating explosives (see 6.1). 2. APPLICABLE DOCUMENTS 2.1 invitation For bids or request for proposal, form a part of this speci- fication to the extent specified herein: The following documents of
3、 the issue in effect on date of S P EC I F I CAT I ONS Federal W-B-41 l B1 acting-Apparatus (Machines , B1 asting; Gal va- nometers and Rheostats for Testing Blasting Circuits and Machines) QQ-A-250/8 Aluminum Alloy 5052; Plate and Sheet QQ-L-201 Lead, Sheet PPP-B-621 Box, Wood, Nailed and Lock Corn
4、er PPP-B-636 BOX, Fi berboard PPP-B-1055 -Barrier Material , Waterproofed, F1 exi bl e Beneficial comments, (recommendations, additions, deletions) and any pertinent data which may be of use in improving this document should be addressed to: 93, Naval Air Engineering Center, Lakehurst, NJ 08733 by u
5、sing the self -addressed Standardization Document Improvement Proposal (DD Form 1426) appearinq at the end of this document or b.y letter. Engineering Specifications and Standards Department, Code I i i , THIS DOCUMENT CONTAINS i PAGES. ?-., Provided by IHSNot for ResaleNo reproduction or networking
6、 permitted without license from IHS-,-,-MIL-STD-129 MI L-STD- 1461 Marking- For Shipment and Storage Ammuni tion Manufacturers and Their Symbols PUBLICATIONS Department of Defense 4145.26M DoD Contractors Safety Manual for Ammunition, Explosives and Re1 ated Dangerous Materials (Copies of specificat
7、ions, standards, drawings, and pub1 ications required by contractors in connection with specific procurement functions should be obtained from the procuring agency or as drected by the con- tracti ng offi cer . ) 2.2 Other publications. The following document forms a part of this specification to th
8、e extent specified herein. The issue in effect on date of invitation for bids or request for proposal shall apply. CODE OF FEDERAL REGULATIONS 49 CFR 171-178 Hazardous Materials Regulations, Department (Copies are available from the Superintendent of Documents, Govern- of Transportation ment Printin
9、g Office, Washington, DC 20402.) 3. REQUIREMENTS 3.1 caps shall be as specified herein. shall be of the best quality normally used for the purpose in good com- mercial practice. The materials shall be free of all defects and imper- fections that might affect the serviceability of the finished produc
10、t. Material. The materials used in the manufacture of the blasting All materials not definitely specified 2 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-
11、,-,-MIL-C-5077 13 = 9777706 O363646 4 MIL- C-85077 (AS) 3.3 Details of assembly. The base- charge shall be compressed into the shell. A primer charge, or a primer and ignition charge, shall be placed in the shell. The caps shall be provided with a pair of copper lead wires, approximately 24 feet in
12、length, in accordance with the MIL-C-27500, cable designation 22ML2T08, sealed into the cap to make a waterproof assembly. The shielding shall be electrically connected to the cap and to a female connector with a conductive material (solder, braze, or a conductive epoxy such as Emerson and Cuming, I
13、nc., Type 72- G) throughout their respective entire peripheries to form a continuous shield without electrical discontinuities or gaps. The pins on the inner conductors of the connector shall be female and recessed into the insulator to prevent unintentional contact by fingers or tools. In addition,
14、 the tips of the female pins shall be recessed well below the lip of the surrounding shield to provide additional shielding. The shielded lead wires shall be covered with a heat shrinkable, flexible, insulation sleeving of appropriate quality. A metal-cased male plug, designed to completely mate wit
15、h the outer shell (shield) surface before any of its inner shorted conductors make contact with the recessed pins of the connector, when being unmated, shall completely open-circuit the female conductor pins before the shell (shield) contact surface has broken contact, The female connector and plug
16、shall be approved by the contracting officer. The outside of the blasting cap shell shall be legibly marked with the manufacturers code number per MIL-STD-1461. One male plug with 36 inch leads compatible to female connector, shall be.provided with each package of 10 blasting caps for detonation use
17、. 3.4 Functioning. 3.4.1 Electrical resistance. The resistance of the complete cap assembly, including its leads, shall be 2.2 5 0.5 ohms when tested as specified in 4.5.3.1. 3.4.2 Waterproofness. The caps shall withstand submersion in water for a period of 4 hours at a temperature of 70 Fahrenheit
18、(F) 55 and a pressure of 50 pounds per square inch (psi) as specified in 4.5.3.2. Following the test, the caps shall function satisfactorily, as evidenced by the perforation of the lead discs when the caps are tested as specified in 4.5.3.2 and 4.5.4.1, and shall either: (a) Function upon applicatio
19、n of an electric current of 1.5 amperes for a period not exceeding 50 milliseconds, as specified in 4.5.3.2, or 4 . . . . . - . - : - i . . ._ Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-1 MIL-C-5077 23 W 7797706 03636117 b M MIL-C-85077( AS) (b)
20、 Function through a total resistance of 32 ohms when fired with a blasting machine, as specified in 4.5.3.2. 3.5 Current requirements. 3.5.1 Functioning. The electric caps shall fire when an electric current of 0.45 ampere is applied. 3.5.2 Nonfunctioning. The electric caps shall not fire when an el
21、ectric current of 0.2 ampere is applied for 5 seconds, as specified in 4.5.5.1. 3.5.3 Firing time. The caps shall fire in accordance with table II. 3.6 Safety. The supplier shall observe the safe practices and standards set forth in DoD 4145.26M. 3.7 Workmanship. All parts shall be free of chips, di
22、rt, grease, rust, and other foreign material. The cleaning method used shall not be injurious to any of the parts nor shall the parts be contaminated by the. cleaning agents used. 4. QUALITY ASSURANCE PROVISIONS 4.1 Responsibility for-inspection. Unless otherwise specified in the contract or purchas
23、e order, the supplier is responsible for the per- formance of all inspection requiremenix as specified herein. Except as otherwise specified in the contract or order, the supplier may use his own or any other facilities suitable for the performance of the inspec- tion requirements specified herein,
24、unless disapproved by the Government. The Government reserves the right to perform any of the inspections set forth in the specification where such inspections are deemed necessary to assure supplies and services conform to prescribed requirements. 4.2 - Lot. A lot shall consist of blasting caps pro
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NAVYMILC850771977CAPSBLASTINGSPECIAL 特殊 爆破 雷管 PDF

链接地址:http://www.mydoc123.com/p-978154.html