NAVY DOD-K-24674-1986 KIT DISSOLVED OXYGEN (METHOD C) NAVAL SHIPBOARD (METRIC)《海军船舷(方法C)溶解氧工具包(公制)》.pdf
《NAVY DOD-K-24674-1986 KIT DISSOLVED OXYGEN (METHOD C) NAVAL SHIPBOARD (METRIC)《海军船舷(方法C)溶解氧工具包(公制)》.pdf》由会员分享,可在线阅读,更多相关《NAVY DOD-K-24674-1986 KIT DISSOLVED OXYGEN (METHOD C) NAVAL SHIPBOARD (METRIC)《海军船舷(方法C)溶解氧工具包(公制)》.pdf(21页珍藏版)》请在麦多课文档分享上搜索。
1、LJ-26- 61 DOD-K-24674 bb m 7797706 0333337 T I I METRIC I DOD-K-Z4674(SH) 21 August 1986 MILITARY SPECIFICATION KIT, DISSOLVED OXYGEN (METHOD C), NAVAL SHIPBOARD (METRIC) This specification is approved for use within the Naval Sea Systems Command, Department of the Navy, and is available for use by
2、all Departments and Agencies of the Department of Defense. 1. SCOPE 1.1 Scope. This specification covers a water testing outfit using an organic dye for the determination of dissolved oxygen in feedwater. 2. APPLICABLE DOCUMENTS 2.1 Government documents. 2.1.1 Specifications and standards. The follo
3、wing specifications and standards form a part of this specification to the extent specified herein. Unless otherwise specified, the issues of these documents shall be those listed in the issue of the Department of Defense Index of Specifications and Standards (DoDISS) and supplement thereto, cited i
4、n the solicitation. SPECIFICATIONS FEDERAL PPP-B-566 - Boxes, Folding, Paperboard. PPP-B-636 - Boxes, Shipping, Fiberboard. PPP-B-640 - Boxes, Fiberboard, Corrugated, Triple-Wall. PPP-B-665 - Boxes, Paperboard, Metal Edged and Components. PPP-B-676 - Boxes, Setup. MI LITARY MIL-P-116 - Preservation,
5、 Methods of. Beneficial comments (recommendations, additions, deletions) and any pertinent data which may be of use in improving this document should be addressed to: Commander, Naval Sea Systems Command, SEA 5523, Department of the Navy, Washington, DC 20362-5101 by using the self-addressed Standar
6、dization.Document Improvement Proposal (DD Form 1426) appearing at the end of this document or by letter. 4MSC N/A FSC 6630 IISTRIBUTION STATEMENT A Approved for public release; distribution unlimited Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-S
7、TANDARDS WILITARY MIL-STD-105 - Sampling Procedures and Tables for Inspection by MIL-STD-129 - Narking for Shipment and Storage. Attributes. (Copies of specifications and standards required by contractors in connection with specific acquisition functions should be obtained from the contracting activ
8、ity or as directed by the contracting activity.) 2.2 Other publications. The following documents form a part of this specification to the extent specified herein. Unless otherwise specified, the issues of the documents which are noD adopted shall be those listed in the issue of the DoDISS specified
9、in the solicitation. the issues of documents not listed in the DoDISS shall be the issue of the nongovernment documents which is current on the date of the solicitation. Unless otherwise specified, AMERICAN SOCIETY FOR TESTING AND MATERIALS (ASTM) D 1133 - Standard Specification for Reagent Water. (
10、DoD adopted) D 3951 - Standard Practice for Commercial Packaging. (DoD adopted) (Application for copies should be addressed to the American Society for Testing and Materials, 1916 Race Street, Philadelphia, PA 19103.) (Nongovernment standards and other publications are normally available from the or
11、ganizations which prepare or which distribute the documents. These documents also may be available in or through libraries or other informational services.) 2.3 Order of precedence. In the event of a conflict between the text of :;.s specification and the references cited herein (except for associat
12、ed ciezail Specifications, specification sheets or MS standards), the text of this specification shall take precedence. Nothing in this specification, however, shall supersede applicable laws and regulations unless a specific exemption has been obtained. 3. REQUIREMENTS 3.1 Definition. The method C
13、dissolved oxygen test kit measures the mount of dissolved oxygen present in deaerated feedwater at the parts per billion (p/b) level. The kit consists of sampling equipment, clamp, glass sampler, rubber tubing, snapper, test eqiiipment, evacuated ampoules containing test chemicals, and a standard co
14、lor comparator. 3.2 First article. When specified in the contract or purchase order, a sample shall be subjected to first article inspection (see 4.2.1 and 6.3). 2 . Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-DOD-K-24b74 66 m 7779706 OL33L4l m 3
15、.3 Characteristics. 3.3.1 Performance. the amount of dissolved oxygen in deaerated feedwater having a temperature of 21 to 38 degrees Celsius (OC) (70 to 100 degrees Fahrenheit (OF) between O The method C dissolved oxygen test kit shall measure and 40 p/b. oxygen level when the actual oxygen value i
16、s less than 15 p/b and within plus or minus 5 p/b when the actual oxygen value is between 15 and 40 p/b. actual oxygen value is greater than 40 p/b the test shall indicate a value of greater than 40 p/b. Feedwater contaminents or treatment chemicals, chlorides and hardness or phosphates, morpoline,
17、EDTA and hydrazine, shall not interfere with the measurement of dissolved oxygen. The test results obtained shall be plus or minus 2.5 p/b of the When the 3.3.2 Physical characteristics. 3.3.2.1 Component parts. The method C dissolved oxygen test kit shall con- sist of the following: One colorimetri
18、c comparator with eight liquid color standards representing O, 5, 10, 15, 20, 25, 30 and 40 p/b dissolved oxygen, respectively One box of 30 ampoules One snapper tool One glass sampler One finger cot One utility clamp One chain type clamp One piece of 4.8 millimeters (mm) (3/16-nch) inside diameter
19、(id) One set of operating instructions One storage case neoprene tubing, 914.4 mm (3-foot) length 3.3.2.1.1 Colorimetric comparator. Details and dimensions of the color com- parator used for making the dissolved oxygen determinations shall be as shown on figure 1. The comparator shall consist of a t
20、ransparent tube in which eight liquid-filled glass vial color standards are mounted and enclosed. be a center space into which the test ampoule can be inserted for color compari- son. The comparator shall have the color standards representing O, 5, 10, 15, 20, 25, 30 and 40 p/b dissolved oxygen. The
21、se color standards shall range in color from clear to pink to reddish-pink. There shall 3.3.2.1.2 Test ampoules. Details and dimensions of the test ampoules used They in determining the dissolved oxygen content shall be as shown on figure 2. shall be made of glass, flat at one end and drawn to a tap
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NAVYDODK246741986KITDISSOLVEDOXYGENMETHODCNAVALSHIPBOARDMETRIC 海军 船舷 方法 溶解氧 工具包 公制 PDF

链接地址:http://www.mydoc123.com/p-976709.html