1、This document is restricted and may not be sent outside Navistar, Inc. or reproduced without permission from Corporate Technical Standards. Suppliers are required to assume all patent liability. 2017 by Navistar, Inc. MARCH 2017 Page 1 of 3 NAVISTAR, INC. Material, Parts, and Process Specifications
2、(MPAPS) NUMBER: MPAPS DT-15 Former Designation: CEMS DT-15 TITLE: TEST FOR HOSE INSERTION FORCE CURRENT REV No.: 1703 DATE: Mar. 2017 WRITTEN/REVIEWED BY: M. Ghaddar APPROVED BY: R. Goluch SUPERSEDES: February 2013 PRINTED COPIES OF THIS DOCUMENT MUST BE VERIFIED FOR CURRENT REVISION This specificat
3、ion may involve hazardous materials, equipment, and procedures. This specification does not purport to address all of the safety issues associated with its use. The user is responsible to consult appropriate safety and health practices and to determine the applicability of regulatory limits prior to
4、 use. 1.0 SCOPE Test method to determine the push on force for all Navistar rubber hoses under 30 mm inside diameter. This test is valid at 23o C 5o C. 2.0 RESTRICTED CHEMICAL SUBSTANCES Effective January 1, 2007, all product supplied to the requirements of this specification must comply with the re
5、quirements of the MPAPS B-50 specification. 3.0 REFERENCE DOCUMENTS Unless otherwise specified the latest issue of all reference standards shall apply. The following specifications and standards are referenced in this specification. NAVISTAR MPAPS F-1 NAVISTAR MPAPS B-50 4.0 APPARATUS 4.1 The fittin
6、g(s) used in the production assembly of the hose being tested. Alternately, a mandrel representing the maximum tolerance dimensions of the appropriate sized MPAPS F-1 fitting to be employed with the tested hose can be used. Fittings need to be fabricated so that they can thread into the load cell. 4
7、.2 Load cell capable of measuring peak load with a minimum resolution of 0.5 lbf. The load cell should be mounted firmly either in a vice or in fixture parallel to the floor, see Figure 1. 5.0 MATERIALS 5.1 The hose to be tested conditioned at room temperature for at least 4 hours. 5.2 Hose Joint Lu
8、bricant use the lubricant currently used in the assembly plants where this hose is assembled. NUMBER: MPAPS DT-15 TITLE Test for Hose Insertion Force CURRENT Rev No: 1703 This document is restricted and may not be sent outside Navistar, Inc. or reproduced without permission from Corporate Technical
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NAVISTARMPAPSDT152017TESTFORHOSEINSERTIONFORCEPDF

链接地址:http://www.mydoc123.com/p-962919.html