1、u I INCH-POUND A-A- 5 9 18 6 9 September 1998 COMMERCIAL ITEM DESCRIPTION WELL, HOT FOOD STORAGE, ELECTRIC (NAVAL SHIPBOARD) The General Services Administration has authorized the use of this comercial item description for all federal agencies. 1. SCOPE This commercial item description (CID) covers
2、electrically heated hot food storage wells of the drop-in type, with temperature control and drain. Wells shall be suitable for wet or dry operation. They are intended for Naval shipboard use in serving lines to keep food warm in steam table pans. 2. SALIENT CHARACTERISTICS 2.1 Design and constructi
3、on. The well shall be the drop-in type for counter or table installation. It shall consist of a seamless, drawn stainless steel pan and shall include: o Top perimeter supporting flanges b Integral drain Counter gasket b Heat distributing plate Heating element attached beneath the pan Insulation belo
4、w the heating element and along the sides Means of attaching the pan in the counter or table The well shall be encased by an outer housing of galvanized steel or other corrosion-resisting metal. A thermostatic control suitable for mounting in the counter front shall be provided, adjacent to the well
5、. The heating element and pilot light shall both energize when the control is turned on. Inside dimensions of the well pan shall be: 19-7/8 inches long by 11-7/8 inches wide by 6-1/8 inches deep (all with + 1/4 / - O inch tolerances). The perimeter flange shall be not less than 1/2 inch wide. The we
6、ll pan shall be a food zone as defined in the NSF standards. Beneficial comments, recommendations, additions, deletions, clarifications, etc., and any other data which may improve this document should be sent to: Commander, Naval Sea Systems Command, 2531 Jefferson-Davis Highway, Arlington, VA 22242
7、-5160. AMSC N/A FSC 7310 DISTRIBUTION STATEMENT A: Approved for public release; distribution is unlimited. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,- A-A-59L8b 9018054 00032b9 803 A-A-5 9 18 6 2.2 Heating system. A heat distributing plate, 1/8
8、f 1/32 inch thick and of adequate size to cover the flat surface of the bottom of the well, shall be welded or securely clamped to the underside of the well. The heating element shall be the enclosed tubular type rated at not less than 1500 watts and shall be securely clamped to the underside of the
9、 heat distributing plate. The heating element shall be removable without the use of special tools. (Shipboard requirement, see 6.2) 2.3 Temperature control unit. A thermostat of the infinite temperature control type with a clearly marked OFF position shall be provided. The temperature control unit s
10、hall provide temperature adjustment within a range of not less than 120 to 190F, and at an intermediate setting (approximately 15OoF), it shall limit temperature variation to not more than f 20F. The temperature control unit shall be suitable for mounting in the counter front adjacent to the well pa
11、n. The adjustment knob on the temperature control unit panel shall either be recessed or have a protective shield to prevent acciden- tal breakage. An indicator light shall also be provided on the temperature control unit panel and shall be illuminated when the heating element is energized. 2.4 Gask
12、et. A gasket shall be provided to give the joint between the top perimeter flange of the well pan and the mounting surface a positive moisture seal. 2.5 Thermal insulation. Blanket-type thermal insulation shall be provided between the heating element and the base of the outer casing, and between the
13、 sides of the well pan and outer casing. The temperature of the base of the outer casing shall be not greater than 125F. 2.6 Drain. A drain shall be provided in the base of the well pan for draining water when wet operation is required. The drain shall be a stainless steel pipe welded to the well pa
14、n or a brass pipe brazed to the pan, and shall have standard 3/4 NPT threads on the outlet end. The inlet end of the drain pipe shall be smooth and flush with the surface of the well pan. stainless steel inlet strainer screen shall be provided. (Shipboard requirement, see 6.2) An integral 2.7 Electr
15、ical requirements. The unit shall operate on 115 VAC, 60 Hz, single-phase power, as defined in MIL-STD-4399, Section 300, and shall have provisions for making direct (hardwired) connections for electric power (2 conductors) and for equipment grounding (1 conductor). All outermost metallic surfaces s
16、hall be grounded via the equipment grounding connection. The grounding resistance between any exposed metallic surfaces and the comon ground point shall be not greater than 0.1 ohm. Electrical components, other than the hermetically sealed motor, shall be provided in accordance with NEMA 250, Type 1
17、3 or equivalent enclosure protection. Metal parts of electrical components and enclosures shall be inherently corrosion resistant or shall be treated and processed for corrosion resistance in accordance with IEEE Standard 45. (Shipboard requirement, see 6.2) 2.8 Accessibility. The unit shall be phys
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NAVYAA591861998WELLHOTFOODSTORAGEELECTRICNAVALSHIPBOARD 海军 食品店 储藏 PDF

链接地址:http://www.mydoc123.com/p-976361.html