NACE SP0177-2014 Mitigation of Alternating Current and Lightning Effects on Metallic Structures and Corrosion Control Systems (Item No 21021).pdf
《NACE SP0177-2014 Mitigation of Alternating Current and Lightning Effects on Metallic Structures and Corrosion Control Systems (Item No 21021).pdf》由会员分享,可在线阅读,更多相关《NACE SP0177-2014 Mitigation of Alternating Current and Lightning Effects on Metallic Structures and Corrosion Control Systems (Item No 21021).pdf(28页珍藏版)》请在麦多课文档分享上搜索。
1、 Mitigation of Alternating Current and Lightning Effects on Metallic Structures and Corrosion Control Systems This NACE International standard represents a consensus of those individual members who have reviewed this document, its scope, and provisions. Its acceptance does not in any respect preclud
2、e anyone, whether he or she has adopted the standard or not, from manufacturing, marketing, purchasing, or using products, processes, or procedures not in conformance with this standard. Nothing contained in this NACE standard is to be construed as granting any right, by implication or otherwise, to
3、 manufacture, sell, or use in connection with any method, apparatus, or product covered by letters patent, or as indemnifying or protecting anyone against liability for infringement of letters patent. This standard represents minimum requirements and should in no way be interpreted as a restriction
4、on the use of better procedures or materials. Neither is this standard intended to apply in all cases relating to the subject. Unpredictable circumstances may negate the usefulness of this standard in specific instances. NACE assumes no responsibility for the interpretation or use of this standard b
5、y other parties and accepts responsibility for only those official NACE interpretations issued by NACE in accordance with its governing procedures and policies which preclude the issuance of interpretations by individual volunteers. Users of this NACE standard are responsible for reviewing appropria
6、te health, safety, environmental, and regulatory documents and for determining their applicability in relation to this standard prior to its use. This NACE standard may not necessarily address all potential health and safety problems or environmental hazards associated with the use of materials, equ
7、ipment, and/or operations detailed or referred to within this standard. Users of this NACE standard are also responsible for establishing appropriate health, safety, and environmental protection practices, in consultation with appropriate regulatory authorities if necessary, to achieve compliance wi
8、th any existing applicable regulatory requirements prior to the use of this standard. CAUTIONARY NOTICE: NACE standards are subject to periodic review, and may be revised or withdrawn at any time in accordance with NACE technical committee procedures. NACE requires that action be taken to reaffirm,
9、revise, or withdraw this standard no later than five years from the date of initial publication and subsequently from the date of each reaffirmation or revision. The user is cautioned to obtain the latest edition. Purchasers of NACE standards may receive current information on all standards and othe
10、r NACE publications by contacting the NACE FirstService Department, 1440 South Creek Dr., Houston, TX 77084-4906 (telephone +1 281-228-6200). Revised 2014-03-08 Revised 2007-06-22 Reaffirmed 2000-09-19 Revised March 1995 Revised July 1983 Approved July 1977 NACE International 1440 South Creek Drive
11、Houston, Texas 77084-4906 + 1 281-228-6200 ISBN 1-57590-116-1 2014, NACE International SP0177-2014 (formerly RP0177) Item No. 21021 SP0177-2014 NACE International i _ Foreword This standard practice presents guidelines and procedures for use during design, construction, operation, and maintenance of
12、 metallic structures and corrosion control systems used to mitigate the effects of lightning and alternating current (AC) power transmission systems. This standard is not intended to supersede or replace existing electrical safety standards. As shared right-of-way and utility corridor practices beco
13、me more common, AC influence on adjacent metallic structures has greater significance, and personnel safety becomes of greater concern. This standard addresses problems primarily caused by proximity of metallic structures to AC-powered transmission systems. The hazards of lightning and AC effects on
14、 aboveground pipelines, while strung along the right-of-way prior to installation in the ground, are of particular importance to pipeline construction crews. The effects of AC power lines on buried pipelines are of particular concern to operators of aboveground appurtenances and cathodic protection
15、(CP) testers, CP designers, safety engineers, as well as maintenance personnel working on the pipeline. Some controversy arose in the 1995 issue of this standard regarding the shock hazard stated in Section 5, Paragraph 5.2.1.1 and elsewhere in this standard. The reason for a more conservative value
16、 is that early work by George Bodier1at Columbia University and by other investigators has shown that the average hand-to-hand or hand-to-foot resistance for an adult male human body can range between 600 ohms and 10,000 ohms. A reasonable safe value for the purpose of estimating body currents is 1,
17、500 ohms hand-to-hand or hand-to-foot. In other work by C.F. Dalziel2on muscular contraction, the inability to release contact occurs in the range of 6 to 20 mA for adult males. Ten mA hand-to-hand or hand-to-foot is generally established as the absolute maximum safe let-go current. Conservative des
18、ign uses an even lower value. Fifteen volts of AC impressed across a 1,500 ohm load would yield a current flow of 10 mA; thus, the criterion within this standard is set at 15 volts. Prudent design would suggest an even lower value under certain circumstances. Many are now concerned with AC corrosion
19、 on buried pipelines adjacent to or near overhead electric transmission towers. This subject is not quite fully understood, nor is there an industry consensus on this subject. There are reported incidents of AC corrosion on buried pipelines under specific conditions, and there are also many case his
20、tories of pipelines operating under the influence of induced AC for many years without any reports of AC corrosion. The members of NACE Task Group (TG) 025 agreed that criteria for AC corrosion control should not be included in this standard. However, the mitigation measures implemented for safety a
21、nd system protection, as outlined in this standard, may also be used for AC corrosion control. This standard was originally published in July 1977 by Unit Committee T-10B on Interference Problems and was technically revised in 1983 and 1995, and reaffirmed in 2000 by T-10B. NACE continues to recogni
22、ze the need for a standard on this subject. Future development and field experience should provide additional information, procedures, and devices for Specific Technology Group (STG) 05, “Cathodic/Anodic Protection,” to consider in future revisions of this standard. This standard was revised in 2007
23、 and 2014 by TG 025, “Alternating Current (AC) Power Systems, Adjacent: Corrosion Control and Related Safety Procedures to Mitigate the Effects.” It is sponsored by STG 03, “Coatings and Linings, ProtectiveImmersion and Buried Service,” and STG 35, “Pipelines, Tanks, and Well Casings.” This standard
24、 is issued by NACE under the auspices of STG 05. In NACE standards, the terms shall, must, should, and may are used in accordance with the definitions of these terms in the NACE Publications Style Manual. The terms shall and must are used to state a requirement, and are considered mandatory. The ter
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NACESP01772014MITIGATIONOFALTERNATINGCURRENTANDLIGHTNINGEFFECTSONMETALLICSTRUCTURESANDCORROSIONCONTROLSYSTEMSITEMNO21021PDF

链接地址:http://www.mydoc123.com/p-835805.html