1、Actuator Assembly Test Set, and all documents listed thereon Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-3 Provided by IHSNot for ResaleNo reproduct
2、ion or networking permitted without license from IHS-,-,-range -of zero to 20 microamperes. Placing the ISOLATION switch to EXT shall connect the actuator circuits and actuator frame across test jacks (MEGOHMS) on the test set panel, providing a capability for measuring iso- lation resistance with a
3、n external ohmmeter. 3.2.3.3 Motor drive control. The test set shall provide the following outputs to Actuator Assembly to control speed and direction of the actuator drive motors. Switches on the test set panel shall select the motor to be driven, speed, and the direction of drive. NORMAL - CW +36
4、*O. 5 volts at O. 7 ampere NORMAL - CCW -36 *O. 5 volts at O. 7 ampere SLOW - CW -1-10 therefore, there shall be no sampling plan for acceptance. Defective units shall be rejected. Acceptance Tess and Examinations (see 4.5) 4.4 Test conditions. Unless otherwise specified, the test set shall be subje
5、cted to tests under the following conditions: (a) Temperature Room ambient (60 to 95 degrees F) (b) Humidity (Relative) Room ambient, up to 95 percent (c) Altitude Normal ground atmospheric pressure Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL
6、-A-824.51 (OS) 4.5 Acceptance tests and examinations. Unless otherwise specified each test set delivered under contract shall be subjected to the tests and examina- tions contained in 4. 5. 3. 4. 5.1 Special notes. 4. 5.1.1 Calibration. Calibration of the actuator assembly test set should be perform
7、ed in accordance with WD 28936 and before conducting tests in 4.5.3. 4.5.1.3 Test results. Where space is provided in Appendix Report Form to indicate value or specific reading obtained, the specific reading shall be recorded if a limit or limits are given in Limits column for the test. If limits ar
8、e not stated in Limits column, the individual performing the test or inspection shall initial in space provided in the Reading column indicating that require- ments were met satisfactorily. 4.5.1.4 Acceptance criteria. Failure of the end product to pass any examination or test of this section will a
9、utomatically classi the unit as non- conforming. When nonconforming units are corrected by the contractor, the unit shall be reinspected. The reinspection of a nonconforming unit may be limited to the test or examination which defined the nonconformance, or when so directed by the cognizant inspecto
10、r, a complete re-examination and retest of the unit may be required. Nonconforming units, which have not been corrected, will be considered for acceptance only upon formal application, by the contractor to the Bureau of Naval Weapons via the cognizant Government representative. 4. 5.2 Acceptance tes
11、t equipment. Items of test equipment shown in table III are required to perform acceptance tests specified herein. All items of test equipment shall be of sufficient accuracy and precision to permit valid performance of required tests. Test instruments shall be calibrated at regular intervals and pr
12、ocedures for and results of all calibrations shall be subject to approval of the cognizant Government Inspector. Items having equivalent characteristics may be substituted where necessary. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-A-82451 1
13、3 m 9999906 043386b 7 m MIL-A-824.51 (OS) Table Di Test Equipment Item Oscilloscope: (DC to 15 mc pass band; 23 nanosec rise time; 20 mv/cm deflection factor 6 cm by 10 cm display graticule) Digital DC Voltmeter: (Range O. 001 to 999 v dc; accuracy: AO. 2% of reading, Al count) Low Frequency Functio
14、n Generator: (Frequency Range: O. 008 to 1200 cps in five decade ranges. Output Waveforms: Sinusoidal, square,. and triangular; Maximum Output Voltage: At least 30 volts peak-to-peak aoross rated load (4000 ohms) for all three waveforms; Frequency Response: Constant within O. 2 db) Resistor, 50 ohms
15、, 50 watt, 1/2%. Resistor, 100 ohms, 50 watt, 1%. Resistor, 2.25 megohm, 1/2 watt, 1% Note: All test equipment used shall be isolated from a-c line ground. Identification Teldronix, Model 531 with 53/54 D plug-in preamplifier Hewlett-Packard, Model 405 CR or 405 BR Hewlett-Packard, Model 202A 4.5.3
16、Test procedure. 4. 5. 3. 1 4. 5.3.1.1 Veri% that all power to the test set is off. 4. 5. 3.1.2 Connect a jumper between pin A and pin C of ACTUATOR Motor output test. 7 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-Provided by IHSNot for ResaleNo r
17、eproduction or networking permitted without license from IHS-,-,-9 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-A-824.51 (OS) Control Position MV/CM MULTLPLIER 2 VARIABLE CALIBRATED (FULLY CW) INPUT MODE A, DC 4. 5.3.2. 2 Connect low frequency
18、 function generator (signal generator) be- tween pins C and D of TEST FIXTURE INPUT connector located on the test set panel. Pin C connects to upper output terminal, pin D connects to lower output terminal. Do not connect ground strap. 4. 5.3.2.3 Connect input A of oscilloscope to upper output of si
19、gnal generator. Connnect oscilloscope ground to lower output terminal. Connect the SYNC OUT from signal generator to TRIGGER input of oscilloscope. Connect SYNC output ground to lower output terminal of signal generator. 4. 5.3.2.4 Set signal generator waveform to triangular and frequency to O. 5 cp
20、s. Set amplitude so that peak-to-peak value of waveform is approxi- mately 5 cm as indicated on oscilloscope. I 4.5.3.2. 5 4.5.3.2.6 Position DC PWR switch to ON. Turn TRIGGER STABILITY control CCW until oscilloscope I I cycle. If thfs- does not occur reverse dl leads connected to signal generator o
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NAVYMILA824511966ACTUATORASSEMBLYTESTSETFORTORPEDOMK46MOD1 装置 测试 设备 MK46MOD1 鱼雷 PDF

链接地址:http://www.mydoc123.com/p-977106.html