NASA UFGS-42 23 13 00 40-2011 PROCESS CONDENSERS《加工冷凝器》.pdf
《NASA UFGS-42 23 13 00 40-2011 PROCESS CONDENSERS《加工冷凝器》.pdf》由会员分享,可在线阅读,更多相关《NASA UFGS-42 23 13 00 40-2011 PROCESS CONDENSERS《加工冷凝器》.pdf(11页珍藏版)》请在麦多课文档分享上搜索。
1、*USACE / NAVFAC / AFCESA / NASA UFGS-42 23 13.00 40 (February 2011)-Preparing Activity: NASA SupersedingUFGS-42 23 13 (May 2010)UNIFIED FACILITIES GUIDE SPECIFICATIONSReferences are in agreement with UMRL dated January 2011*SECTION TABLE OF CONTENTSDIVISION 42 - PROCESS HEATING, COOLING, AND DRYING
2、EQUIPMENTSECTION 42 23 13.00 40PROCESS CONDENSERS02/11PART 1 GENERAL1.1 REFERENCES1.2 SYSTEM DESCRIPTION1.3 SUBMITTALS1.4 QUALITY ASSURANCEPART 2 PRODUCTS2.1 AIR-COOLED CONDENSER PACKAGE2.2 FANS AND DRIVES2.3 MOTORS2.4 REFRIGERANT-CONTAINING COMPONENTS2.5 CONDENSING PRESSURE CONTROL2.6 CASING2.7 CON
3、TROL PANEL2.8 VIBRATION ISOLATIONPART 3 EXECUTION3.1 INSTALLATION3.2 OPERATION AND MAINTENANCE- End of Section Table of Contents -SECTION 42 23 13.00 40 Page 1Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-*USACE / NAVFAC / AFCESA / NASA UFGS-42 23
4、13.00 40 (February 2011)-Preparing Activity: NASA SupersedingUFGS-42 23 13 (May 2010)UNIFIED FACILITIES GUIDE SPECIFICATIONSReferences are in agreement with UMRL dated January 2011*SECTION 42 23 13.00 40PROCESS CONDENSERS02/11*NOTE: This specification covers the requirements for remote air-cooled co
5、ndensers for processes.Edit this guide specification for project specific requirements by adding, deleting, or revising text. For bracketed items, choose applicable items(s) or insert appropriate information.Remove information and requirements not required in respective project, whether or not brack
6、ets are present.Comments, suggestions and recommended changes for this guide specification are welcome and should be submitted as a Criteria Change Request (CCR).*PART 1 GENERAL1.1 REFERENCES*NOTE: This paragraph is used to list the publications cited in the text of the guide specification. The publ
7、ications are referred to in the text by basic designation only and listed in this paragraph by organization, designation, date, and title.Use the Reference Wizards Check Reference feature when you add a RID outside of the Sections Reference Article to automatically place the reference in the Referen
8、ce Article. Also use the Reference Wizards Check Reference feature to update the issue dates.References not used in the text will automatically be deleted from this section of the project specification when you choose to reconcile references in the publish print process.*SECTION 42 23 13.00 40 Page
9、2Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text by the basic designation only.AIR-CONDITIONING, HEATING AND RE
10、FRIGERATION INSTITUTE (AHRI)ANSI/AHRI 460 (2005) Performance Rating of Remote Mechanical-Draft Air-Cooled Refrigerant CondensersAMERICAN SOCIETY OF HEATING, REFRIGERATING AND AIR-CONDITIONING ENGINEERS (ASHRAE)ANSI/ASHRAE 15 Addenda a, b, c, d, e, f, g, h, and i ) ANSI/ASHRAE Standard 15-Safety Stan
11、dard for Refrigeration Systems and ANSI/ASHRAE Standard 34-Designation and Safety Classification of RefrigerantsASHRAE 23 (2005) Methods of Testing for Rating Positive Displacement Refrigerant Compressors and Condensing UnitsASHRAE EQUIP IP HDBK (2008; Errata 1 2010) Handbook, HVAC Systems and Equip
12、ment (IP Edition)ASHRAE EQUIP SI HDBK (2008; Errata 1 2010) Handbook, HVAC Systems and Equipment (SI Edition)ASTM INTERNATIONAL (ASTM)ASTM A 653/A 653M (2009a) Standard Specification for Steel Sheet, Zinc-Coated (Galvanized) or Zinc-Iron Alloy-Coated (Galvannealed) by the Hot-Dip ProcessASTM A 90/A
13、90M (2009) Standard Test Method for Weight Mass of Coating on Iron and Steel Articles with Zinc or Zinc-Alloy CoatingsINTERNATIONAL ORGANIZATION FOR STANDARDIZATION (ISO)ISO 1940-1 (2003; Cor 2005) Mechanical Vibration - Balance Quality Requirements for Rotors in a Constant (Rigid) State - Part 1: S
14、pecification and Verification of BalanceNATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION (NEMA)NEMA 250 (2008) Enclosures for Electrical Equipment (1000 Volts Maximum)NEMA MG 1 (2009) Motors and GeneratorsNATIONAL FIRE PROTECTION ASSOCIATION (NFPA)NFPA 70 (2011) National Electrical CodeSECTION 42 23 13
15、.00 40 Page 3Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-SOCIETY OF AUTOMOTIVE ENGINEERS INTERNATIONAL (SAE)SAE J636 (1992; R 2001) V-Belts and PulleysUNDERWRITERS LABORATORIES (UL)UL 1995 (2005; Reprint Jul 2009) Heating and Cooling EquipmentUL
16、207 (2009) Refrigerant-Containing Components and Accessories, Nonelectrical1.2 SYSTEM DESCRIPTION*NOTE: If Section 23 00 00 AIR SUPPLY, DISTRIBUTION, VENTILATION, AND EXHAUST SYSTEMS is not included in the project specification, applicable requirements therefrom should be inserted and the following
17、paragraph deleted.Include in drawings or schedule total heat rejection capacity, capacity conditions, coil circuits, and control diagrams.*Section 23 00 00 AIR SUPPLY, DISTRIBUTION, VENTILATION, AND EXHAUST SYSTEMS applies to work specified in this section.Ensure results of Contractors survey of exi
18、sting conditions include features of existing structures and facilities within and adjacent to the jobsite. Commencement of work constitutes acceptance of existing conditions.Submit manufacturers catalog data for the following items, including the manufacturers standard color selections and finishes
19、 for condensers within manufacturers standard color chart:a. Air-cooled condenserb. Motorsc. Control paneld. Refrigerant-containing componentse. Fans and drivesf. Condensing pressure controlg. Casingh. Vibration isolationi. Spare partsSubmit material, equipment, and fixture lists or air-cooled conde
20、nser units including manufacturers style or catalog numbers, specification and drawing reference numbers, warranty information, and fabrication site SECTION 42 23 13.00 40 Page 4Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-information.Submit contr
21、ol diagrams for air-cooled condenser units showing the physical and functional relationship of equipment. Show size, type, and capacity of the system on electrical diagrams.Submit design analysis and calculations for air-cooled condensers indicating the manufacturers recommended wattage horsepower r
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NASAUFGS42231300402011PROCESSCONDENSERS 加工 冷凝器 PDF

链接地址:http://www.mydoc123.com/p-836612.html